Radiation dose estimations to the thorax using organ-based dose modulation.

Matthew P Lungren1, Terry T Yoshizumi, Samuel M Brady, Greta Toncheva, Colin Anderson-Evans, Carolyn Lowry, Xiaodong R Zhou, Donald Frush, Lynne M Hurwitz.   

Abstract

OBJECTIVE: The purpose of this study was to assess the radiation dose distribution and image quality for organ-based dose modulation during adult thoracic MDCT.
MATERIALS AND METHODS: Organ doses were measured using an anthropomorphic adult female phantom containing 30 metal oxide semiconductor field-effect transistor detectors on a dual-source MDCT scanner with two protocols: standard tube current modulation thoracic CT and organ-based dose modulation using a 120° radial arc. Radiochromic film measured the relative axial dose. Noise was measured to evaluate image quality. Breast tissue location across the anterior aspect of the thorax was retrospectively assessed in 100 consecutive thoracic MDCT examinations.
RESULTS: There was a 17-47% decrease (p = < 0.05) in anterior thoracic organ dose and a maximum 52% increase (p = < 0.05) in posterior thoracic organ dose using organ-based dose modulation compared with tube current modulation. Effective dose (SD) for tube current modulation and organ-based dose modulation were 5.25 ± 0.36 mSv and 4.42 ± 0.30 mSv, respectively. Radiochromic film analysis showed a 30% relative midline anterior-posterior gradient. There was no statistically significant difference in image noise. Adult female breast tissue was located within an average anterior angle of 155° (123-187°).
CONCLUSION: Organ-based dose modulation CT using an anterior 120° arc can reduce the organ dose in the anterior aspect of the thorax with a compensatory organ dose increase posteriorly without impairment of image quality. Laterally located breast tissue will have higher organ doses than medially located breast tissue when using organ-based dose modulation. The benefit of this dose reduction must be clinically determined on the basis of the relationship of the irradiated organs to the location of the prescribed radial arc used in organ-based dose modulation.

Entities:  

Mesh:

Year:  2012        PMID: 22733933     DOI: 10.2214/AJR.11.7798

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  14 in total

1.  Organ-based tube current modulation in a clinical context: Dose reduction may be largely overestimated in breast tissue.

Authors:  André Euler; Zsolt Szucs-Farkas; Anna L Falkowski; Nadine Kawel-Böhm; Luigia D'Errico; Sebastién Kopp; Jens Bremerich; Tilo Niemann
Journal:  Eur Radiol       Date:  2015-11-12       Impact factor: 5.315

2.  Diagnosing venous thromboembolism in pregnancy.

Authors:  Thomas Grüning; Rebecca E Mingo; Matthew G Gosling; Sally L Farrell; Brent E Drake; Robert J Loader; Richard D Riordan
Journal:  Br J Radiol       Date:  2016-04-08       Impact factor: 3.039

3.  Breast dose reduction with organ-based, wide-angle tube current modulated CT.

Authors:  Wanyi Fu; Gregory M Sturgeon; Greeshma Agasthya; William Paul Segars; Anuj J Kapadia; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-04

4.  Do we need 3D tube current modulation information for accurate organ dosimetry in chest CT? Protocols dose comparisons.

Authors:  Xochitl Lopez-Rendon; Guozhi Zhang; Walter Coudyzer; Wim Develter; Hilde Bosmans; Federica Zanca
Journal:  Eur Radiol       Date:  2017-05-19       Impact factor: 5.315

5.  Differences in behavior of tube current modulation techniques for thoracic CT examinations between male and female anthropomorphic phantoms.

Authors:  Kosuke Matsubara; Pei-Jan Paul Lin; Atsushi Fukuda; Kichiro Koshida
Journal:  Radiol Phys Technol       Date:  2014-05-27

6.  CT pulmonary angiography using organ dose modulation with an iterative reconstruction algorithm and 3D Smart mA in different body mass indices: image quality and radiation dose.

Authors:  Yongxia Zhao; Ziwei Zuo; Shujie Cheng; Yanmin Wu
Journal:  Radiol Med       Date:  2018-05-03       Impact factor: 3.469

7.  Imaging Surveillance After Proximal Aortic Operations: Is it Necessary?

Authors:  Alexander Iribarne; Jeffrey Keenan; Ehsan Benrashid; Hanghang Wang; James M Meza; Asvin Ganapathi; Jeffrey G Gaca; Han W Kim; Lynne M Hurwitz; G Chad Hughes
Journal:  Ann Thorac Surg       Date:  2016-09-24       Impact factor: 4.330

Review 8.  Overview of CT technologies for children.

Authors:  Donald P Frush
Journal:  Pediatr Radiol       Date:  2014-10-11

9.  Pros and cons of organ shielding for CT imaging.

Authors:  Ehsan Samei
Journal:  Pediatr Radiol       Date:  2014-10-11

10.  Comparative diagnostic test accuracy of post-esophagectomy water-soluble computed tomography and fluoroscopic swallow studies: A meta-analysis.

Authors:  Timothy E Murray; Martina Morrin
Journal:  Indian J Radiol Imaging       Date:  2018 Jan-Mar
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.