Literature DB >> 22710970

Influence of peritoneal dialysis solution on measurements of fluid status by bioimpedance spectroscopy.

Simon Paul Parmentier1, Holger Schirutschke, Bertram Schmitt, Jens Schewe, Kay Herbrig, Frank Pistrosch, Jens Passauer.   

Abstract

PURPOSE AND METHODS: The accurate estimation of volume status is a central problem in dialysis patients. Recently, a bioimpedance spectroscopy (BIS) device (BCM Body Composition Monitor FMC, Germany) has attained growing interest in this regard. By processing the raw data for extracellular water (ECW) and intracellular water (ICW) by means of a validated body composition model, this device allows a quantification of the individual fluid overload (FO) compared to a representative healthy population. In this study, we addressed the issue whether the presence of peritoneal dialysate has an impact on measurements of FO by BIS in PD patients.
RESULTS: Forty-two BIS measurements using the BCM device were performed both in the absence (D-) and presence (D+) of peritoneal dialysate in 17 stable PD patients. Data for ECW, ICW and FO (D+; D-) were analyzed by paired t test and linear regression. Mean FO was 0.99 ± 1.17 L in D- and 0.94 ± 1.27 in D+ (p = n.s. paired t test). Linear regression demonstrated an excellent degree of conformity between FO (D-) and FO (D+) (r (2) = 0.93).
CONCLUSION: The presence of peritoneal fluid in PD patients has a negligible influence on measurements of FO by BIS. The BIS measurements can be therefore conveniently and reliably done without emptying the peritoneal cavity; this may facilitate the use of BIS in this particular group of patients.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22710970     DOI: 10.1007/s11255-012-0216-y

Source DB:  PubMed          Journal:  Int Urol Nephrol        ISSN: 0301-1623            Impact factor:   2.370


  11 in total

1.  Effect of fluid and sodium removal on mortality in peritoneal dialysis patients.

Authors:  K Ateş; G Nergizoğlu; K Keven; A Sen; S Kutlay; S Ertürk; N Duman; O Karatan; A E Ertuğ
Journal:  Kidney Int       Date:  2001-08       Impact factor: 10.612

2.  Body fluid volume determination via body composition spectroscopy in health and disease.

Authors:  Ulrich M Moissl; Peter Wabel; Paul W Chamney; Ingvar Bosaeus; Nathan W Levin; Anja Bosy-Westphal; Oliver Korth; Manfred J Müller; Lars Ellegård; Vibeke Malmros; Charoen Kaitwatcharachai; Martin K Kuhlmann; Fansan Zhu; Nigel J Fuller
Journal:  Physiol Meas       Date:  2006-07-25       Impact factor: 2.833

3.  A whole-body model to distinguish excess fluid from the hydration of major body tissues.

Authors:  Paul W Chamney; Peter Wabel; Ulrich M Moissl; Manfred J Müller; Anja Bosy-Westphal; Oliver Korth; Nigel J Fuller
Journal:  Am J Clin Nutr       Date:  2007-01       Impact factor: 7.045

4.  Importance of whole-body bioimpedance spectroscopy for the management of fluid balance.

Authors:  Peter Wabel; Paul Chamney; Ulrich Moissl; Tomas Jirka
Journal:  Blood Purif       Date:  2009-01-23       Impact factor: 2.614

5.  Body composition monitor measurement technique for the detection of volume status in peritoneal dialysis patients: the effect of abdominal fullness.

