Literature DB >> 22667684

An in vitro fluid dynamic study of pediatric cannulae: the value of animal studies to predict human flow.

Tobias C Long1, Joseph J Pearson, Andrew C Hankinson, Steven Deutsch, Keefe B Manning.   

Abstract

A challenge to the development of pediatric ventricular assist devices (PVADs) is the use of the aortic cannulae attached to the devices. Cannulae used for pediatric application have small diameters and large pressure drops. Furthermore, during the development of the 12cc Penn State pediatric PVAD, particle image velocimetry (PIV) illustrated that hematocrit levels, through changes in blood viscoelasticity, affected the fluid dynamics. The objective of this study is to compare the fluid dynamics of a pediatric viscoelastic blood analog and a goat viscoelastic blood analog within the PVAD aortic cannula. Two acrylic models were manufactured to model the aortic cannula (6 mm and 8 mm diameters). PIV data was collected to examine the flow at the outlet of the VAD and in the aortic cannula at heart rates of 50 and 75 beats per minute (bpm). Three planes of data were taken, one at the centerline and two 1.5 mm above and below the centerline. Three more planes of data were taken orthogonal to the original planes. While a 75 bpm heart rate was used to represent normal operating conditions, a 50 bpm heart rate represented use of the PVAD during weaning. At 75 bpm, differences were evident between the two different fluids and the two models. Separation zones developed in the plane below the centerline for the higher hematocrit pediatric blood analog. This study raises question to the usefulness of animal testing results in regard to how well they predict the outcome of pediatric patients.

Entities:  

Mesh:

Year:  2012        PMID: 22667684      PMCID: PMC3705856          DOI: 10.1115/1.4006428

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  17 in total

1.  Hemodynamic comparison of two different pediatric aortic cannulas.

Authors:  D De Wachter; F De Somer; P Verdonck
Journal:  Int J Artif Organs       Date:  2002-09       Impact factor: 1.595

2.  The National Heart, Lung, and Blood Institute Pediatric Circulatory Support Program.

Authors:  J Timothy Baldwin; Harvey S Borovetz; Brian W Duncan; Mark J Gartner; Robert K Jarvik; William J Weiss; Tracey R Hoke
Journal:  Circulation       Date:  2006-01-03       Impact factor: 29.690

3.  Pediatric bridge to heart transplantation: application of the Berlin Heart, Medos and Thoratec ventricular assist devices.

Authors:  Francisco A Arabía; Pei H Tsau; Richard G Smith; Paul E Nolan; Venki Paramesh; Raj K Bose; Daniel S Woolley; Gulshan K Sethi; Birger E Rhenman; Jack G Copeland
Journal:  J Heart Lung Transplant       Date:  2005-11-18       Impact factor: 10.247

4.  Viscoelasticity of pediatric blood and its implications for the testing of a pulsatile pediatric blood pump.

Authors:  Jennifer A Long; Akif Undar; Keefe B Manning; Steven Deutsch
Journal:  ASAIO J       Date:  2005 Sep-Oct       Impact factor: 2.872

5.  Flow characteristics of aortic cannulae.

Authors:  D D Muehrcke; J F Cornhill; J D Thomas; D M Cosgrove
Journal:  J Card Surg       Date:  1995-07       Impact factor: 1.620

6.  Improvement in survival after mechanical circulatory support with pneumatic pulsatile ventricular assist devices in pediatric patients.

Authors:  Roland Hetzer; Evgenij V Potapov; Brigitte Stiller; Yuguo Weng; Michael Hübler; Julia Lemmer; Vladimir Alexi-Meskishvili; Matthias Redlin; Frank Merkle; Friedrich Kaufmann; Ewald Hennig
Journal:  Ann Thorac Surg       Date:  2006-09       Impact factor: 4.330

7.  One-month biocompatibility evaluation of the pediatric TinyPump in goats.

Authors:  Yusuke Ando; Takashi Kitao; Eiki Nagaoka; Taro Kimura; Yoshimasa Yokoyama; Masaharu Yoshikawa; Ryuji Tominaga; Setsuo Takatani
Journal:  Artif Organs       Date:  2011-08       Impact factor: 3.094

8.  Left ventricular assist system as a bridge to myocardial recovery.

Authors:  O H Frazier; T J Myers
Journal:  Ann Thorac Surg       Date:  1999-08       Impact factor: 4.330

9.  Low incidence of myocardial recovery after left ventricular assist device implantation in patients with chronic heart failure.

Authors:  D M Mancini; A Beniaminovitz; H Levin; K Catanese; M Flannery; M DiTullio; S Savin; M E Cordisco; E Rose; M Oz
Journal:  Circulation       Date:  1998-12-01       Impact factor: 29.690

10.  Improved left ventricular function after chronic left ventricular unloading.

Authors:  O H Frazier; C R Benedict; B Radovancevic; R J Bick; P Capek; W E Springer; M P Macris; R Delgado; L M Buja
Journal:  Ann Thorac Surg       Date:  1996-09       Impact factor: 4.330

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.