Literature DB >> 22750760

Improved precision of syndesmophyte measurement for the evaluation of ankylosing spondylitis using CT: a phantom and patient study.

Sovira Tan1, Jianhua Yao, Lawrence Yao, Michael M Ward.   

Abstract

Ankylosing spondylitis is a disease characterized by abnormal bone formation (syndesmophyte) at the margins of inter-vertebral disc spaces. Syndesmophyte growth is currently typically monitored by the visual inspection of radiographs. The limitations inherent to the modality (2D projection of a 3D object) and rater (qualitative human judgment) may compromise sensitivity. With newly available treatments, more precise measures of syndesmophytes are needed to determine whether treatment can slow rates of syndesmophyte growth. We previously presented a computer algorithm measuring syndesmophyte volumes and heights in the 3D space of CT scans. In this study, we present improvements to the original algorithm and evaluate the gain in precision as applied to an anthropomorphic vertebral phantom and patients. Each patient was scanned twice in one day, thus providing two syndesmophyte volume and height measures. The difference between those two measures (ideally zero) determines our algorithm's precision. The technical improvements to the algorithm decreased the mean volume difference (standard deviation) between scans from 3.01% (2.83%) to 1.31% (0.95%) and the mean height difference between scans from 3.16% (2.99%) to 1.56% (1.13%). The high precision of the improved algorithm holds promise for application to longitudinal clinical studies.

Entities:  

Mesh:

Year:  2012        PMID: 22750760      PMCID: PMC3427026          DOI: 10.1088/0031-9155/57/14/4683

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  15 in total

1.  Reducing inter-scanner variability of activation in a multicenter fMRI study: role of smoothness equalization.

Authors:  Lee Friedman; Gary H Glover; Diana Krenz; Vince Magnotta
Journal:  Neuroimage       Date:  2006-07-27       Impact factor: 6.556

2.  User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability.

Authors:  Paul A Yushkevich; Joseph Piven; Heather Cody Hazlett; Rachel Gimpel Smith; Sean Ho; James C Gee; Guido Gerig
Journal:  Neuroimage       Date:  2006-03-20       Impact factor: 6.556

3.  Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques.

Authors:  C C Glüer; G Blake; Y Lu; B A Blunt; M Jergas; H K Genant
Journal:  Osteoporos Int       Date:  1995       Impact factor: 4.507

4.  Surface-based registration accuracy of CT-based image-guided spine surgery.

Authors:  Yuichi Tamura; Nobuhiko Sugano; Toshihiko Sasama; Yoshinobu Sato; Shinichi Tamura; Kazuo Yonenobu; Hideki Yoshikawa; Takahiro Ochi
Journal:  Eur Spine J       Date:  2004-11-04       Impact factor: 3.134

5.  Radiographic findings following two years of infliximab therapy in patients with ankylosing spondylitis.

Authors:  Désirée van der Heijde; Robert Landewé; Xenofon Baraliakos; Harry Houben; Astrid van Tubergen; Paul Williamson; Weichun Xu; Daniel Baker; Neil Goldstein; Jürgen Braun
Journal:  Arthritis Rheum       Date:  2008-10

6.  Statistical validation of image segmentation quality based on a spatial overlap index.

Authors:  Kelly H Zou; Simon K Warfield; Aditya Bharatha; Clare M C Tempany; Michael R Kaus; Steven J Haker; William M Wells; Ferenc A Jolesz; Ron Kikinis
Journal:  Acad Radiol       Date:  2004-02       Impact factor: 3.173

7.  Radiographic progression of ankylosing spondylitis after up to two years of treatment with etanercept.

Authors:  D van der Heijde; R Landewé; S Einstein; P Ory; D Vosse; L Ni; S-L Lin; W Tsuji; J C Davis
Journal:  Arthritis Rheum       Date:  2008-05

Review 8.  Ankylosing spondylitis.

Authors:  Jürgen Braun; Joachim Sieper
Journal:  Lancet       Date:  2007-04-21       Impact factor: 79.321

9.  Computer aided evaluation of ankylosing spondylitis using high-resolution CT.

Authors:  Sovira Tan; Jianhua Yao; Michael M Ward; Lawrence Yao; Ronald M Summers
Journal:  IEEE Trans Med Imaging       Date:  2008-09       Impact factor: 10.048

10.  Semiautomated three-dimensional segmentation software to quantify carpal bone volume changes on wrist CT scans for arthritis assessment.

Authors:  J Duryea; M Magalnick; S Alli; L Yao; M Wilson; R Goldbach-Mansky
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

View more
  6 in total

1.  Dynamics of syndesmophyte growth in AS as measured by quantitative CT: heterogeneity within and among vertebral disc spaces.

Authors:  Sovira Tan; Jianhua Yao; John A Flynn; Lawrence Yao; Michael M Ward
Journal:  Rheumatology (Oxford)       Date:  2014-11-12       Impact factor: 7.580

2.  High precision semiautomated computed tomography measurement of lumbar disk and vertebral heights.

Authors:  Sovira Tan; Jianhua Yao; Lawrence Yao; Michael M Ward
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

3.  Quantitative syndesmophyte measurement in ankylosing spondylitis using CT: longitudinal validity and sensitivity to change over 2 years.

Authors:  Sovira Tan; Jianhua Yao; John A Flynn; Lawrence Yao; Michael M Ward
Journal:  Ann Rheum Dis       Date:  2013-12-02       Impact factor: 19.103

4.  Quantitative measurement of syndesmophyte volume and height in ankylosing spondylitis using CT.

Authors:  Sovira Tan; Jianhua Yao; John A Flynn; Lawrence Yao; Michael M Ward
Journal:  Ann Rheum Dis       Date:  2013-01-23       Impact factor: 19.103

5.  Spatial distribution of syndesmophytes along the vertebral rim in ankylosing spondylitis: preferential involvement of the posterolateral rim.

Authors:  Sovira Tan; Abhijit Dasgupta; Jianhua Yao; John A Flynn; Lawrence Yao; Michael M Ward
Journal:  Ann Rheum Dis       Date:  2016-01-21       Impact factor: 19.103

Review 6.  Better Quantification of Syndesmophyte Growth in Axial Spondyloarthritis.

Authors:  Michael M Ward; Sovira Tan
Journal:  Curr Rheumatol Rep       Date:  2018-06-21       Impact factor: 4.592

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.