Literature DB >> 22790529

Aseptic tibial debonding as a cause of early failure in a modern total knee arthroplasty design.

Diren Arsoy1, Mark W Pagnano, David G Lewallen, Arlen D Hanssen, Rafael J Sierra.   

Abstract

BACKGROUND: We observed isolated tibial component debonding from the cement in one modern primary TKA design (NexGen LPS 3° tibial tray; Zimmer, Warsaw, IN, USA). This failure mechanism is sparsely reported in the literature. QUESTIONS/PURPOSES: We (1) assessed survivorship of this tibial tray with special emphasis on debonding; (2) described clinical and radiographic features associated with tibial failure; and (3) compared patient and radiographic features of the failures with a matched cohort.
METHODS: A total of 1337 primary TKAs were performed with a cemented NexGen LPS 3° tibial tray over an 11-year period. Twenty-five knees (1.9%) were revised for tibial debonding. BMI and radiographic alignment in the tibial debonding group were compared with a matched control group. Implant survivorship was assessed using tibial debonding as the end point.
RESULTS: Survival free of revision from tibial debonding was 100% at 1 year and 97.8% at 5 years. The tibial failures shared a typical radiographic pattern with debonding at the cement-implant interface and subsidence into varus and flexion. We found no link between limb alignment or individual component alignment and failure because 22 of the 25 failures occurred in well-aligned knees.
CONCLUSIONS: Our standardized followup of patients undergoing TKA at routine intervals allowed us to discover a higher rate of revision resulting from tibial debonding. We have discontinued the use of this particular tibial tray for primary TKA and surveillance for patients undergoing TKA continues to be warranted.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 22790529      PMCID: PMC3528903          DOI: 10.1007/s11999-012-2467-4

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  31 in total

1.  Tibial component failure mechanisms in total knee arthroplasty.

Authors:  Michael E Berend; Merrill A Ritter; John B Meding; Philip M Faris; E Michael Keating; Ryan Redelman; Gregory W Faris; Kenneth E Davis
Journal:  Clin Orthop Relat Res       Date:  2004-11       Impact factor: 4.176

2.  Prospective, randomized study between Insall-Burstein II and NexGen legacy with a minimum 9-year follow-up.

Authors:  Kwang-Jun Oh; Stuart B Goodman; Jae-Hyuk Yang
Journal:  J Arthroplasty       Date:  2011-02-04       Impact factor: 4.757

3.  Geometric total knee arthroplasty. A two-year follow-up study.

Authors:  M D Skolnick; M B Coventry; D M Ilstrup
Journal:  J Bone Joint Surg Am       Date:  1976-09       Impact factor: 5.284

4.  Rationale of the Knee Society clinical rating system.

Authors:  J N Insall; L D Dorr; R D Scott; W N Scott
Journal:  Clin Orthop Relat Res       Date:  1989-11       Impact factor: 4.176

5.  Radiographic assessment of knee alignment after total knee arthroplasty.

Authors:  T L Petersen; G A Engh
Journal:  J Arthroplasty       Date:  1988       Impact factor: 4.757

6.  Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002.

Authors:  Steven Kurtz; Fionna Mowat; Kevin Ong; Nathan Chan; Edmund Lau; Michael Halpern
Journal:  J Bone Joint Surg Am       Date:  2005-07       Impact factor: 5.284

7.  Revision rates after knee replacement in the United States.

Authors:  D A Heck; C A Melfi; L A Mamlin; B P Katz; D S Arthur; R S Dittus; D A Freund
Journal:  Med Care       Date:  1998-05       Impact factor: 2.983

8.  UCI total knee replacement. A follow-up study.

Authors:  L R Hamilton
Journal:  J Bone Joint Surg Am       Date:  1982-06       Impact factor: 5.284

