Hadi Ravan1, Razieh Yazdanparast.
Abstract
Loop-mediated isothermal amplification in conjunction with enzyme-linked immunosorbent assay (LAMP-ELISA) provides a sensitive, specific and cost-effective method for detection of etiological causes of infections. The present study developed a reliable LAMP-ELISA diagnostic kit for identification of Salmonella serogroup D strains and evaluated its potential use in the detection of Salmonella serovars Enteritidis and Typhi. The LAMP-ELISA assay used a serogroup D/A-specific primer set to amplify a region of the prt gene, followed by hybridization of the digoxigenin-labeled products to a highly specific oligonucleotide probe for exact identification of serogroup D serovars. Among the bacteria tested, a positive reaction was only observed for strains belong to Salmonella serogroup D. The detection limit of the LAMP-ELISA assay was 4 CFU per tube, which was lower than PCR-ELISA assay with the same target gene (50 CFU per tube). Finally, the technique was successfully applied to an artificially contaminated meat sample with a detection limit 10(3) CFU mL(-1), which was 10 times more sensitive than PCR-ELISA. Overall, the LAMP-ELISA assay could be used as a sensitive alternative method to PCR-ELISA for the specific detection of Salmonella serogroup D serovars in routine food microbiology or clinical laboratories worldwide.Entities:
Mesh:
Substances:
Year: 2012 PMID: 22704377 DOI: 10.1016/j.aca.2012.04.034
Source DB: PubMed Journal: Anal Chim Acta ISSN: 0003-2670 Impact factor: 6.558