Literature DB >> 22698644

Correlation of wear in vivo and six laboratory wear methods.

S D Heintze1, M Faouzi, V Rousson, M Ozcan.   

Abstract

OBJECTIVE: We examined the correlation between clinical wear rates of restorative materials and enamel (TRAC Research Foundation, Provo, USA) and the results of six laboratory test methods (ACTA, Alabama (generalized, localized), Ivoclar (vertical, volumetric), Munich, OHSU (abrasion, attrition), Zurich).
METHODS: Individual clinical wear data were available from clinical trials that were conducted by TRAC Research Foundation (formerly CRA) together with general practitioners. For each of the n=28 materials (21 composite resins for intra-coronal restorations [20 direct and 1 indirect], 5 resin materials for crowns, 1 amalgam, enamel) a minimum of 30 restorations had been placed in posterior teeth, mainly molars. The recall intervals were up to 5 years with the majority of materials (n=27) being monitored, however, only for up to 2 years. For the laboratory data, the databases MEDLINE and IADR abstracts were searched for wear data on materials which were also clinically tested by TRAC Research Foundation. Only those data for which the same test parameters (e.g. number of cycles, loading force, type of antagonist) had been published were included in the study. A different quantity of data was available for each laboratory method: Ivoclar (n=22), Zurich (n=20), Alabama (n=17), OHSU and ACTA (n=12), Munich (n=7). The clinical results were summed up in an index and a linear mixed model was fitted to the log wear measurements including the following factors: material, time (0.5, 1, 2 and 3 years), tooth (premolar/molar) and gender (male/female) as fixed effects, and patient as random effect. Relative ranks were created for each material and method; the same was performed with the clinical results.
RESULTS: The mean age of the subjects was 40 (±12) years. The materials had been mostly applied in molars (81%) and 95% of the intracoronal restorations were Class II restorations. The mean number of individual wear data per material was 25 (range 14-42). The mean coefficient of variation of clinical wear data was 53%. The only significant correlation was reached by OHSU (abrasion) with a Spearman r of 0.86 (p=0.001). Zurich, ACTA, Alabama generalized wear and Ivoclar (volume) had correlation coefficients between 0.3 and 0.4. For Zurich, Alabama generalized wear and Munich, the correlation coefficient improved if only composites for direct use were taken into consideration. The combination of different laboratory methods did not significantly improve the correlation. SIGNIFICANCE: The clinical wear of composite resins is mainly dependent on differences between patients and less on the differences between materials. Laboratory methods to test conventional resins for wear are therefore less important, especially since most of them do not reflect the clinical wear.
Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22698644     DOI: 10.1016/j.dental.2012.04.006

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  16 in total

1.  [Evaluation of wear property of Giomer and universal composite in vivo].

Authors:  H L Mu; F C Tian; X Y Wang; X J Gao
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-12-21

2.  Sliding contact wear and subsurface damage of CAD/CAM materials against zirconia.

Authors:  M Wendler; M R Kaizer; R Belli; U Lohbauer; Y Zhang
Journal:  Dent Mater       Date:  2020-01-30       Impact factor: 5.304

3.  Antagonist wear of monolithic zirconia crowns after 2 years.

Authors:  Ulrich Lohbauer; Sven Reich
Journal:  Clin Oral Investig       Date:  2016-06-09       Impact factor: 3.573

4.  Inverse correlations between wear and mechanical properties in biphasic dental materials with ceramic constituents.

Authors:  Oscar Borrero-Lopez; Fernando Guiberteau; Yu Zhang; Brian R Lawn
Journal:  J Mech Behav Biomed Mater       Date:  2020-03-12

5.  The progressive wear and abrasiveness of novel graded glass/zirconia materials relative to their dental ceramic counterparts.

Authors:  Marina R Kaizer; Rafael R Moraes; Sergio S Cava; Yu Zhang
Journal:  Dent Mater       Date:  2019-03-01       Impact factor: 5.304

6.  Two Body Wear of Newly Introduced Nanocomposite Teeth and Cross Linked Four Layered Acrylic Teeth: a Comparitive In Vitro Study.

Authors:  R Ilangkumaran; J Srinivasan; K Baburajan; N Balaji
Journal:  J Indian Prosthodont Soc       Date:  2014-07-17

7.  Eight-year clinical evaluation of two types of resin composite in non-carious cervical lesions.

Authors:  Kei Kaida; Shisei Kubo; Takafumi Egoshi; Yohsuke Taira
Journal:  Clin Oral Investig       Date:  2022-06-25       Impact factor: 3.606

8.  Wear of ceramic-based dental materials.

Authors:  Oscar Borrero-Lopez; Fernando Guiberteau; Yu Zhang; Brian R Lawn
Journal:  J Mech Behav Biomed Mater       Date:  2019-01-12

9.  Damage sensitivity of dental zirconias to simulated occlusal contact.

Authors:  Marcia Borba; Tomoyuki K Okamoto; Michelle Zou; Marina R Kaizer; Yu Zhang
Journal:  Dent Mater       Date:  2020-11-21       Impact factor: 5.304

10.  In-vivo-wear in composite and ceramic full mouth rehabilitations over 3 years.

Authors:  Gintare Burian; Kurt Erdelt; Josef Schweiger; Christine Keul; Daniel Edelhoff; Jan-Frederik Güth
Journal:  Sci Rep       Date:  2021-07-07       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.