Literature DB >> 22666837

Color stability, surface roughness and microhardness of composites submitted to mouthrinsing action.

Marília Salomão Campos Cabrini Festuccia1, Lucas da Fonseca Roberti Garcia, Diogo Rodrigues Cruvinel, Fernanda de Carvalho Panzeri Pires-De-Souza.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate the effect of mouth rinse solutions on color stability, surface roughness and microhardness of two composite resins.
MATERIAL AND METHODS: Fifty test specimens of each composite (Filtek Z250 and Z350; 3M ESPE) were made using a teflon matrix (12x2 mm). Color, surface roughness and Knoop microhardness baseline measurements of each specimen were made and specimens (n=10) were immersed in 5 mouth rinse solutions: G1: distilled water (control), G2: Plax Classic, G3: Plax alcohol-free; G4: Periogard, and G5: Listerine. Final measurements of color, roughness and microhardness were performed and the results submitted to statistical analysis (2-way ANOVA, Bonferroni's test; p<0.05).
RESULTS: The most significant color change was observed for Z250 when immersed in Listerine (p<0.05). Z350 showed greater color change when immersed in Plax alcohol-free (p<0.05), but with no significant difference for Listerine (p>0.05). With regard to roughness, both composites showed significant changes when immersed in Listerine in comparison with Plax alcohol-free (p<0.05). Microhardness of Z350 was shown to be significantly changed when the composite was immersed in Plax alcohol-free (p<0.05).
CONCLUSION: Composite changes depended on the material itself rather than the mouth rinse solution used.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22666837      PMCID: PMC3894763          DOI: 10.1590/s1678-77572012000200013

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


INTRODUCTION

Color and surface roughness are very important properties in aesthetics, characterizing a smile[21]. Since the introduction of composites in 1960, efforts have been made to increase the longevity of composite restorations. Although some progress has been made, optical properties in this type of materials need to be improved[5]. The color change of composites is multifactorial, being associated with intrinsic discoloration and extrinsic staining of the material. Intrinsic factors involve changes in the chemical stability of resin matrix and matrix/particles interface, and extrinsic factors are related to absorption of staining solutions from exogenous sources related to hygiene habits, food, and smoking[8]. Composite structure and the characteristics of the inorganic fillers have a direct impact on composite resin surface smoothness[26] and susceptibility to extrinsic staining[24]. Several studies have shown that composite resins are susceptible to color alteration when exposed to staining solutions, especially red wine, coffee, cola, tea and whisky[2,9]. Furthermore, this property depends on both water absorption of the composite and its hydrophilic resin matrix to allow permeation of staining agents, thus resulting in greater color changes[2]. Today, the number of people using mouth rinse solutions for anti-microbial control has increased not only because of professional recommendations, but also due to the capacity of such materials to provide cooling sensation and to reduce halitosis[7]. Mouth rinse solutions have various components such as detergents, emulsifiers, organic acids, dyes and alcohol. It is known that composite resins exposed to ethanol exhibit lower microhardness values compared to non-exposed materials[23]. According to Sarret, et al.[22 ](2000), alcohol acts as a plasticizer of the polymeric matrix, making the material more ductile. In addition, ethanol can reduce bonding between resin matrix and inorganic fillers, which might decrease erosion resistance and cause staining of resin matrix[23]. Thus, the purpose of this study was to evaluate the effect of mouth rinse solutions on color stability, surface roughness and microhardness of composite resins. The null hypothesis stated that mouth rinse solutions would not promote changes in the properties of the studied composites.

MATERIAL AND METHODS

Samples preparation

Two direct composite resins (shade A3) currently indicated for esthetic anterior and posterior restorations were used in the present study. Information regarding composite type, composition and manufacturer is given in Figure 1.
Figure 1

Tested composites

Commercial nameTypeMonomersLoad particlesManufacturer
Size (µm)Volume %
Filtek Z250MicrohybridBis-GMA, UDMA, Bis-EMAZirconia/Silica 0.6 jm60%3M ESPE Dental Products, St Paul, MN, USA
Filtek Z350NanoparticulateBis-GMA, Bis- EMA, UDMA and TEGDMAZirconia/Silica 5-20 nm with clusters of 0.6-1.4 jm59.5%3M ESPE Dental Products, St Paul, MN, USA

Bis-GMA: bisphenol A diglycidyl ether dimethacrylate; Bis-EMA: Ethoxylated bisphenol A dimethacrylate, TEGDMA:Triethylene glycol dimethacrylate; UDMA: urethane dimethacrylate

