Literature DB >> 22707174

Influence of pH on the tribocorrosion behavior of CpTi in the oral environment: synergistic interactions of wear and corrosion.

Mathew T Mathew1, Savithri Abbey, Nadim J Hallab, Deborah J Hall, Cortino Sukotjo, Markus A Wimmer.   

Abstract

UNLABELLED: Dental implants made of titanium alloys have been used as a predictable therapy approach to replace missing teeth. The oral environment subjects titanium implants to varying conditions like changes in pH, temperature, and saliva contamination leading to chemical corrosion together with mastication process.
OBJECTIVE: In this study, the combined effect of chemical corrosion and wear (so-called tribocorrosion) in the degradation of dental implant material (CpTi) under varying pH oral environment was investigated.
METHODS: Titanium (CpTi) discs were subjected to sliding tests in artificial saliva at varying pHs: 3.0, 6.0, and 9.0. A custom made tribocorrosion apparatus was used to perform the tests. The tribological system consisted of a ceramic ball of 28 mm diameter articulating against the flat face (titanium).
RESULTS: Electrochemical impedance spectroscopy results indicated an increase in electrochemical double layer capacitance (C(dl)) at pH 3.0 and 6.0 after sliding. Surprisingly, in the presence of tribological stresses, the measured current evolution was highest and fluctuated the most at pH 6.0. In addition, the greatest weight loss was measured at pH 6.0.
CONCLUSIONS: Despite reports of CpTi being electrochemically stable down to pH 2.0, this study suggests degradation peaks at near neutral pH values in the presence of motion. At pH 6.0, the passive film layer, typically protecting the surface of titanium may not be reformed cohesively, resulting in more tribocorrosion products at the surface, which are easily sheared off. These findings elevate concern with regard to dental implants because the average pH of the oral cavity is 6.3.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22707174     DOI: 10.1002/jbm.b.32735

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  13 in total

1.  Long-term durability of orthodontic mini-implants.

Authors:  Mona Aly Abbassy; Ahmed Samir Bakry; Khalid Hashim Zawawi; Ali Habib Hassan
Journal:  Odontology       Date:  2017-08-24       Impact factor: 2.634

Review 2.  The biological response to orthopaedic implants for joint replacement: Part I: Metals.

Authors:  Emmanuel Gibon; Derek F Amanatullah; Florence Loi; Jukka Pajarinen; Akira Nabeshima; Zhenyu Yao; Moussa Hamadouche; Stuart B Goodman
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2016-06-21       Impact factor: 3.368

3.  Biomimetic coatings enhance tribocorrosion behavior and cell responses of commercially pure titanium surfaces.

Authors:  Isabella da Silva Vieira Marques; Maria Fernanda Alfaro; Miki Taketomi Saito; Nilson Cristino da Cruz; Christos Takoudis; Richard Landers; Marcelo Ferraz Mesquita; Francisco Humberto Nociti Junior; Mathew T Mathew; Cortino Sukotjo; Valentim Adelino Ricardo Barão
Journal:  Biointerphases       Date:  2016-09-11       Impact factor: 2.456

4.  Dicationic Imidazolium-Based Ionic Liquid Coatings on Zirconia Surfaces: Physico-Chemical and Biological Characterization.

Authors:  Pavan P K Sandhu; Izabelle M Gindri; Danyal A Siddiqui; Danieli C Rodrigues
Journal:  J Funct Biomater       Date:  2017-12-13

5.  Fretting Corrosion Behavior of Experimental Ti-20Cr Compared to Titanium.

Authors:  Tomofumi Sawada; Christine Schille; Atif Almadani; Jürgen Geis-Gerstorfer
Journal:  Materials (Basel)       Date:  2017-02-17       Impact factor: 3.623

6.  Titanium Corrosion Mechanisms in the Oral Environment: A Retrieval Study.

Authors:  Danieli C Rodrigues; Pilar Valderrama; Thomas G Wilson; Kelli Palmer; Anie Thomas; Sathyanarayanan Sridhar; Arvind Adapalli; Maria Burbano; Chandur Wadhwani
Journal:  Materials (Basel)       Date:  2013-11-15       Impact factor: 3.623

7.  Potential Causes of Titanium Particle and Ion Release in Implant Dentistry: A Systematic Review.

Authors:  Rafael Delgado-Ruiz; Georgios Romanos
Journal:  Int J Mol Sci       Date:  2018-11-13       Impact factor: 5.923

8.  Release of titanium after insertion of dental implants with different surface characteristics - an ex vivo animal study.

Authors:  Mattias Pettersson; Jean Pettersson; Margareta Molin Thorén; Anders Johansson
Journal:  Acta Biomater Odontol Scand       Date:  2017-11-14

9.  Biofunctional Sr- and Si-loaded titania nanotube coating of Ti surfaces by anodization-hydrothermal process.

Authors:  Yong Huang; Xue Shen; Haixia Qiao; Hao Yang; Xuejiao Zhang; Yiyao Liu; Hejie Yang
Journal:  Int J Nanomedicine       Date:  2018-01-31

10.  Electrochemical assessment of laser-treated titanium alloy used for dental applications at acidic pH condition (in vitro study).

Authors:  Dalia Ahmed Abd El Daym; Mostafa Esam Gheith; Nadia Ahmed Abbas; Laila Ahmed Rashed; Zeinab A Abd El Aziz
Journal:  Dent Res J (Isfahan)       Date:  2019-09-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.