| Literature DB >> 20833511 |
W Pirker1, D Wiedemann, A Lidauer, A A Kocher.
Abstract
This report demonstrates the clinical use of a modified, truly anatomic, root-analogue zirconia implant for immediate replacement of a two-rooted, left first mandibular molar. A 50-year-old female patient with chronic apical periodontitis of the left mandibulary first molar was referred and the tooth was extracted. The mesial root had to be removed surgically due to a root fracture. A truly anatomical, root identical, roughened zirconia implant modified by macro-retentions was manufactured and placed into the extraction socket by tapping 7 days later. After 4 months a composite crown was cemented in place. No complications occurred during the healing period. A good functional and aesthetic result was achieved with minimal bone resorption and soft tissue recession at 30 months follow-up. This report describes the successful clinical use of an immediate, single stage, truly anatomical root-analogue zirconia implant for replacement of a two-rooted tooth. Significant modifications such as macro-retentions yielded primary stability and excellent osseointegration. This novel approach is minimally invasive, respects the underlying anatomy, aids socket prevention, is time- and cost-saving with good patient acceptance as there is no need for bone drilling, sinus lift, bone augmentation or other traumatic procedures.Entities:
Mesh:
Substances:
Year: 2010 PMID: 20833511 DOI: 10.1016/j.ijom.2010.08.003
Source DB: PubMed Journal: Int J Oral Maxillofac Surg ISSN: 0901-5027 Impact factor: 2.789