Literature DB >> 22721892

Intra-operative cone-beam CT (O-arm) and stereotactic navigation in acute spinal trauma surgery.

Rowan Schouten1, Robert Lee, Michael Boyd, Scott Paquette, Marcel Dvorak, Brian K Kwon, Charles Fisher, John Street.   

Abstract

The purpose of this ambispective cohort study is to describe the emerging role of intra-operative cone-beam CT (O-arm®, Medtronic, Minneapolis, MN, USA), frequently coupled with stereotactic navigation (StealthStation®, Medtronic), in the surgical management of acute spinal trauma. All patients with acute spinal trauma between May 2009 and May 2011 who were treated with the use of the O-arm were identified from a prospectively collected spine database and retrospectively analyzed to characterize indications and outcomes. Over the two-year period, the O-arm was used in 183 spinal operations; 27 of these (15%) involved acute spinal trauma. Within the trauma cohort, 14 injuries were in the cervical spine, nine at the cervicothoracic junction, and four were in the thoracolumbar spine. In 12 patients (44%) pre-existing aberrant and challenging anatomy, commonly ankylosing conditions, were present. Surgical techniques included transarticular atlantoaxial fixation and direct osteosynthesis of a Hangman's fracture performed entirely percutaneously (via two stab incisions) using O-arm assisted stereotactic navigation. No trauma cases using O-arm assisted navigation had iatrogenic neurovascular injury and none required subsequent revision surgery for implant malposition, compared with a revision rate of 1.2% of patients with non-navigated acute spinal trauma during the same interval. Technical factors associated with successful application of this technology in the setting of acute spinal trauma were detailed. O-arm assisted navigation can overcome anatomical challenges and broaden the available stabilization options in the management of acute spinal trauma. Other advantages include protecting the surgical team from cumulative fluoroscopic radiation exposure and patients from repeat surgery due to implant malposition.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22721892     DOI: 10.1016/j.jocn.2012.01.020

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  19 in total

1.  Computer-Assisted Orthopedic and Trauma Surgery.

Authors:  Timo Stübig; Henning Windhagen; Christian Krettek; Max Ettinger
Journal:  Dtsch Arztebl Int       Date:  2020-11-20       Impact factor: 5.594

2.  A case series of rapid prototyping and intraoperative imaging in orbital reconstruction.

Authors:  Christopher G T Lim; Duncan I Campbell; Nicholas Cook; Jason Erasmus
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2014-11-03

3.  Known-component 3D image reconstruction for improved intraoperative imaging in spine surgery: A clinical pilot study.

Authors:  Xiaoxuan Zhang; Ali Uneri; J Webster Stayman; Corinna C Zygourakis; Sheng-Fu L Lo; Nicholas Theodore; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2019-06-30       Impact factor: 4.071

4.  Performance evaluation of MIND demons deformable registration of MR and CT images in spinal interventions.

Authors:  S Reaungamornrat; T De Silva; A Uneri; J Goerres; M Jacobson; M Ketcha; S Vogt; G Kleinszig; A J Khanna; J-P Wolinsky; J L Prince; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2016-11-03       Impact factor: 3.609

5.  Does intraoperative navigation improve the accuracy of pedicle screw placement in the apical region of dystrophic scoliosis secondary to neurofibromatosis type I: comparison between O-arm navigation and free-hand technique.

Authors:  Mengran Jin; Zhen Liu; Xingyong Liu; Huang Yan; Xiao Han; Yong Qiu; Zezhang Zhu
Journal:  Eur Spine J       Date:  2015-05-13       Impact factor: 3.134

6.  Burden of disease of reoperations in instrumental spinal surgeries in Germany.

Authors:  Christian Jacob; Elena Annoni; Jennifer Scarlet Haas; Sebastian Braun; Michael Winking; Jörg Franke
Journal:  Eur Spine J       Date:  2015-06-29       Impact factor: 3.134

7.  2D-3D radiograph to cone-beam computed tomography (CBCT) registration for C-arm image-guided robotic surgery.

Authors:  Wen Pei Liu; Yoshito Otake; Mahdi Azizian; Oliver J Wagner; Jonathan M Sorger; Mehran Armand; Russell H Taylor
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-12-12       Impact factor: 2.924

8.  Deformable image registration with local rigidity constraints for cone-beam CT-guided spine surgery.

Authors:  S Reaungamornrat; A S Wang; A Uneri; Y Otake; A J Khanna; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2014-06-17       Impact factor: 3.609

9.  MIND Demons for MR-to-CT Deformable Image Registration In Image-Guided Spine Surgery.

Authors:  S Reaungamornrat; T De Silva; A Uneri; J-P Wolinsky; A J Khanna; G Kleinszig; S Vogt; J L Prince; J H Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-18

10.  MIND Demons: Symmetric Diffeomorphic Deformable Registration of MR and CT for Image-Guided Spine Surgery.

Authors:  Sureerat Reaungamornrat; Tharindu De Silva; Ali Uneri; Sebastian Vogt; Gerhard Kleinszig; Akhil J Khanna; Jean-Paul Wolinsky; Jerry L Prince; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2016-06-02       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.