Literature DB >> 21874100

FEA of CMUTs Suitable for Wide Gas Pressure Range Applications.

Min-Chieh Ho1, Mario Kupnik, Butrus T Khuri-Yakub.   

Abstract

The ability of ultrasound transducers to operate over a wide and varying pressure range is essential in applications such as ultrasonic flow metering (UFM) of flare gas. We propose a new operational mode for capacitive micromachined ultrasonic transducers (CMUTs), in which the plate is in permanent contact with the bottom of the cavity, even at zero DC bias and 1 atm pressure. Finite element analysis (FEA) software was used to investigate the performance of these CMUTs within the pressure range of 1 to 20 atm. First, we performed a static analysis to determine the plate deflection and, thus, the gap height. Further, from the static analysis, we obtained the static and free capacitances for calculating the coupling efficiency, and a modal analysis identified possible design geometries for frequencies lower than ~ 300 kHz. Our calculations show that conventionally operated CMUTs have huge changes in static operational point at different pressures, while our proposed mode exhibits an acceptable frequency range (73 - 340 kHz) over 1 - 20 atm pressure and an improved coupling efficiency at lower dc bias voltages. A donut shape partial electrode further allows us to tune the coupling efficiency, which translates into a better performance, especially at the higher pressure range. FEA shows that our proposed operation mode is a promising solution for flare gas metering applications.

Entities:  

Year:  2010        PMID: 21874100      PMCID: PMC3160643          DOI: 10.1109/ULTSYM.2010.5935678

Source DB:  PubMed          Journal:  Proc IEEE Ultrason Symp        ISSN: 1051-0117


  4 in total

1.  A new regime for operating capacitive micromachined ultrasonic transducers.

Authors:  Baris Bayram; Edward Haeggström; Goksen G Yaralioglu; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-09       Impact factor: 2.725

2.  Linear and nonlinear equivalent circuit modeling of CMUTs.

Authors:  Annette Lohfink; Peter-Christian Eccardt
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-12       Impact factor: 2.725

3.  High-rangeability ultrasonic gas flowmeter for monitoring flare gas.

Authors:  K S Mylvaganam
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1989       Impact factor: 2.725

4.  CMUT Fabrication Based On A Thick Buried Oxide Layer.

Authors:  Mario Kupnik; Srikant Vaithilingam; Kazutoshi Torashima; Ira O Wygant; Butrus T Khuri-Yakub
Journal:  Proc IEEE Ultrason Symp       Date:  2010-10
  4 in total
  1 in total

1.  CMUT Fabrication Based On A Thick Buried Oxide Layer.

Authors:  Mario Kupnik; Srikant Vaithilingam; Kazutoshi Torashima; Ira O Wygant; Butrus T Khuri-Yakub
Journal:  Proc IEEE Ultrason Symp       Date:  2010-10
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.