INTRODUCTION: The purpose of this study was to compare the in vitro torsional stress characteristics of Twisted Files (TFs; SybronEndo, Orange, CA) with 2 milled files of a similar cross-section: EndoSequence (Brasseler USA, Savannah, GA) and ProFile Vortex (DENTSPLY Tulsa Dental, Tulsa, OK).
METHODS: File sizes of 25/.06 and 30/.06 from the 3 file types were compared (n = 20/group). Torsional stress resistance was evaluated by measuring the torque in grams per centimeters and the angle of rotation (°) required for instrument separation with the use of a torsiometer instrument. The fractured files were examined using a scanning electron microscope to look at deformation and fracture surface characteristics. The data were analyzed with analysis of variance to determine statistical differences.
RESULTS: The 3 file types showed a statistically significant difference in both the maximum torsional stress and the angle of rotation before failure. TFs displayed the least amount of torsional stress resistance and the highest angle of rotation. The 30/.06 size files of all 3 types withstood more torsional stress than the size 25/06 files of the same type. Within each file design, there was not a statistically significant difference in angular rotation between the 25/.06 and 30/.06 groups. The scanning electron microscopic analysis of all 3 file types revealed dimpling near the center of rotation on the fractured surface indicative of torsional stress.
CONCLUSIONS: The novel techniques used in manufacturing TFs do not make them more resistant to torsional stress as compared with milled nickel-titanium endodontic files of a similar cross-sectional design.
Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22794218     DOI: 10.1016/j.joen.2012.04.022

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  12 in total

1.  Deformations and cyclic fatigue resistance of nickel-titanium instruments inside a sequence.

Authors:  Gianluca Gambarini; Gianluca Plotino; Lucila Piasecki; Dina Al-Sudani; Luca Testarelli; Gianpaolo Sannino
Journal:  Ann Stomatol (Roma)       Date:  2015-05-18

2.  Differences in torsional performance of single- and multiple-instrument rotary systems for glide path preparation.

Authors:  Ana Arias; Rupinderpal Singh; Ove A Peters
Journal:  Odontology       Date:  2015-02-21       Impact factor: 2.634

3.  Effect of autoclave sterilization on cyclic fatigue and torsional fracture resistance of NiTi rotary instruments.

Authors:  Wooyoung Kim; Soram Oh; Gil-Joo Ryu; Tae-Hwan Kim; Sung-Jae Kim; Dong-Hyung Kim; Bin-Na Lee; Kee-Yeon Kum; Seok Woo Chang; Ji-Hyun Jang
Journal:  Odontology       Date:  2019-09-11       Impact factor: 2.634

4.  Mechanical and Metallurgical Properties of Various Nickel-Titanium Rotary Instruments.

Authors:  Kyu-Sang Shim; Soram Oh; KeeYeon Kum; Yu-Chan Kim; Kwang-Koo Jee; Seok Woo Chang
Journal:  Biomed Res Int       Date:  2017-11-28       Impact factor: 3.411

5.  Effect of surface treatment on the mechanical properties of nickel-titanium files with a similar cross-section.

Authors:  Sang Won Kwak; Joo Yeong Lee; Hye-Jin Goo; Hyeon-Cheol Kim
Journal:  Restor Dent Endod       Date:  2017-06-28

6.  Comparison of cleaning efficiency and deformation characteristics of Twisted File and ProTaper rotary instruments.

Authors:  Hang Li; Chenzheng Zhang; Qing Li; Changning Wang; Yaling Song
Journal:  Eur J Dent       Date:  2014-04

7.  In vitro investigation of the cleaning efficacy, shaping ability, preparation time and file deformation of continuous rotary, reciprocating rotary and manual instrumentations in primary molars.

Authors:  Nahid Ramazani; Abbas Mohammadi; Foroogh Amirabadi; Mohsen Ramazani; Farzane Ehsani
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2016-03-16

8.  Resistance to torsional failure and cyclic fatigue resistance of ProTaper Next, WaveOne, and Mtwo files in continuous and reciprocating motion: An in vitro study.

Authors:  N O Varghese; Rajesh Pillai; U-Nu Sujathen; Shan Sainudeen; Abe Antony; Sinju Paul
Journal:  J Conserv Dent       Date:  2016 May-Jun

9.  Effects of R-Phase on Mechanical Responses of a Nickel-Titanium Endodontic Instrument: Structural Characterization and Finite Element Analysis.

Authors:  Leandro de Arruda Santos; Pedro Damas Resende; Maria Guiomar de Azevedo Bahia; Vicente Tadeu Lopes Buono
Journal:  ScientificWorldJournal       Date:  2016-05-22

10.  Cyclic Fatigue Resistance of Mtwo Rotary Instruments with two Different Instrumentation Techniques.

Authors:  Sílvio Emanuel Acioly Conrado de Menezes; Shirley Machado Batista; Diego Felipe Brandão de Magalhães; de Albuquerque Diana Santana; Gabriela Queiroz de Melo Monteiro
Journal:  Iran Endod J       Date:  2018
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.