Authors:  Savas Sipahi; Ender Hur; Saadet Demirtas; Ibrahim Kocayigit; Devrim Bozkurt; Ali Tamer; Huseyin Gunduz; Soner Duman
Journal:  Int Urol Nephrol       Date:  2011-05-04       Impact factor: 2.370

6.  Volume status in peritoneal dialysis.

Authors:  Graham Woodrow
Journal:  Perit Dial Int       Date:  2011-03       Impact factor: 1.756

7.  Volume control in peritoneal dialysis patients guided by bioimpedance spectroscopy assessment.

Authors:  Ya-Jun Luo; Xin-Hong Lu; Feidhlim Woods; Tao Wang
Journal:  Blood Purif       Date:  2011-01-14       Impact factor: 2.614

8.  Application of body composition monitoring to peritoneal dialysis patients.

Authors:  Carlo Crepaldi; Sachin Soni; Chang Yin Chionh; Peter Wabel; Dinna N Cruz; Claudio Ronco
Journal:  Contrib Nephrol       Date:  2009-06-03       Impact factor: 1.580

9.  Comparison of volume overload with cycler-assisted versus continuous ambulatory peritoneal dialysis.

Authors:  Sara N Davison; Gian S Jhangri; Kailash Jindal; Neesh Pannu
Journal:  Clin J Am Soc Nephrol       Date:  2009-04-30       Impact factor: 8.237

10.  Evaluation of clinical dry weight assessment in haemodialysis patients using bioimpedance spectroscopy: a cross-sectional study.

Authors:  Jens Passauer; Helga Petrov; Andreas Schleser; Joachim Leicht; Klaus Pucalka
Journal:  Nephrol Dial Transplant       Date:  2009-10-06       Impact factor: 5.992

View more
  6 in total

1.  Evaluation of body composition and fluid volume using a body composition monitor: does intraperitoneal fluid matter?

Authors:  Rafaela Siviero Caron-Lienert; Ana E Figueiredo; Bartira Pinheiro da Costa; Cristina F Bombardelli; Alessandra C Pizzato; Alessandra Conti; Carlos E Poli-de-Figueiredo
Journal:  Perit Dial Int       Date:  2014-06       Impact factor: 1.756

2.  Intraperitoneal fluid overestimates hydration status assessment by bioimpedance spectroscopy.

Authors:  David Arroyo; Nayara Panizo; Soraya Abad; Almudena Vega; Abraham Rincón; Ana Pérez de José; Juan M López-Gómez
Journal:  Perit Dial Int       Date:  2014-03-01       Impact factor: 1.756

3.  Insulin Resistance in Nondiabetic Peritoneal Dialysis Patients: Associations with Body Composition, Peritoneal Transport, and Peritoneal Glucose Absorption.

Authors:  Ana Paula Bernardo; Jose C Oliveira; Olivia Santos; Maria J Carvalho; Antonio Cabrita; Anabela Rodrigues
Journal:  Clin J Am Soc Nephrol       Date:  2015-10-27       Impact factor: 8.237

4.  Bioimpedance spectroscopy for fluid status assessment in patients with decompensated liver cirrhosis: Implications for peritoneal dialysis.

Authors:  Elisabeth Schwaiger; Amrei Simon; Peter Wabel; Benjamin Schairer; Carolin Berner; Lorenzo Signorini; Matthäus Ernstbrunner; Rayko Evstatiev; Philipp Schwabl; Georg Hinterholzer; Florian Frommlet; Andreas Vychytil; Christian J Müller; Manfred Hecking
Journal:  Sci Rep       Date:  2020-02-18       Impact factor: 4.379

5.  Baseline hydration status in incident peritoneal dialysis patients: the initiative of patient outcomes in dialysis (IPOD-PD study)†.

Authors:  Claudio Ronco; Christian Verger; Carlo Crepaldi; Jenny Pham; Tatiana De Los Ríos; Adelheid Gauly; Peter Wabel; Wim Van Biesen
Journal:  Nephrol Dial Transplant       Date:  2015-03-11       Impact factor: 5.992

6.  Asymptomatic fluid overload predicts survival and cardiovascular event in incident Chinese peritoneal dialysis patients.

Authors:  Jack Kit-Chung Ng; Bonnie Ching-Ha Kwan; Kai-Ming Chow; Wing-Fai Pang; Phyllis Mei-Shan Cheng; Chi-Bon Leung; Philip Kam-To Li; Cheuk-Chun Szeto
Journal:  PLoS One       Date:  2018-08-13       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.