Literature DB >> 22767168

Anterior segment biometry: a study and review of resolution and repeatability data.

Dan Z Reinstein1, Marine Gobbe, Timothy J Archer.   

Abstract

PURPOSE: To obtain comparable resolution and repeatability data for a selection of anterior segment imaging devices.
METHODS: A standard letter of request was sent in May 2008 to each device manufacturer requesting resolution and repeatability data for its device to be provided according to specific definitions and protocol; if this was not already published in the peer-reviewed domain, compliant raw data were required. Where applicable, repeatability data were reported for corneal vertex corneal thickness; epithelial and flap thickness; minimum corneal thickness; corneal, epithelial and flap thickness mapping for the central 6-mm diameter; minimum residual stromal thickness; angle-to-angle diameter; sulcus-to-sulcus diameter; and anterior chamber depth. To summarize published repeatability data, a complete review of the peer-reviewed literature waas performed.
RESULTS: Nine of the 13 manufacturers contacted agreed to take part and provided the data requested: Pentacam HD (Oculus Optikgeräte GmbH), Galilei (Ziemer), Visante OCT (Carl Zeiss Meditec), SL-OCT (Haag-Streit), RTVue (Optovue), Artemis (ArcScan), Vumax (Sonomed), HiScan (Opticon), and Eye Cubed (Ellex/Innovative). Only one (Carl Zeiss Meditec) of 9 manufacturers was able to provide the data directly upon request, without performing a prospective study. Five of the 9 manufacturers were able to provide a complete set of repeatability data for all parameters measurable with their device; the remaining 4 manufacturers admitted that repeatability of some parameters was unknown.
CONCLUSIONS: Both literature and manufacturers' data on file were lacking and required the study to be performed. This report provides an imperfect, but most comprehensive to date, resolution and repeatability data review of biometric devices intended for surgical planning. Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Year:  2012        PMID: 22767168     DOI: 10.3928/1081597X-20120620-02

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  9 in total

1.  New Details of the Human Corneal Limbus Revealed With Second Harmonic Generation Imaging.

Authors:  Choul Yong Park; Jimmy K Lee; Cheng Zhang; Roy S Chuck
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-09       Impact factor: 4.799

2.  Comparison of ultrasound biomicroscopy and spectral-domain anterior segment optical coherence tomography in evaluation of anterior segment after laser peripheral iridotomy.

Authors:  Xiao-Yun Ma; Dan Zhu; Jun Zou; Wen-Jie Zhang; Yi-Lin Cao
Journal:  Int J Ophthalmol       Date:  2016-03-18       Impact factor: 1.779

3.  Comparison of objective and subjective refractive surgery screening parameters between regular and high-resolution Scheimpflug imaging devices.

Authors:  J Bradley Randleman; Jihan Akhtar; Michael J Lynn; Renato Ambrósio; William J Dupps; Ronald R Krueger; Stephen D Klyce
Journal:  J Cataract Refract Surg       Date:  2014-12-20       Impact factor: 3.351

4.  Predictors of Intraocular Pressure After Phacoemulsification in Primary Open-Angle Glaucoma Eyes with Wide Versus Narrower Angles (An American Ophthalmological Society Thesis).

Authors:  Shan C Lin; Marisse Masis; Travis C Porco; Louis R Pasquale
Journal:  Trans Am Ophthalmol Soc       Date:  2017-10-23

5.  Accuracy of OCT-derived net corneal astigmatism measurement.

Authors:  Clara Llorens-Quintana; Elias Pavlatos; Omkar Thaware; Seema Gupta; Daniel Gradin; Denzil Romfh; Yan Li; David Huang
Journal:  J Cataract Refract Surg       Date:  2022-03-01       Impact factor: 3.528

6.  Fast segmentation of anterior segment optical coherence tomography images using graph cut.

Authors:  Dominic Williams; Yalin Zheng; Fangjun Bao; Ahmed Elsheikh
Journal:  Eye Vis (Lond)       Date:  2015-01-22

Review 7.  Cornea and anterior eye assessment with slit lamp biomicroscopy, specular microscopy, confocal microscopy, and ultrasound biomicroscopy.

Authors:  Raul Martin
Journal:  Indian J Ophthalmol       Date:  2018-02       Impact factor: 1.848

8.  Comparison of Color Light-Emitting Diode Corneal Topographer and Dual Rotating Scheimpflug-Placido Topographer.

Authors:  Jae Hyuck Lee; Yong Woo Lee; Jong Soo Lee; Michael C Knorz; Gerd U Auffarth; Chul Young Choi
Journal:  J Ophthalmol       Date:  2018-12-27       Impact factor: 1.909

Review 9.  Biometric Measurement of Anterior Segment: A Review.

Authors:  Bin Liu; Chengwei Kang; Fengzhou Fang
Journal:  Sensors (Basel)       Date:  2020-07-31       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.