Literature DB >> 22678597

Relation of fetal heart rate signals with unassignable baseline to poor neonatal state at birth.

A Georgieva1, S J Payne, M Moulden, C W G Redman.   

Abstract

Electronic fetal heart rates (FHR) are used to monitor fetal health during labour. The paper records are visually assessed by clinicians, but automated alternatives are being developed. Interpretation, visual or computerised, depends on assigning a baseline to identify key features such as accelerations and decelerations. However, when the FHR is unstable the baseline may be unassignable, making conventional analysis unreliable. Such instability may reflect on fetal health. If true, these segments should not be discarded but quantified, for which we have developed a numerical method. In 7,568 labours, the association between unassignable baseline and umbilical arterial blood pH ≤ 7.05 at birth (evidence of poor health) was studied retrospectively. We found a consistent increase of the risk for acidaemia with longer intervals of unassignable baseline. This is detectable at the end of the first stage of labour, but stronger at the end of the second stage: in the last 30 min of labour, the odds ratios (with respect to baseline assignable throughout this period) increased from 1.99 (15 min unassignable) to 4.9 (30 min unassignable). Computerised analysis of the FHR becomes unreliable when the baseline cannot be assigned; however, this pattern is itself a pathological feature associated with acidaemia at birth.

Entities:  

Mesh:

Year:  2012        PMID: 22678597     DOI: 10.1007/s11517-012-0923-7

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  21 in total

1.  Twenty-five years after the FIGO guidelines for the use of fetal monitoring: time for a simplified approach?

Authors:  Diogo Ayres-de-Campos; João Bernardes
Journal:  Int J Gynaecol Obstet       Date:  2010-07       Impact factor: 3.561

Review 2.  Use of umbilical cord blood gas analysis in the assessment of the newborn.

Authors:  L Armstrong; B J Stenson
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2007-11       Impact factor: 5.747

3.  ACOG Practice Bulletin No. 106: Intrapartum fetal heart rate monitoring: nomenclature, interpretation, and general management principles.

Authors: 
Journal:  Obstet Gynecol       Date:  2009-07       Impact factor: 7.661

4.  A multicentre comparative study of 17 experts and an intelligent computer system for managing labour using the cardiotocogram.

Authors:  R D Keith; S Beckley; J M Garibaldi; J A Westgate; E C Ifeachor; K R Greene
Journal:  Br J Obstet Gynaecol       Date:  1995-09

5.  Electronic fetal heart rate monitoring and its relationship to neonatal and infant mortality in the United States.

Authors:  Han-Yang Chen; Suneet P Chauhan; Cande V Ananth; Anthony M Vintzileos; Alfred Z Abuhamad
Journal:  Am J Obstet Gynecol       Date:  2011-04-20       Impact factor: 8.661

Review 6.  Communicating the significance of the fetal heart rate record to the user.

Authors:  C W Redman
Journal:  Br J Obstet Gynaecol       Date:  1993-03

Review 7.  Electronic fetal heart rate monitoring: research guidelines for interpretation. National Institute of Child Health and Human Development Research Planning Workshop.

Authors: 
Journal:  Am J Obstet Gynecol       Date:  1997-12       Impact factor: 8.661

Review 8.  Development, evaluation and validation of an intelligent system for the management of labour.

Authors:  R D Keith; K R Greene
Journal:  Baillieres Clin Obstet Gynaecol       Date:  1994-09

9.  Sensitivity and specificity of intrapartum computerised FIGO criteria for cardiotocography and fetal scalp pH during labour: multicentre, observational study.

Authors:  S Schiermeier; S Pildner von Steinburg; A Thieme; J Reinhard; M Daumer; M Scholz; W Hatzmann; K T M Schneider
Journal:  BJOG       Date:  2008-08-25       Impact factor: 6.531

10.  A randomised clinical trial of intrapartum fetal monitoring with computer analysis and alerts versus previously available monitoring.

Authors:  Diogo Ayres-de-Campos; Austin Ugwumadu; Philip Banfield; Pauline Lynch; Pina Amin; David Horwell; Antonia Costa; Cristina Santos; João Bernardes; Karl Rosen
Journal:  BMC Pregnancy Childbirth       Date:  2010-10-28       Impact factor: 3.007

View more
  3 in total

1.  Is Abdominal Fetal Electrocardiography an Alternative to Doppler Ultrasound for FHR Variability Evaluation?

Authors:  Janusz Jezewski; Janusz Wrobel; Adam Matonia; Krzysztof Horoba; Radek Martinek; Tomasz Kupka; Michal Jezewski
Journal:  Front Physiol       Date:  2017-05-16       Impact factor: 4.566

2.  Intrauterine resuscitation during the second stage of term labour by maternal hyperoxygenation versus conventional care: study protocol for a randomised controlled trial (INTEREST O2).

Authors:  Lauren M Bullens; Alexandra D J Hulsenboom; Suzanne Moors; Rohan Joshi; Pieter J van Runnard Heimel; M Beatrijs van der Hout-van der Jagt; Edwin R van den Heuvel; S Guid Oei
Journal:  Trials       Date:  2018-03-23       Impact factor: 2.279

Review 3.  Approaches to Preventing Intrapartum Fetal Injury.

Authors:  Barry S Schifrin; Brian J Koos; Wayne R Cohen; Mohamed Soliman
Journal:  Front Pediatr       Date:  2022-09-23       Impact factor: 3.569

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.