Literature DB >> 20513341

Practical considerations in the use of real-time continuous glucose monitoring alerts.

John Mastrototaro1, John B Welsh, Scott Lee.   

Abstract

BACKGROUND: The safety and efficacy of real-time (RT) continuous glucose monitoring (CGM) systems in the management of type 1 diabetes are increasingly apparent. Clinical trials have demonstrated the utility of these systems in lowering hemoglobin A1c, minimizing hypoglycemia, and reducing glycemic variability. These RT systems allow patients to conveniently monitor their glucose levels by displaying concentration and trending information. Several of these RT systems provide preset alerts that sound when absolute glucose thresholds are reached. Additionally, some systems allow for predictive algorithm-based alerts that incorporate rates of change. However, clinical trials have identified significant noncompliance in the use of these devices, most notably in the pediatric and adolescent populations. A retrospective review of CGM reports shows that many patients set high and low alert thresholds at levels that result in frequent alerts, potentially resulting in patient nuisance, dismissal of consequential alerts, and eventual product abandonment. Therefore, setting the alert thresholds at appropriate high and low settings can determine the balance between either a perceived benefit by the patient and their long-term use of CGM systems or annoyance to the patient and discontinuation.
CONCLUSION: Care should be taken to set CGM alerts at levels that result in a manageable number of notifications per day. In some cases, providers should consider not using alerts at all or consider using broad targets when initiating CGM to maximize alert specificity. Real-time CGM is safe and generally well tolerated; however, individualization of alert settings is necessary maximize the system's benefits and patient adherence. (c) 2010 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20513341      PMCID: PMC2901052          DOI: 10.1177/193229681000400329

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  18 in total

1.  Improved glycemic control in poorly controlled patients with type 1 diabetes using real-time continuous glucose monitoring.

Authors:  Dorothee Deiss; Jan Bolinder; Jean-Pierre Riveline; Tadej Battelino; Emanuele Bosi; Nadia Tubiana-Rufi; David Kerr; Moshe Phillip
Journal:  Diabetes Care       Date:  2006-12       Impact factor: 19.112

2.  Reduction in hemoglobin A1C with real-time continuous glucose monitoring: results from a 12-week observational study.

Authors:  Timothy S Bailey; Howard C Zisser; Satish K Garg
Journal:  Diabetes Technol Ther       Date:  2007-06       Impact factor: 6.118

3.  Accuracy of a new real-time continuous glucose monitoring algorithm.

Authors:  D Barry Keenan; Raymond Cartaya; John J Mastrototaro
Journal:  J Diabetes Sci Technol       Date:  2010-01-01

Review 4.  Clinical review: Realistic expectations and practical use of continuous glucose monitoring for the endocrinologist.

Authors:  Irl B Hirsch
Journal:  J Clin Endocrinol Metab       Date:  2009-04-21       Impact factor: 5.958

5.  Use of continuous glucose monitoring system in the management of severe hypoglycemia.

Authors:  Edmond A Ryan; Judy Germsheid
Journal:  Diabetes Technol Ther       Date:  2009-10       Impact factor: 6.118

Review 6.  Sensor-augmented pump therapy in type 1 diabetes.

Authors:  Stuart A Weinzimer; William V Tamborlane
Journal:  Curr Opin Endocrinol Diabetes Obes       Date:  2008-04       Impact factor: 3.243

7.  Continuous glucose monitoring and intensive treatment of type 1 diabetes.

Authors:  William V Tamborlane; Roy W Beck; Bruce W Bode; Bruce Buckingham; H Peter Chase; Robert Clemons; Rosanna Fiallo-Scharer; Larry A Fox; Lisa K Gilliam; Irl B Hirsch; Elbert S Huang; Craig Kollman; Aaron J Kowalski; Lori Laffel; Jean M Lawrence; Joyce Lee; Nelly Mauras; Michael O'Grady; Katrina J Ruedy; Michael Tansey; Eva Tsalikian; Stuart Weinzimer; Darrell M Wilson; Howard Wolpert; Tim Wysocki; Dongyuan Xing
Journal:  N Engl J Med       Date:  2008-09-08       Impact factor: 91.245

8.  Effectiveness of continuous glucose monitoring in a clinical care environment: evidence from the Juvenile Diabetes Research Foundation continuous glucose monitoring (JDRF-CGM) trial.

