Literature DB >> 22733899

CT angiography of the renal arteries: comparison of lower-tube-voltage CTA with moderate-concentration iodinated contrast material and conventional CTA.

Eun-Suk Cho1, Jeong-Sik Yu, Jhii-Hyun Ahn, Joo Hee Kim, Jae-Joon Chung, Hyeon-Kyeong Lee, Kyung Hee Lee.   

Abstract

OBJECTIVE: The objective of our study was to investigate the feasibility of an 80-kVp protocol using a moderate-concentration contrast medium (CM) for CT angiography of the renal arteries by comparison with a conventional 120-kVp protocol using a high-concentration CM. SUBJECTS AND METHODS: Attenuation values and signal-to-noise ratios (SNRs) were determined in a phantom for the 120-kVp protocol with a high-concentration CM and the 80-kVp protocol with a moderate-concentration CM. In addition, 50 patients were prospectively enrolled in the study: 25 were scanned with 120 kVp and 200 effective mAs (mAs(eff)) after the administration of 110 mL of high-concentration CM (370 mg I/mL), and the other 25 were scanned with 80 kVp and 585 mAs(eff) after the administration of 110 mL of moderate-concentration CM (300 mg I/mL). Images of the two groups were compared in terms of arterial attenuation, SNR, contrast-to-noise ratio (CNR), and subjective degree of arterial enhancement and image quality.
RESULTS: The mean attenuation of the main renal artery was significantly higher (p < 0.001) in the 80-kVp group who received moderate-concentration CM (mean ± SD, 370.0 ± 65.0 HU) than in the 120-kVp group who received high-concentration CM (269.9 ± 27.8 HU) without significant differences in SNR and CNR values. The 80-kVp protocol had significantly higher quality scores for arterial enhancement, sharpness of the artery, and overall diagnostic quality compared with the 120-kVp protocol. The effective dose of the 80-kVp protocol (4.5 mSv) was 8.2% lower than that of the 120-kVp protocol (4.9 mSv).
CONCLUSION: The use of 80 kVp with moderate-concentration CM could improve arterial enhancement and provide superior image quality with a smaller amount of iodine and a lower radiation dose.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22733899     DOI: 10.2214/AJR.11.7450

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  14 in total

Review 1.  Contrast medium administration and image acquisition parameters in renal CT angiography: what radiologists need to know.

Authors:  Charbel Saade; Ibrahim Alsheikh Deeb; Maha Mohamad; Hussain Al-Mohiy; Fadi El-Merhi
Journal:  Diagn Interv Radiol       Date:  2016 Mar-Apr       Impact factor: 2.630

2.  Feasibility of low-concentration iodinated contrast medium with lower-tube-voltage dual-source CT aortography using iterative reconstruction: comparison with automatic exposure control CT aortography.

Authors:  Hee Jeong Shin; Song Soo Kim; Jae-Hwan Lee; Jae-Hyeong Park; Jin-Ok Jeong; Seon Ah Jin; Byung Seok Shin; Kyung-Sook Shin; Moonsang Ahn
Journal:  Int J Cardiovasc Imaging       Date:  2015-11-30       Impact factor: 2.357

3.  The role of CT angiography in the evaluation of pediatric renovascular hypertension.

Authors:  Jessica Kurian; Monica Epelman; Kassa Darge; Kevin Meyers; Els Nijs; Jeffrey C Hellinger
Journal:  Pediatr Radiol       Date:  2012-12-04

4.  Iterative model reconstruction (IMR) algorithm for reduced radiation dose renal artery CT angiography with different tube voltage protocols.

Authors:  Le Qin; ZePeng Ma; FuHua Yan; WenJie Yang
Journal:  Radiol Med       Date:  2017-10-20       Impact factor: 3.469

5.  Perihilar branching patterns of renal artery and extrarenal length of arterial branches and tumour-feeding arteries on multidetector CT angiography.

Authors:  W Y Kang; D J Sung; B J Park; M J Kim; N Y Han; S B Cho; C H Kang; S H Kang
Journal:  Br J Radiol       Date:  2013-03       Impact factor: 3.039

6.  Effects of different tube potentials and iodine concentrations on image enhancement, contrast-to-noise ratio and noise in micro-CT images: a phantom study.

Authors:  Hairil Rashmizal Abdul Razak; Said Mohd Shaffiq Said Rahmat; Wan Mazlina Md Saad
Journal:  Quant Imaging Med Surg       Date:  2013-10

Review 7.  Low radiation dose in computed tomography: the role of iodine.

Authors:  Andrik J Aschoff; Carlo Catalano; Miles A Kirchin; Martin Krix; Thomas Albrecht
Journal:  Br J Radiol       Date:  2017-05-04       Impact factor: 3.039

8.  Split-bolus contrast injection protocol enhances the visualization of the thoracic vasculature and reduced radiation dose during chest CT.

Authors:  Salah Zein-El-Dine; Imad Bou Akl; Maha Mohamad; Ahmad Chmaisse; Stephanie Chahwan; Karl Asmar; Fadi El-Merhi; Charbel Saade
Journal:  Br J Radiol       Date:  2018-10-01       Impact factor: 3.039

9.  Validation of computed tomography angiography as a complementary test in the assessment of renal artery stenosis: a comparison with digital subtraction angiography.

Authors:  Anilawan S Fleury; Rachelle E Durand; Anne Marie Cahill; Xiaowei Zhu; Kevin E Meyers; Hansel J Otero
Journal:  Pediatr Radiol       Date:  2021-08-10

10.  Double-low protocol for hepatic dynamic CT scan: Effect of low tube voltage and low-dose iodine contrast agent on image quality.

Authors:  Xiuli Zhang; Shaodong Li; Wenlou Liu; Ning Huang; Jingjing Li; Li Cheng; Kai Xu
Journal:  Medicine (Baltimore)       Date:  2016-06       Impact factor: 1.889

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.