9.  Failure of total knee arthroplasty due to loosening and deformation of the tibial component.

Authors:  P Ducheyne; A Kagan; J A Lacey
Journal:  J Bone Joint Surg Am       Date:  1978-04       Impact factor: 5.284

10.  The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement. Results at five to fourteen years.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  J Bone Joint Surg Am       Date:  2004-03       Impact factor: 5.284

View more
  18 in total

1.  Comparison of different cement application techniques for tibial component fixation in TKA.

Authors:  Ulf J Schlegel; Nicholas E Bishop; Klaus Püschel; Michael M Morlock; Katrin Nagel
Journal:  Int Orthop       Date:  2014-08-01       Impact factor: 3.075

Review 2.  Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms.

Authors:  J Gallo; S B Goodman; Y T Konttinen; M A Wimmer; M Holinka
Journal:  Acta Biomater       Date:  2013-05-10       Impact factor: 8.947

3.  Experimental and computational micromechanics at the tibial cement-trabeculae interface.

Authors:  Priyanka Srinivasan; Mark A Miller; Nico Verdonschot; Kenneth A Mann; Dennis Janssen
Journal:  J Biomech       Date:  2016-04-02       Impact factor: 2.712

4.  Do Metaphyseal Cones and Stems Provide Any Biomechanical Advantage for Moderate Contained Tibial Defects in Revision TKA? A Finite-Element Analysis Based on a Cadaver Model.

Authors:  Fernando J Quevedo González; Kathleen N Meyers; Nicholas Schraut; Kapil G Mehrotra; Joseph D Lipman; Timothy M Wright; Michael P Ast
Journal:  Clin Orthop Relat Res       Date:  2021-11-01       Impact factor: 4.755

5.  Does Knee Prosthesis Survivorship Improve When Implant Designs Change? Findings from the Australian Orthopaedic Association National Joint Replacement Registry.

Authors:  Peter L Lewis; Stephen E Graves; Richard N de Steiger; David G Campbell; Yi Peng; Alesha Hatton; Michelle Lorimer
Journal:  Clin Orthop Relat Res       Date:  2020-06       Impact factor: 4.755

6.  The effect of tourniquet usage on cement penetration in total knee arthroplasty: A prospective randomized study of 3 methods.

Authors:  Okan Ozkunt; Kerim Sariyilmaz; Halil Can Gemalmaz; Fatih Dikici
Journal:  Medicine (Baltimore)       Date:  2018-01       Impact factor: 1.889

7.  Micrometer-Sized Titanium Particles Induce Aseptic Loosening in Rabbit Knee.

Authors:  Hao Xu; Cui-Cui Guo; Zheng-Yu Gao; Chang-Yao Wang; Hai-Ning Zhang; Cheng-Yu Lv; Zi-Yan Yin; Ying-Zhen Wang
Journal:  Biomed Res Int       Date:  2018-02-13       Impact factor: 3.411

8.  Radiolucent lines are decreased at 3 years following total knee arthroplasty using trabecular metal tibial components.

Authors:  Hirotaka Mutsuzaki; Arata Watanabe; Tomonori Kinugasa; Kotaro Ikeda
Journal:  J Int Med Res       Date:  2018-03-20       Impact factor: 1.671

9.  Reliability of two different measuring techniques with computer tomography for penetration and distribution of cement in the proximal tibia after total knee arthroplasty.

Authors:  Hennie Verburg; Linda van Zeeland Koobs; Dieu Donné Niesten; Peter Pilot; Nina Mathijssen
Journal:  BMC Musculoskelet Disord       Date:  2020-06-12       Impact factor: 2.362

10.  A randomized controlled trial comparing tibial migration of the ATTUNE cemented cruciate-retaining knee prosthesis with the PFC-sigma design.

Authors:  Bart L Kaptein; Peter den Hollander; Bregje Thomassen; Martha Fiocco; Rob G H H Nelissen
Journal:  Bone Joint J       Date:  2020-09       Impact factor: 5.082

View more