Literature DB >> 20172800

Two-stage approach for detection and reduction of motion artifacts in photoplethysmographic data.

Rajet Krishnan1, Balasubramaniam Bala Natarajan, Steve Warren.   

Abstract

Corruption of photopleythysmograms (PPGs) by motion artifacts has been a serious obstacle to the reliable use of pulse oximeters for real-time, continuous state-of-health monitoring. In this paper, we propose an automated, two-stage PPG data processing method to minimize the effects of motion artifacts. The technique is based on our prior work related to motion artifact detection (stage 1) [R. Krishnan, B. Natarajan, and S. Warren, "Analysis and detection of motion artifacts in photoplethysmographic data using higher order statistics,'' in Proc. IEEE Int. Conf. Acoust., Speech, Signal Process. (ICASSP 2008), Las Vegas, Nevada, Apr. 2008, pp. 613-616] and motion artifact reduction (stage 2) [R. Krishnan, B. Natarajan, and S. Warren, "Motion artifact reduction in photoplethysmography using magnitude-based frequency domain independent component analysis,'' in Proc. 17th Int. Conf. Comput. Commun. Network, St. Thomas, Virgin Islands, Aug. 2008, pp. 1-5]. Regarding stage 1, we present novel and consistent techniques to detect the presence of motion artifact in PPGs given higher order statistical information present in the data. We analyze these data in the time and frequency domains (FDs) and identify metrics to distinguish between clean and motion-corrupted data. A Neyman-Pearson detection rule is formulated for each of the metrics. Furthermore, by treating each of the metrics as observations from independent sensors, we employ hard fusion and soft fusion techniques presented in [Z. Chair and P. Varshney, "Optimal data fusion in multiple sensor detection systems,'' IEEE Trans. Aerosp. Electron. Syst., AES, vol. 1, no. 1, pp. 98-101, Jan. 1986] and [C. C. Lee and J. J. Chao, "Optimum local decision space partitioning for distributed detection,'' IEEE Trans. Aerosp. Electron. Syst., AES, vol. 25, no. 7, pp. 536-544, Jul. 1989], respectively, in order to fuse individual decisions into a global system decision. For stage two, we propose a motion artifact reduction method that is effective even in the presence of severe subject movement. The approach involves an enhanced preprocessing unit consisting of a motion detection unit (MDU, developed in this paper), period estimation unit, and Fourier series reconstruction unit. The MDU identifies clean data frames versus those corrupted with motion artifacts. The period estimation unit determines the fundamental frequency of a corrupt frame. The Fourier series reconstruction unit reconstructs the final preprocessed signal by utilizing the spectrum variability of the pulse waveform. Preprocessed data are then fed to a magnitude-based FD independent component analysis unit. This helps reduce motion artifacts present at the frequencies of the reconstruction components. Experimental results are presented to demonstrate the efficacy of the overall motion artifact reduction method.

Entities:  

Mesh:

Year:  2010        PMID: 20172800     DOI: 10.1109/TBME.2009.2039568

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  33 in total

1.  Sensor fusion methods for reducing false alarms in heart rate monitoring.

Authors:  Gabriel Borges; Valner Brusamarello
Journal:  J Clin Monit Comput       Date:  2015-10-06       Impact factor: 2.502

Review 2.  A review of signals used in sleep analysis.

Authors:  A Roebuck; V Monasterio; E Gederi; M Osipov; J Behar; A Malhotra; T Penzel; G D Clifford
Journal:  Physiol Meas       Date:  2013-12-17       Impact factor: 2.833

3.  Signal quality estimation with multichannel adaptive filtering in intensive care settings.

Authors:  Ikaro Silva; Joon Lee; Roger G Mark
Journal:  IEEE Trans Biomed Eng       Date:  2012-06-14       Impact factor: 4.538

Review 4.  Detection and Monitoring of Viral Infections via Wearable Devices and Biometric Data.

Authors:  Craig J Goergen; MacKenzie J Tweardy; Steven R Steinhubl; Stephan W Wegerich; Karnika Singh; Rebecca J Mieloszyk; Jessilyn Dunn
Journal:  Annu Rev Biomed Eng       Date:  2021-12-21       Impact factor: 11.324

5.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

6.  Motion and Noise Artifact-Resilient Atrial Fibrillation Detection using a Smartphone.

Authors:  Jo Woon Chong; Chae Ho Cho; Fatemehsadat Tabei; Duy Le-Anh; Nada Esa; David D McManus; Ki H Chon
Journal:  IEEE J Emerg Sel Top Circuits Syst       Date:  2018-03-22       Impact factor: 3.916

7.  Quantifying Movement in Preterm Infants Using Photoplethysmography.

Authors:  Ian Zuzarte; Premananda Indic; Dagmar Sternad; David Paydarfar
Journal:  Ann Biomed Eng       Date:  2018-09-25       Impact factor: 3.934

8.  A Comparative Study of Physiological Monitoring with a Wearable Opto-Electronic Patch Sensor (OEPS) for Motion Reduction.

Authors:  Abdullah Alzahrani; Sijung Hu; Vicente Azorin-Peris
Journal:  Biosensors (Basel)       Date:  2015-06-08

9.  A multi-channel opto-electronic sensor to accurately monitor heart rate against motion artefact during exercise.

Authors:  Abdullah Alzahrani; Sijung Hu; Vicente Azorin-Peris; Laura Barrett; Dale Esliger; Matthew Hayes; Shafique Akbare; Jérôme Achart; Sylvain Kuoch
Journal:  Sensors (Basel)       Date:  2015-10-12       Impact factor: 3.576

10.  iPhone 4s photoplethysmography: which light color yields the most accurate heart rate and normalized pulse volume using the iPhysioMeter Application in the presence of motion artifact?

Authors:  Kenta Matsumura; Peter Rolfe; Jihyoung Lee; Takehiro Yamakoshi
Journal:  PLoS One       Date:  2014-03-11       Impact factor: 3.240

View more