Literature DB >> 22717504

Signal quality estimation with multichannel adaptive filtering in intensive care settings.

Ikaro Silva1, Joon Lee, Roger G Mark.   

Abstract

A signal quality estimate of a physiological waveform can be an important initial step for automated processing of real-world data. This paper presents a new generic point-by-point signal quality index (SQI) based on adaptive multichannel prediction that does not rely on ad hoc morphological feature extraction from the target waveform. An application of this new SQI to photoplethysmograms (PPG), arterial blood pressure (ABP) measurements, and ECG showed that the SQI is monotonically related to signal-to-noise ratio (simulated by adding white Gaussian noise) and to subjective human quality assessment of 1361 multichannel waveform epochs. A receiver-operating-characteristic (ROC) curve analysis, with the human "bad" quality label as positive and the "good" quality label as negative, yielded areas under the ROC curve of 0.86 (PPG), 0.82 (ABP), and 0.68 (ECG).

Entities:  

Mesh:

Year:  2012        PMID: 22717504      PMCID: PMC3652526          DOI: 10.1109/TBME.2012.2204882

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  15 in total

1.  PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals.

Authors:  A L Goldberger; L A Amaral; L Glass; J M Hausdorff; P C Ivanov; R G Mark; J E Mietus; G B Moody; C K Peng; H E Stanley
Journal:  Circulation       Date:  2000-06-13       Impact factor: 29.690

2.  Threshold modeling of autonomic control of heart rate variability.

Authors:  G B Stanley; K Poolla; R A Siegel
Journal:  IEEE Trans Biomed Eng       Date:  2000-09       Impact factor: 4.538

3.  PhysioNet 2010 Challenge: A Robust Multi-Channel Adaptive Filtering Approach to the Estimation of Physiological Recordings.

Authors:  Ikaro Silva
Journal:  Comput Cardiol (2010)       Date:  2010

4.  Reduction of false arterial blood pressure alarms using signal quality assessment and relationships between the electrocardiogram and arterial blood pressure.

Authors:  W Zong; G B Moody; R G Mark
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

5.  Multiparameter Intelligent Monitoring in Intensive Care II: a public-access intensive care unit database.

Authors:  Mohammed Saeed; Mauricio Villarroel; Andrew T Reisner; Gari Clifford; Li-Wei Lehman; George Moody; Thomas Heldt; Tin H Kyaw; Benjamin Moody; Roger G Mark
Journal:  Crit Care Med       Date:  2011-05       Impact factor: 7.598

6.  Pulse photopletismography amplitude decrease detector for sleep apnea evaluation in children.

Authors:  Eduardo Gil; Violeta Monasterio; Pablo Laguna; Jose Maria Vergara
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2005

7.  Two-stage approach for detection and reduction of motion artifacts in photoplethysmographic data.

Authors:  Rajet Krishnan; Balasubramaniam Bala Natarajan; Steve Warren
Journal:  IEEE Trans Biomed Eng       Date:  2010-02-17       Impact factor: 4.538

8.  Assessing ECG signal quality on a coronary care unit.

Authors:  J Allen; A Murray
Journal:  Physiol Meas       Date:  1996-11       Impact factor: 2.833

9.  Algorithms to qualify respiratory data collected during the transport of trauma patients.

Authors:  Liangyou Chen; Thomas McKenna; Andrew Reisner; Jaques Reifman
Journal:  Physiol Meas       Date:  2006-06-27       Impact factor: 2.833

10.  Artificial arterial blood pressure artifact models and an evaluation of a robust blood pressure and heart rate estimator.

Authors:  Qiao Li; Roger G Mark; Gari D Clifford
Journal:  Biomed Eng Online       Date:  2009-07-08       Impact factor: 2.819

View more
  7 in total

1.  Sensor fusion methods for reducing false alarms in heart rate monitoring.

Authors:  Gabriel Borges; Valner Brusamarello
Journal:  J Clin Monit Comput       Date:  2015-10-06       Impact factor: 2.502

2.  Adaptive motion artefact reduction in respiration and ECG signals for wearable healthcare monitoring systems.

Authors:  Zhengbo Zhang; Ikaro Silva; Dalei Wu; Jiewen Zheng; Hao Wu; Weidong Wang
Journal:  Med Biol Eng Comput       Date:  2014-10-02       Impact factor: 2.602

Review 3.  -Omic and Electronic Health Record Big Data Analytics for Precision Medicine.

Authors:  Po-Yen Wu; Chih-Wen Cheng; Chanchala D Kaddi; Janani Venugopalan; Ryan Hoffman; May D Wang
Journal:  IEEE Trans Biomed Eng       Date:  2016-10-10       Impact factor: 4.538

4.  Novel Signal Noise Reduction Method through Cluster Analysis, Applied to Photoplethysmography.

Authors:  William Waugh; John Allen; James Wightman; Andrew J Sims; Thomas A W Beale
Journal:  Comput Math Methods Med       Date:  2018-01-29       Impact factor: 2.238

5.  A new, short-recorded photoplethysmogram dataset for blood pressure monitoring in China.

Authors:  Yongbo Liang; Zhencheng Chen; Guiyong Liu; Mohamed Elgendi
Journal:  Sci Data       Date:  2018-02-27       Impact factor: 6.444

6.  An optimal filter for short photoplethysmogram signals.

Authors:  Yongbo Liang; Mohamed Elgendi; Zhencheng Chen; Rabab Ward
Journal:  Sci Data       Date:  2018-05-01       Impact factor: 6.444

7.  Detection and classification of ECG noises using decomposition on mixed codebook for quality analysis.

Authors:  Pramendra Kumar; Vijay Kumar Sharma
Journal:  Healthc Technol Lett       Date:  2020-02-18
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.