Literature DB >> 2271364

Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball.

I Kempf1, M Semlitsch.   

Abstract

The purpose of this case study of severe metallosis is to draw the attention of orthopedic surgeons to extremely serious results of this kind in the event of the fracture of the ceramic ball in a total hip prosthesis. Eleven months after implantation of a KJF hip prosthesis with an aluminum oxide ceramic ball in combination with a polyethylene acetabular cup, fracture of the ceramic ball was observed. After examining the polyethylene cup during the revision operation, the operating orthopedic surgeon merely replaced the fractured ceramic ball with a metal ball head made of stainless steel. Twenty-five months after this procedure, radiography revealed massive wear of the steel ball head with resulting severe metallosis of the surrounding tissues. All prosthetic components therefore had to be removed. Careful examination of the removed prosthetic components clearly showed that sharp-edged ceramic particles originating from the fractured ceramic ball had become embedded in the bearing surface of the polyethylene cup. These tiny ceramic fragments, ranging from 0.05 to 2 mm, were too small to be seen by the operating surgeon's unaided eye. It is these extremely hard ceramic fragments that were responsible for the massive wear of the steel ball head, the hardness of which is approximately ten times less than that of aluminum oxide ceramic. The fracture of the ceramic ball further resulted in damage to the metal taper of the stemmed femoral component. In cases of this kind it is consequently absolutely essential to remove both the polyethylene cup and the ball head, and--if necessary--the femoral component as well.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2271364     DOI: 10.1007/bf00419946

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  2 in total

1.  Total hip replacement: rotating versus fixed and metal versus ceramic heads.

Authors:  B G Weber
Journal:  Hip       Date:  1981

2.  [The adsorption behaviour of high purity alumina ceramics exposed to fluids (author's transl)].

Authors:  W Dawihl; E Dörre
Journal:  Biomed Tech (Berl)       Date:  1980-12       Impact factor: 1.411

  2 in total
  15 in total

1.  Implant materials for hip endoprostheses: old proofs and new trends.

Authors:  M Semlitsch; H G Willert
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

2.  Metallosis caused by alumina ceramic screw fixation of grafted bone in a bipolar hip endoprosthesis.

Authors:  M Watanabe; H Okumura; Y Kihara; T Shibata
Journal:  Arch Orthop Trauma Surg       Date:  1993       Impact factor: 3.067

Review 3.  Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty.

Authors:  Didier Hannouche; Amine Zaoui; Frédéric Zadegan; Laurent Sedel; Rémy Nizard
Journal:  Int Orthop       Date:  2010-12-30       Impact factor: 3.075

4.  Reduced wear of cross-linked UHMWPE using magnesia-stabilized zirconia femoral heads in a hip simulator.

Authors:  Marcel E Roy; Leo A Whiteside; Mark E Magill; Brian J Katerberg
Journal:  Clin Orthop Relat Res       Date:  2011-02-11       Impact factor: 4.176

5.  Ceramic liner fracture and impingement in total hip arthroplasty.

Authors:  Amy Steinhoff; Victor Hakim; Richard H Walker; Clifford W Colwell; Steven N Copp
Journal:  HSS J       Date:  2014-10-21

6.  Is there a risk in placing a ceramic head on a previously implanted trunion?

Authors:  Didier Hannouche; Jérôme Delambre; Frédéric Zadegan; Laurent Sedel; Rémy Nizard
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

Review 7.  Strategies for head and inlay exchange in revision hip arthroplasty.

Authors:  Martin Pospischill; Karl Knahr
Journal:  Int Orthop       Date:  2010-11-19       Impact factor: 3.075

Review 8.  [Fracture of the ceramic head in total hip prosthesis. Apropos of 2 cases].

Authors:  P Mangione; X Pascarel; B Vinciguerra; J L Honton
Journal:  Int Orthop       Date:  1994       Impact factor: 3.075

Review 9.  [The problem of fractures of ceramic heads. What should be done?].

Authors:  H R Dürr
Journal:  Orthopade       Date:  2009-08       Impact factor: 1.087

10.  Long-term durability of alumina ceramic heads in THA.

Authors:  Nicholas A Beckmann; Tobias Gotterbarm; Moritz M Innmann; Christian Merle; Thomas Bruckner; J Philippe Kretzer; Marcus R Streit
Journal:  BMC Musculoskelet Disord       Date:  2015-09-12       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.