Authors: 
Journal:  Diabetes Care       Date:  2009-10-16       Impact factor: 19.112

9.  Incremental value of continuous glucose monitoring when starting pump therapy in patients with poorly controlled type 1 diabetes: the RealTrend study.

Authors:  Denis Raccah; Véronique Sulmont; Yves Reznik; Bruno Guerci; Eric Renard; Hélène Hanaire; Nathalie Jeandidier; Marc Nicolino
Journal:  Diabetes Care       Date:  2009-09-18       Impact factor: 19.112

10.  Factors predictive of use and of benefit from continuous glucose monitoring in type 1 diabetes.

Authors:  Roy W Beck; Bruce Buckingham; Kellee Miller; Howard Wolpert; Dongyuan Xing; Jennifer M Block; H Peter Chase; Irl Hirsch; Craig Kollman; Lori Laffel; Jean M Lawrence; Kerry Milaszewski; Katrina J Ruedy; William V Tamborlane
Journal:  Diabetes Care       Date:  2009-08-12       Impact factor: 19.112

View more
  9 in total

1.  Hypoglycemia prevention via pump attenuation and red-yellow-green "traffic" lights using continuous glucose monitoring and insulin pump data.

Authors:  Colleen S Hughes; Stephen D Patek; Marc D Breton; Boris P Kovatchev
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

Review 2.  Intensive insulin therapy in critically ill hospitalized patients: making it safe and effective.

Authors:  David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2011-05-01

Review 3.  Utility of different glycemic control metrics for optimizing management of diabetes.

Authors:  Klaus-Dieter Kohnert; Peter Heinke; Lutz Vogt; Eckhard Salzsieder
Journal:  World J Diabetes       Date:  2015-02-15

4.  Clinically relevant hypoglycemia prediction metrics for event mitigation.

Authors:  Rebecca A Harvey; Eyal Dassau; Howard C Zisser; Wendy Bevier; Dale E Seborg; Lois Jovanovič; Francis J Doyle
Journal:  Diabetes Technol Ther       Date:  2012-06-12       Impact factor: 6.118

5.  Long-term sensor-augmented pump therapy for neonatal diabetes mellitus: a case series.

Authors:  Yuya Fukuda; Akira Ishii; Hotaka Kamasaki; Shintaro Fusagawa; Kojiro Terada; Lisa Igarashi; Masaki Kobayashi; Shigeru Suzuki; Takeshi Tsugawa
Journal:  Clin Pediatr Endocrinol       Date:  2022-05-01

6.  Continuous glucose monitoring in children with glycogen storage disease type I.

Authors:  Ç S Kasapkara; G Cinasal Demir; A Hasanoğlu; L Tümer
Journal:  Eur J Clin Nutr       Date:  2013-10-23       Impact factor: 4.016

7.  Healthcare Resource Waste Associated with Patient Nonadherence and Early Discontinuation of Traditional Continuous Glucose Monitoring in Real-World Settings: A Multicountry Analysis.

Authors:  Shengsheng Yu; Biju Varughese; Zhiyi Li; Pam R Kushner
Journal:  Diabetes Technol Ther       Date:  2018-06       Impact factor: 6.118

8.  Practical aspects of diabetes technology use: Continuous glucose monitors, insulin pumps, and automated insulin delivery systems.

Authors:  Brynn E Marks; Kristen M Williams; Jordan S Sherwood; Melissa S Putman
Journal:  J Clin Transl Endocrinol       Date:  2021-12-04

9.  Effectiveness of adding alarms to flash glucose monitoring in adults with type 1 diabetes under routine care.

Authors:  Federico Boscari; Sara Ferretto; Francesco Cavallin; Gian Paolo Fadini; Angelo Avogaro; Daniela Bruttomesso
Journal:  Acta Diabetol       Date:  2022-04-13       Impact factor: 4.087

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.