Tested composites Bis-GMA: bisphenol A diglycidyl ether dimethacrylate; Bis-EMA: Ethoxylated bisphenol A dimethacrylate, TEGDMA:Triethylene glycol dimethacrylate; UDMA: urethane dimethacrylate Fifty cylindrical test specimens (12 mm diameter x 2 mm thick) of each composite were made using a Teflon matrix. Each material was inserted into the matrix in 2 increments and light-activated by a LED device (FLASHlite 1401, Discus Dental, Culver City, CA, USA, light intensity ≥1100 mW/cm2, wavelength in the range between 460 and 480 nm), for 20 seconds, according to manufacturer's recommendations. The specimens were polished with 320, 600, 1200 and 2000-grit sandpapers. The thickness of every test specimen was checked with a digital caliper (Digimess, São Paulo, SP, Brazil). Next, the test specimens were randomly separated into 5 groups (n=10) according to the mouth rinse solution in which they had been immersed (Figure 2): Group 1 - distilled water (control); Group 2 - Plax classic; Group 3 - Plax alcohol-free; Group 4 - Periogard; and Group 5 - Listerine Cool Mint.
Figure 2

Tested mouth rinses

Commercial nameCompositionpHManufacturer
Plax ClassicTriclosan, Gantrez, Sodium lauryl sulphate, Glycerin and Propylene, Sodium fluoride (225 ppm fluoride), Sodium methyl taurate, Disodium phosphate, Sodium saccharine, red dye, ethylic alcohol (6%) and water5.8Colgate Palmolive Ind. e Com. Ltda., São Bernardo do Campo, SP, Brazil
Plax Alcohol-freeCetyl Pyridinium Chloride (CPC) 0.05 % 225 ppm fluoride, Gantrez, Sodium lauryl sulphate, Glycerin and Propylene, Sodium methyl taurate, phosphoric acid, Disodium phosphate, Sodium saccharine and water4.96Colgate Palmolive Ind. e Com. Ltda., São Bernardo do Campo, SP, Brazil
Periogard0.12% gluconate (or digluconate formulation with chlorhexidine-free concentration (0.067%), water, glycerin, ethanol, polysorbate 20, aromatic composition with predominant flavor of mint, sodium saccharine, FD&C blue dye #15.0-7.0Colgate Palmolive Ind. e Com. Ltda., São Bernardo do Campo, SP, Brazil
Listerine Cool MintThymol, eucalyptol, methyl salicylate, menthol, excipients: purified water, sorbitol solution, alcohol (30%), poloxamer 407, benzoic acid, mint essence, sodium saccharine, sodium benzoate, green dye #33.7Laboratório Pfizer Ltda., São Paulo, SP, Brazil
Tested mouth rinses To simulate the use of mouth rinse solutions once a day during a period of 1 year, the test specimens were submitted to 12 cycles of 1-min immersion, then washed in running water and immersed in distilled water for 29 min at 37ºC, during 30 days, totaling 360 cycles[11].

Color stability

Before immersion, color reading of the test specimens was performed according to the CIE (Commission Internationale de l'Eclairage) L*a*b* system, against a white background (Standard for 45/0º; Gardner Laboratory Inc., Bethesda, MD, USA) in a reflection spectrophotometer (PCB 6807, BYK Gardner, Geretsried, Germany). This equipment is specific for color reading and has 30 LED lamps with 10 different colors arranged in a circle, which directs a light bundle at 45º with the material surface. This light bundle is reflected 0º back to the equipment, which captures and records the L*, a* and b* values of each specimen. The L* axes refers to the lightness coordinate and its value ranges from zero (black) to 100 (white). The axis a* and b* are chromaticity coordinates in the red-green axis and the yellow-blue axis, respectively. Positive a* values indicate a shift to red and negative values indicate a shift to green. Similarly, positive b* values indicate the yellow color range and negative values indicate the blue color range. After immersion in mouth rinse solutions, specimens color was measured by the spectrophotometer, as previously described. Based on the L*, a*, b* values, color variation (DE) was determined using the following equation: ΔE=[(ΔL*)2+(Δa*)2+(Δb*)2]1/2 Values of ΔE≥3.3 were considered clinically unacceptable[20].

