Clinically relevant hypoglycemia prediction metrics for event mitigation.

Rebecca A Harvey1, Eyal Dassau, Howard C Zisser, Wendy Bevier, Dale E Seborg, Lois Jovanovič, Francis J Doyle.   

Abstract

BACKGROUND: The purpose of this study was to develop a method to compare hypoglycemia prediction algorithms and choose parameter settings for different applications, such as triggering insulin pump suspension or alerting for rescue carbohydrate treatment.
MATERIALS AND METHODS: Hypoglycemia prediction algorithms with different parameter settings were implemented on an ambulatory dataset containing 490 days from 30 subjects with type 1 diabetes mellitus using the Dexcom™ (San Diego, CA) SEVEN™ continuous glucose monitoring system. The performance was evaluated using a proposed set of metrics representing the true-positive ratio, false-positive rate, and distribution of warning times. A prospective, in silico study was performed to show the effect of using different parameter settings to prevent or rescue from hypoglycemia.
RESULTS: The retrospective study results suggest the parameter settings for different methods of hypoglycemia mitigation. When rescue carbohydrates are used, a high true-positive ratio, a minimal false-positive rate, and alarms with short warning time are desired. These objectives were met with a 30-min prediction horizon and two successive flags required to alarm: 78% of events were detected with 3.0 false alarms/day and 66% probability of alarms occurring within 30 min of the event. This parameter setting selection was confirmed in silico: treating with rescue carbohydrates reduced the duration of hypoglycemia from 14.9% to 0.5%. However, for a different method, such as pump suspension, this parameter setting only reduced hypoglycemia to 8.7%, as can be expected by the low probability of alarming more than 30 min ahead.
CONCLUSIONS: The proposed metrics allow direct comparison of hypoglycemia prediction algorithms and selection of parameter settings for different types of hypoglycemia mitigation, as shown in the prospective in silico study in which hypoglycemia was alerted or treated with rescue carbohydrates.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22690875      PMCID: PMC3409456          DOI: 10.1089/dia.2011.0198

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  16 in total

1.  Diagnostic tests. 1: Sensitivity and specificity.

Authors:  D G Altman; J M Bland
Journal:  BMJ       Date:  1994-06-11

2.  Hypoglycemia prediction and detection using optimal estimation.

Authors:  Cesar C Palerm; John P Willis; James Desemone; B Wayne Bequette
Journal:  Diabetes Technol Ther       Date:  2005-02       Impact factor: 6.118

Review 3.  Defining and reporting hypoglycemia in diabetes: a report from the American Diabetes Association Workgroup on Hypoglycemia.

Authors: 
Journal:  Diabetes Care       Date:  2005-05       Impact factor: 19.112

Review 4.  Practical considerations in the use of real-time continuous glucose monitoring alerts.

Authors:  John Mastrototaro; John B Welsh; Scott Lee
Journal:  J Diabetes Sci Technol       Date:  2010-05-01

5.  Detection of hypoglycemia with continuous interstitial and traditional blood glucose monitoring using the FreeStyle Navigator Continuous Glucose Monitoring System.

Authors:  Geoffrey McGarraugh; Richard Bergenstal
Journal:  Diabetes Technol Ther       Date:  2009-03       Impact factor: 6.118

6.  Real-Time hypoglycemia prediction suite using continuous glucose monitoring: a safety net for the artificial pancreas.

Authors:  Eyal Dassau; Fraser Cameron; Hyunjin Lee; B Wayne Bequette; Howard Zisser; Lois Jovanovic; H Peter Chase; Darrell M Wilson; Bruce A Buckingham; Francis J Doyle
Journal:  Diabetes Care       Date:  2010-06       Impact factor: 17.152

7.  Prevention of nocturnal hypoglycemia using predictive alarm algorithms and insulin pump suspension.

Authors:  Bruce Buckingham; H Peter Chase; Eyal Dassau; Erin Cobry; Paula Clinton; Victoria Gage; Kimberly Caswell; John Wilkinson; Fraser Cameron; Hyunjin Lee; B Wayne Bequette; Francis J Doyle
Journal:  Diabetes Care       Date:  2010-03-03       Impact factor: 19.112

8.  Statistical hypoglycemia prediction.

Authors:  Fraser Cameron; Günter Niemeyer; Karen Gundy-Burlet; Bruce Buckingham
Journal:  J Diabetes Sci Technol       Date:  2008-07

9.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus.

Authors:  D M Nathan; S Genuth; J Lachin; P Cleary; O Crofford; M Davis; L Rand; C Siebert
Journal:  N Engl J Med       Date:  1993-09-30       Impact factor: 91.245

10.  Hypoglycemia prediction with subject-specific recursive time-series models.

Authors:  Meriyan Eren-Oruklu; Ali Cinar; Lauretta Quinn
Journal:  J Diabetes Sci Technol       Date:  2010-01-01
View more
  4 in total

1.  Clinical results of an automated artificial pancreas using technosphere inhaled insulin to mimic first-phase insulin secretion.

Authors:  Howard Zisser; Eyal Dassau; Justin J Lee; Rebecca A Harvey; Wendy Bevier; Francis J Doyle
Journal:  J Diabetes Sci Technol       Date:  2015-04-21

2.  Design of the health monitoring system for the artificial pancreas: low glucose prediction module.

Authors:  Rebecca A Harvey; Eyal Dassau; Howard Zisser; Dale E Seborg; Lois Jovanovič; Francis J Doyle
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

3.  Challenges and Recent Progress in the Development of a Closed-loop Artificial Pancreas.

Authors:  B Wayne Bequette
Journal:  Annu Rev Control       Date:  2012-12       Impact factor: 6.091

4.  Value of Capillary Glucose Profiles in Assessing Risk of Nocturnal Hypoglycemia in Type 1 Diabetes Based on Continuous Glucose Monitoring.

Authors:  Qing Ling; Jing Lu; Xiang Li; Chengcheng Qiao; Dalong Zhu; Yan Bi
Journal:  Diabetes Ther       Date:  2020-03-02       Impact factor: 2.945

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.