Fluid shear stress in trabecular bone marrow due to low-magnitude high-frequency vibration.

Thomas R Coughlin1, Glen L Niebur.   

Abstract

Low-magnitude high-frequency (LMHF) loading has recently received attention for its anabolic effect on bone. The mechanism of transmission of the anabolic signal is not fully understood, but evidence indicates that it is not dependent on bone matrix strain. One possible source of signaling is mechanostimulation of the cells in the bone marrow. We hypothesized that the magnitude of the fluid shear stress in the marrow during LMHF loading is in the mechanostimulatory range. As such, the goal of this study was to determine the range of shear stress in the marrow during LMHF vibration. The shear stress was estimated from computational models, and its dependence on bone density, architecture, permeability, marrow viscosity, vibration amplitude and vibration frequency were examined. Three-dimensional finite element models of five trabecular bone samples from different anatomic sites were constructed, and a sinusoidal velocity profile was applied to the models. In human bone models during axial vibration at an amplitude of 1 g, more than 75% of the marrow experienced shear stress greater than 0.5Pa. In comparison, in vitro studies indicate that fluid induced shear stress in the range of 0.5 to 2.0Pa is anabolic to a variety of cells in the marrow. Shear stress at the bone-marrow interface was as high as 5.0Pa. Thus, osteoblasts and bone lining cells that are thought to reside on the endosteal surfaces may experience very high shear stress during LMHF loading. However, a more complete understanding of the location of the various cell populations in the marrow is needed to quantify the effects on specific cell types. This study suggests the shear stress within bone marrow in real trabecular architecture during LMHF vibration could provide the mechanical signal to marrow cells that leads to bone anabolism.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22784651     DOI: 10.1016/j.jbiomech.2012.06.020

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  27 in total

1.  Primary cilia exist in a small fraction of cells in trabecular bone and marrow.

Authors:  Thomas R Coughlin; Muriel Voisin; Mitchell B Schaffler; Glen L Niebur; Laoise M McNamara
Journal:  Calcif Tissue Int       Date:  2014-11-15       Impact factor: 4.333

Review 2.  Towards rationally designed biomanufacturing of therapeutic extracellular vesicles: impact of the bioproduction microenvironment.

Authors:  Divya B Patel; Marco Santoro; Louis J Born; John P Fisher; Steven M Jay
Journal:  Biotechnol Adv       Date:  2018-09-12       Impact factor: 14.227

Review 3.  Combating osteoporosis and obesity with exercise: leveraging cell mechanosensitivity.

Authors:  Gabriel M Pagnotti; Maya Styner; Gunes Uzer; Vihitaben S Patel; Laura E Wright; Kirsten K Ness; Theresa A Guise; Janet Rubin; Clinton T Rubin
Journal:  Nat Rev Endocrinol       Date:  2019-06       Impact factor: 43.330

Review 4.  Biophysical regulation of stem cell differentiation.

Authors:  Peter M Govey; Alayna E Loiselle; Henry J Donahue
Journal:  Curr Osteoporos Rep       Date:  2013-06       Impact factor: 5.096

5.  Osteoblast-derived paracrine factors regulate angiogenesis in response to mechanical stimulation.

Authors:  Chao Liu; Xin Cui; Thomas M Ackermann; Vittoria Flamini; Weiqiang Chen; Alesha B Castillo
Journal:  Integr Biol (Camb)       Date:  2016-07-11       Impact factor: 2.192

6.  Cell Mechanosensitivity to Extremely Low-Magnitude Signals Is Enabled by a LINCed Nucleus.

Authors:  Gunes Uzer; William R Thompson; Buer Sen; Zhihui Xie; Sherwin S Yen; Sean Miller; Guniz Bas; Maya Styner; Clinton T Rubin; Stefan Judex; Keith Burridge; Janet Rubin
Journal:  Stem Cells       Date:  2015-06       Impact factor: 6.277

7.  Mechanical Loading Promotes the Expansion of Primitive Osteoprogenitors and Organizes Matrix and Vascular Morphology in Long Bone Defects.

Authors:  Chao Liu; Pamela Cabahug-Zuckerman; Christopher Stubbs; Martin Pendola; Cinyee Cai; Kenneth A Mann; Alesha B Castillo
Journal:  J Bone Miner Res       Date:  2019-02-20       Impact factor: 6.741

8.  Fluid-structure interactions in micro-interlocked regions of the cement-bone interface.

Authors:  Kenneth A Mann; Mark A Miller
Journal:  Comput Methods Biomech Biomed Engin       Date:  2013-03-12       Impact factor: 1.763

9.  The potential benefits and inherent risks of vibration as a non-drug therapy for the prevention and treatment of osteoporosis.

Authors:  M Ete Chan; Gunes Uzer; Clinton T Rubin
Journal:  Curr Osteoporos Rep       Date:  2013-03       Impact factor: 5.096

Review 10.  Biomechanical forces in the skeleton and their relevance to bone metastasis: biology and engineering considerations.

Authors:  Maureen E Lynch; Claudia Fischbach
Journal:  Adv Drug Deliv Rev       Date:  2014-08-29       Impact factor: 15.470

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.