Surface roughness and Knoop microhardness

Surface roughness (Ra) and Knoop microhardness of the test specimens were performed before and after mouth rinse solution immersion. Surface roughness was measured with a Rugosimeter (Mitutoyo SJ-201P, Mitutoyo, Tokyo, Japan), cut-off - 0.25 mm, Lc parameter - 1.25, speed - 0.1 mm/s. The rugosimeter needle (10 µm diameter) was positioned over each test specimen, performing three readings in different locations of the sample surface, after which, the mean roughness of the test specimens were obtained. Surface roughness changes were calculated by the differences between mean values obtained before and after immersion. The Knoop microhardness of the test specimens was measured (Shimadzu device, HMV Shimadzu, Kyoto, Japan) in three different points, with a 10 N/15 s load. After three readings, the microhardness mean values of the test specimens were obtained. For Knoop microhardness calculation, the baseline mean values were subtracted from those obtained after immersion.

Statistical analysis

For each property, data obtained were subjected to two-way ANOVA and the measurements were compared by the Bonferroni's test. All statistical testing was performed at a pre-set alpha of 0.05.

RESULTS

The mean values and standard deviations for color stability (ΔE) changes are presented in Table 1. None of the studied composites exhibited color change with values above the clinically acceptable limit (ΔE≥3.3)[20]. With regard to Z250, comparison of the effects of different mouth rinse solutions revealed a small color change for specimens immersed in Listerine, with statistically significant difference compared with the other mouth rinse solutions (p<0.05). When immersed in Plax Classic solution, this composite exhibited an intermediate DE value without statistically significant difference compared to other mouth rinse solutions (p>0.05). With regard to Z350, the highest DE change was observed for Plax alcohol-free solution, with statistically significant difference compared with the other solutions (p>0.05), except for Listerine. Comparing the composites to each other, it was observed statistically significant difference (p<0.05) for the test specimens immersed in distilled water (control), with both Plax Classic and Periogard solutions allowing smaller color changes for Z350.
Table 1

Means (standard deviations) for ΔE values (2-way ANOVA, Bonferroni's test; p<0.05)

 Z250Z350
Control1.52 (0.37)a,A 0.96 (0.24)b,AB
Listerine0.99 (0.29)a,B 1.25 (0.24)a,AC
Plax Classic 1.32 (0.46)a,AB0.64 (0.23)b,B
Plax alchohol-free1.42 (0.45)a,A1.46 (0.30)a,C
Periogard1.40 (0.71)a,A 0.93 (0.16)b,AB

Different lowercase letters in lines and uppercase letters in columns indicate statistically significant difference.

Means (standard deviations) for ΔE values (2-way ANOVA, Bonferroni's test; p<0.05) Different lowercase letters in lines and uppercase letters in columns indicate statistically significant difference.

Surface roughness

The mean values and standard deviations for surface roughness (Ra) changes are presented in Table 2. For both composites, the greatest change in Ra occurred when the samples were immersed in Listerine solution, with statistically significant difference compared with Plax alcohol-free (p<0.05). When compared to each other, Z250 and Z350, showed no statistically significant difference (p>0.05) regarding any studied mouth rinse solution.
Table 2

Means (standard deviations) for Ra (%) values (2-way ANOVA, Bonferroni's test; p<0.05)

 Z250Z350
Control44.94 (0.34)a,A27.60 (0.28)a,A
Listerine78.46 (0.56)a,AB61.99 (0.53)a,AB
Plax Classic38.28 (0.18)a,A 13.36 (0.18)a,A
Plax alcohol-free -4.22 (0.20)a,AC -10.76 (0.27)a,AC
Periogard 64.43 (0.46)a,AB58.22 (0.34)a,AB

Different lowercase letters in lines and uppercase letters in columns indicate statistically significant difference.

Means (standard deviations) for Ra (%) values (2-way ANOVA, Bonferroni's test; p<0.05) Different lowercase letters in lines and uppercase letters in columns indicate statistically significant difference.

Knoop microhardness

The mean values and standard deviations for Knoop microhardness changes are presented in Table 3. When compared to each other, Z250 and Z350 showed no statistically significant difference (p>0.05) regarding any studied mouth rinse solution. Immersion of Z350 in Plax alcohol-free solution resulted in greater decrease of microhardness values, with statistically significant difference in relation to the other mouth rinse solutions (p<0.05).
Table 3

Means (standard deviations) for Knoop microhardness (%) values (2-way ANOVA, Bonferroni's test; p<0.05)

 Z250Z350
Control 7.30 (0.17)a,A22.28 (0.18)a,A
Listerine -14.88 (0.10)a,A1.20 (0.27)a,A
Plax Classic -6.98 (0.08)a,A 15.83 (0.40)a,A
Plax alcohol-free -5.03 (0.23)a,A -25.73 (0.19)a,B
Periogard -0.24 (0.18)a,A 14.80 (0.24)a,A

Different lowercase letters in lines and uppercase letters in columns indicate statistically significant difference.

