INTRODUCTION: The determination of root canal length is a significant outcome predictor for endodontic treatments. The aim of this prospective, controlled clinical study was to analyze endodontic working length measurements in preexisting cone-beam computed tomography (CBCT) scans and to compare them with clinical root canal length determination by using an electronic apex locator (EAL).
METHODS: All included patients had received a CBCT scan independent of the present study and needed root canal treatment of at least 1 anterior tooth visible in the field of view. Clinically, the root canal length was measured with an EAL by an endodontist. This measurement was compared with the root canal length as measured on vestibulo-oral and mesiodistal CBCT sections by an examiner not involved in the endodontic treatment. The CBCT measurements were repeated once for analysis of intrarater reliability.
RESULTS: Forty anterior teeth in 30 patients (13 women and 17 men; average age, 44 years; range, 18-80 years) were included in this investigation. The Pearson correlation coefficient (r) comparing the root canal length measurements by using CBCT and EAL was 0.97. In addition, high intrarater reliability for the CBCT measurements was found (r = 0.99).
CONCLUSIONS: This prospective, controlled clinical study showed that limited CBCT scans can be used for endodontic working length measurements. Future studies are needed to evaluate whether preexisting CBCT scans could replace initial periapical radiographs and working length periapical radiographs.
Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22703648     DOI: 10.1016/j.joen.2012.03.024

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  12 in total

1.  The use of cone beam computed tomography to predetermine root canal lengths in molar teeth: a comparison between two-dimensional and three-dimensional measurements.

Authors:  J P Tchorz; P J Poxleitner; S Stampf; S B M Patzelt; D Rottke; E Hellwig; M J Altenburger
Journal:  Clin Oral Investig       Date:  2013-07-30       Impact factor: 3.573

2.  Comparing cone-beam computed tomography with periapical radiography for assessing root canal obturation in vivo using microsurgical findings as validation.

Authors:  Dongzhe Song; Lan Zhang; Wei Zhou; Qinghua Zheng; Xingyu Duan; Xuedong Zhou; Dingming Huang
Journal:  Dentomaxillofac Radiol       Date:  2017-03-23       Impact factor: 2.419

3.  Endodontic working length measurements of premolars and molars in high-resolution dental MRI: a clinical pilot study for assessment of reliability and accuracy.

Authors:  Mousa Zidan; Franz S Schwindling; Alexander Juerchott; Johannes Mente; Holger Gehrig; Mathias Nittka; Zahra Hosseini; Johann M E Jende; Sabine Heiland; Martin Bendszus; Tim Hilgenfeld
Journal:  Clin Oral Investig       Date:  2022-07-21       Impact factor: 3.606

Review 4.  Use of preoperative cone-beam computed tomography to aid in establishment of endodontic working length: A systematic review and meta-analysis.

Authors:  Andrew Paterson; Vittorio Franco; Shanon Patel; Federico Foschi
Journal:  Imaging Sci Dent       Date:  2020-09-16

5.  Working Length Determination Using Cone-Beam Computed Tomography, Periapical Radiography and Electronic Apex Locator in Teeth with Apical Periodontitis: A Clinical Study.

Authors:  André Luiz Gomide de Morais; Ana Helena Gonçalves de Alencar; Cyntia Rodrigues de Araújo Estrela; Daniel Almeida Decurcio; Carlos Estrela
Journal:  Iran Endod J       Date:  2016-05-01

6.  Successful orthograde treatment of dens invaginatus Type 3 with a main C-shaped canal based on cone-beam computed tomography evaluation.

Authors:  Michael Solomonov; Joe Ben Itzhak; Avi Levin; Vered Katzenell; Avi Shemesh
Journal:  J Conserv Dent       Date:  2016 Nov-Dec

7.  Accuracy of Software-Based Three-Dimensional Root Canal Length Measurements Using Cone-Beam Computed Tomography.

Authors:  J P Tchorz; K T Wrbas; C Von See; K Vach; Sbm Patzelt
Journal:  Eur Endod J       Date:  2018-11-13

8.  Root canal length measurement of molar teeth using conebeam computed tomography (CBCT): comparison of two dimensional versus three-dimensional methods.

Authors:  Selen Nihal Sisli; Orhan Gulen
Journal:  Eur Oral Res       Date:  2021-05-04

9.  Comparative evaluation of three methods to measure working length - Manual tactile sensation, digital radiograph, and multidetector computed tomography: An in vitro study.

Authors:  Kaushik Dutta; Priti D Desai; Utapal Kumar Das; Soumayabrata Sarkar
Journal:  J Conserv Dent       Date:  2017 Mar-Apr

10.  Correlation of objective image quality and working length measurements in different CBCT machines: An ex vivo study.

Authors:  T G Wolf; F Fischer; R K W Schulze
Journal:  Sci Rep       Date:  2020-11-10       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.