Literature DB >> 22762154

Accuracy of enhancement filters in measuring in vitro peri-implant bone level.

Sergio Lins de Azevedo Vaz1, Frederico Sampaio Neves, Evandro Portela Figueirêdo, Francisco Haiter-Neto, Paulo Sérgio Flores Campos.   

Abstract

OBJECTIVES: To identify the accuracy of enhancement filters of an intraoral phosphor-plate system for measuring the simulated peri-implant bone level.
MATERIALS AND METHODS: A total of 20 titanium implants (Titamax(®) ) were placed into six fragments of bovine ribs and defects simulating bone loss were created. Periapical radiographs were taken with a phosphor-plate system (Vista Scan(®) ) according to the paralleling standard technique, and nine enhancement filters were applied: fine, caries 1, caries 2, perio, endo, noise reduction, invert, emboss, and sculpture. The Friedman test compared the radiographic measurements of the defects to those obtained on the bovine ribs with a digital caliper. Intra- and interobserver agreement was calculated with the intra-class correlation coefficient (ICC).
RESULTS: The ICC values showed excellent intra- and interobserver agreement. The caries1, caries2, endo, and perio filters resulted on measurements statistically different from both the original images and the measurements of the digital caliper (P < 0.05). The other filters did not show statistically significant differences from the original images nor from the measurements of the digital caliper.
CONCLUSION: In addition to the original images, the fine and emboss filters resulted on the most precise measures. The caries1, caries2, endo, and perio filters were the less accurate for measuring the peri-implant bone level.
© 2012 John Wiley & Sons A/S.

Entities:  

Keywords:  alveolar bone loss; dental implants; digital dental radiography; peri-implantitis; radiographic image enhancement

Mesh:

Substances:

Year:  2012        PMID: 22762154     DOI: 10.1111/j.1600-0501.2012.02511.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  6 in total

1.  Imaging evaluating of the implant/bone interface-an in vitro radiographic study.

Authors:  Michele M Vidor; Gabriela S Liedke; Mariana B Vizzotto; Heraldo L D da Silveira; Priscila F da Silveira; Cristiano W Araujo; Heloisa E D da Silveira
Journal:  Dentomaxillofac Radiol       Date:  2017-03-28       Impact factor: 2.419

2.  Does dose optimisation in digital panoramic radiography affect diagnostic performance?

Authors:  Luciano Augusto Cano Martins; Danieli M Brasil; Laís A Forner; Cassiana Viccari; Francisco Haiter-Neto; Deborah Q Freitas; Matheus L Oliveira
Journal:  Clin Oral Investig       Date:  2020-08-26       Impact factor: 3.573

3.  The impact of digital filters on the diagnosis of simulated root resorptions in digital radiographic systems.

Authors:  Nicolly Oliveira-Santos; Hugo Gaêta-Araujo; Débora Costa Ruiz; Eduarda Helena Leandro Nascimento; Wilson Gustavo Cral; Christiano Oliveira-Santos; Francisco Carlos Groppo
Journal:  Clin Oral Investig       Date:  2022-03-10       Impact factor: 3.606

4.  Exploring digital filters for internal root resorption: how can we improve the diagnosis of small lesions?

Authors:  Priscila Fernanda da Silveira Tiecher; Nádia Assein Arús; Eduarda Adams Hilgert; Heloisa Emilia Dias da Silveira; Mathias Pante Fontana; Heraldo Luís Dias da Silveira; Mariana Boessio Vizzotto
Journal:  Dentomaxillofac Radiol       Date:  2021-11-23       Impact factor: 3.525

5.  The Effects of Imaging Enhancement Tools in the Detection of Horizontal Root Fractures.

Authors:  Mohammed Barayan; Ibrahim Nasseh; Hassem Geha; Marcel Noujeim
Journal:  J Clin Diagn Res       Date:  2017-08-01

6.  Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects.

Authors:  Seyed Jalal Pourhashemi; Zahra Ghoncheh; Mohammad Taghi Kiani; Raheleh Emami; Mohamad Javad Kharazifard
Journal:  J Dent (Tehran)       Date:  2015-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.