Means (standard deviations) for Knoop microhardness (%) values (2-way ANOVA, Bonferroni's test; p<0.05) Different lowercase letters in lines and uppercase letters in columns indicate statistically significant difference.

DISCUSSION

The variability in our results was consistent with other studies, which showed that several factors, including composite resin type, mouth rinse solution and immersion cycle, had a significant influence on color stability, surface roughness and microhardness of composites[28]. Therefore, the null hypothesis could not be accepted. Color stability can be evaluated both visually and by specific instruments[5,8,11]. The methodology used in the present study is according to previous studies that used spectrophotometry and the CIE L*a*b* coordinates system[5,11]. The CIE L*a*b* system was chosen to evaluate color variation (DE) because it is appropriate for small color changes determination and have advantages such as repeatability, sensitivity and objectivity[11]. Several authors have reported that ΔE values ranging from 1 to 3 are perceptible to the naked eye[18] and ΔE values greater than 3.3 are clinically unacceptable[20]. Considering these concepts; the composite resins tested in the present study demonstrated acceptable color stability when stored in the different types of mouth rinse solutions (Table 1). The affinity of the resin matrix for stains is modulated by its conversion degree and by some physical properties, such as water sorption[2,6]. Water sorption of composite resins depends on the resinous matrix composition. It has been reported that water uptake in Bis-GMA based composite resins increased from 3 to 6%, as the proportion of TEGDMA increased from 0 to 1%[13]. UDMA seems to be more stain resistant than Bis-GMA[15], and under normal curing conditions, UDMA based composite resins presented lower water sorption and higher color stability than other dimethacrylates in their resin matrix[15,20], which could be observed in the present study. Moreover, it is important that the composite resin presents uniform filler particle distribution in the polymer network to minimize the formation of filler-rich and filler-depleted areas within the composites. This is especially important regarding the performance of composites in aqueous environments, such as mouth rinse solutions, since voids or nonbonding spaces at the filler/matrix interface may increase the water sorption of composites[25]. Nanocomposites correspond to a class of new materials with nanoscale inorganic filler particles dispersed within the resinous matrix[27]. In comparison with microhybrid composites, these materials have been reported to have improved properties, such as, elasticity modulus, mechanical strength and color stability. Furthermore, these improvements are achieved at low concentrations of the inorganic filler particles. This fact contrasts strongly with conventional filled composites, which generally require high loadings within the range of 60%[11,19]. This is an important factor in aesthetic maintenance of non-particulate composites, since filler particles are responsible for spreading the light, which in turn, provides the opacity of the restorative resin materials. The larger the filler particle size the greater the light spread, and consequently, the greater the opacity[16]. The opacity of composites increases as the difference between the refraction indexes of resinous matrix and filler particles also increases[16]. In addition, the smaller the filler particle, the smaller the amount of water absorbed by the polymer network, which results in lower degradation of the interface matrix/particle, and consequently, lower color change[10]. The Z250 contains filler particles with average size of 0.6 µm, while Z350 contains filler particles ranging from 5 to 20 nm, which could explain the greater color stability for Z350[29]. Also, according to Kawaguchi, et al.[14 ](1994), microhybrid composites present a lower coefficient of light transmission due to the various sizes of their particles, which contributed to the higher values of ΔE for Z250. According to Villalta, et al.[30 ](2006), the low pH and alcohol concentration of solutions affect the surface roughness of composite resins and cause staining. Nevertheless, the composite Z350 presented statistically significant difference regarding color stability, surface roughness and microhardness values when the composite was immersed in the alcohol-free mouth rinse solution (Plax alcohol-free), thus contradicting the results of a previous study[30]. However, Miranda, et al.[17] (2011) demonstrated that despite the absence of alcohol, Plax alcohol-free has phosphoric acid in its composition, which might alter the polymer matrix of composites by catalysis of the ester groups present in the dimethacrylate monomers. The hydrolysis of the ester groups forms alcohol and carboxylic acid molecules, which accelerate polymer network degradation by the decrease of pH inside the composite matrix[10,17]. The degradation of the polymer network leads to a phenomenon called "plasticization", which decreases microhardness values in composites[10]. According to the methodology used in the present study, the negative values regarding microhardness represent a smoothening of the resin matrix, and positive values, hardening. Despite the great decrease in the composite microhardness (-25.73), the surface roughness improved when compared to the pre-immersion values, except when the composite was immersed in the Plax alcohol-free solution. The same result was observed for Z250, since a significant change in surface roughness was found after immersion into the same mouth rinse solution. It is worth emphasizing, however, that there exists a critical value regarding surface roughness change (Ra≥0.2 µm). According to Bollen, et al.[3 ](1997), a greater biofilm retention allows an increase in recurrent caries. Another critical value for Ra is 0.3 µm, which can be detected when the patient's lips or tongue enters in contact with the restorative material, causing discomfort[3]. None of the studied composites showed values for surface roughness change above the critical limits, irrespective of the type of mouth rinse solution used. Asmussen[1] (1984) reported that mouth rinse solutions with high alcohol content might soften the composite resin, especially Bis-GMA-based composites. However, Gürgan, et al.[12] (1997) showed that regardless of the alcohol concentration, both alcohol-containing and alcohol-free mouth rinse solutions could affect the properties of composite resins. Immersed of Z350 in Listerine, the mouth rinse solution with the highest alcohol concentration (30%), resulted in decrease in microhardness values, though with no significant difference from the other mouth rinse solutions. As for Z250, the results were the opposite; there was an increase in the microhardness values when immersed in Listerine and a decrease when immersed in Plax alcohol-free solution, with statistically significant difference. These results suggest that changes in the microhardness of composites do not depend on mouth rinse's ethanol concentration[12]. The same finding could be observed regarding to color stability. Z350 showed significant changes when immersed in Listerine and Plax alcohol-free solutions, both having entirely different concentrations of ethanol[12]. However, this fact could be explained, once again, by the presence of phosphoric acid in Plax alcohol-free composition. Studies have reported the release of by-products from polymer network degradation, such as methacrylic acid, formaldehyde and specific methacrylate molecules, which are capable of promoting color change in composites[4,10,17]. On the other hand, Z250 had greater color change when immersed in Listerine compared to the other solutions, unlike Celik, et al.[4] (2008), who found no color change in the composites immersed in the same mouth rinse solution, despite the high ethanol concentration. Clinically, the effect of mouth rinse solutions on restorative materials can be modified by several factors that were not replicated in this in vitro study. Among these factors, saliva could dilute or buffer pH of mouth rinse solutions, thus reducing the effect of resinous matrix plasticization[10] and forming a pellicle that could have a protective effect on the composite surface, thus, decreasing material staining[4]. Based on such factors, further in vivo studies are needed to determine the effects of mouth rinse solutions on these properties of composites.

CONCLUSIONS

The results of the present study allow us to conclude that the changes observed in the composites depended on the material itself rather than the mouth rinse solution used.
  29 in total

1.  Nanotechnology in dentistry: reduction to practice.

Authors:  David Ure; Jonathan Harris
Journal:  Dent Update       Date:  2003 Jan-Feb

2.  The effects of mouthrinses on microhardness and colour stability of aesthetic restorative materials.

Authors:  P Gürdal; B Günz Akdeniz; B Hakan Sen
Journal:  J Oral Rehabil       Date:  2002-09       Impact factor: 3.837

3.  Color and opacity variations in three different resin-based composite products after water aging.

Authors:  Alessandro Vichi; Marco Ferrari; Carel Leon Davidson
Journal:  Dent Mater       Date:  2004-07       Impact factor: 5.304

4.  Influence of filler on the difference between the transmitted and reflected colors of experimental resin composites.

Authors:  Yong-Keun Lee
Journal:  Dent Mater       Date:  2008-03-17       Impact factor: 5.304

5.  Color stability of restorative resins.

Authors:  Z A Khokhar; M E Razzoog; P Yaman
Journal:  Quintessence Int       Date:  1991-09       Impact factor: 1.677

6.  Color stability of dental composite resin materials for crown and bridge veneers.

Authors:  I E Ruyter; K Nilner; B Moller
Journal:  Dent Mater       Date:  1987-10       Impact factor: 5.304

7.  The relationship between cure depth and transmission coefficient of visible-light-activated resin composites.

Authors:  M Kawaguchi; T Fukushima; K Miyazaki
Journal:  J Dent Res       Date:  1994-02       Impact factor: 6.116

8.  Color dye for identification of incompletely cured composite resins.

Authors:  A J de Gee; E ten Harkel-Hagenaar; C L Davidson
Journal:  J Prosthet Dent       Date:  1984-11       Impact factor: 3.426

9.  Effects of mouthwashes on Knoop hardness and surface roughness of dental composites after different immersion times.

Authors:  Diogo de Azevedo Miranda; Carlos Eduardo Dos Santos Bertoldo; Flávio Henrique Baggio Aguiar; Débora Alves Nunes Leite Lima; José Roberto Lovadino
Journal:  Braz Oral Res       Date:  2011 Mar-Apr

10.  Softening of BISGMA-based polymers by ethanol and by organic acids of plaque.

Authors:  E Asmussen
Journal:  Scand J Dent Res       Date:  1984-06
View more
  12 in total

1.  Influence of brushing with natural dentifrices on color change: In vitro study.

Authors:  Helena Dutra; Isabel Barbosa; João-Victor Câmara; Gisele Pereira
Journal:  J Clin Exp Dent       Date:  2021-08-01

2.  The effect of phytosphingosine associated with tooth brushing on color change, surface roughness, and microhardness of dental enamel - an in vitro and in situ study.

Authors:  Carolina Noronha Ferraz de Arruda; Rocio Geng Vivanco; Ayodele Alves Amorim; Adriana Cavalcanti Ferreira; Rafaella Tonani-Torrieri; Floris Jacob Bikker; Fernanda de Carvalho Panzeri Pires-de-Souza
Journal:  Clin Oral Investig       Date:  2022-07-13       Impact factor: 3.606

3.  Effects of bioflavonoid-containing mouth rinses on optical properties of tooth-coloured dental restorative materials.

Authors:  Tihana Divnic-Resnik; Jay Junyang Shen; Jim Vinh The Nguyen; Derek Weidi Lu; Vesna Miletic
Journal:  Sci Rep       Date:  2022-06-15       Impact factor: 4.996

4.  Influence of restorative material translucency on the chameleon effect.

Authors:  Tanaporn Vattanaseangsiri; Areeyabhorn Khawpongampai; Pornpitcha Sittipholvanichkul; Nawaporn Jittapiromsak; Sumana Posritong; Kornchanok Wayakanon
Journal:  Sci Rep       Date:  2022-05-25       Impact factor: 4.996

5.  Comparative Evaluation of Colour Stability and Surface Hardness of Methacrylate Based Flowable and Packable Composite -In vitro Study.

Authors:  Saron Ramesh Nair; Nandini Thipannanavar Niranjan; Arun Jayasheel; Deepak Bythnal Suryakanth
Journal:  J Clin Diagn Res       Date:  2017-03-01

6.  Influence of mouth rinses on the surface hardness of dental resin nano-composite.

Authors:  Aftab Ahmed Khan; Adel Zia Siddiqui; Syed Fareed Mohsin; Abdulaziz A Al-Kheraif
Journal:  Pak J Med Sci       Date:  2015 Nov-Dec       Impact factor: 1.088

7.  Color Stability of Nanofilled and Microhybrid Resin-Based Composites Following Exposure to Chlorhexidine Mouthrinses: An In Vitro Study.

Authors:  Mahmood Khosravi; Behnaz Esmaeili; Forough Nikzad; Soraya Khafri
Journal:  J Dent (Tehran)       Date:  2016-03

8.  Effects of protective resin coating on the surface roughness and color stability of resin-based restorative materials.

Authors:  Bora Bagis; Tamer Tüzüner; Sedanur Turgut; Fatih Mehmet Korkmaz; Özgül Baygın; Yıldırım Hakan Bağış
Journal:  ScientificWorldJournal       Date:  2014-08-05

9.  Mouthrinses affect color stability of composite.

Authors:  Arshia Rashid Baig; Deepa Deepak Shori; Pratima Ramakrishna Shenoi; Syed Navid Ali; Sanjay Shetti; Alkesh Godhane
Journal:  J Conserv Dent       Date:  2016 Jul-Aug

10.  Effect of a novel commercial potassium-oxalate containing tooth-desensitizing mouthrinse on the microhardness of resin composite restorative materials with different monomer compositions.

Authors:  Barış Karabulut; Deniz C Can-Karabulut; Serkan Güleç; Cem M Doğan
Journal:  J Clin Exp Dent       Date:  2016-12-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.