Literature DB >> 22655019

High-performance microfluidic rectifier based on sudden expansion channel with embedded block structure.

Chien-Hsiung Tsai, Che-Hsin Lin, Lung-Ming Fu, Hui-Chun Chen.   

Abstract

A high-performance microfluidic rectifier incorporating a microchannel and a sudden expansion channel is proposed. In the proposed device, a block structure embedded within the expansion channel is used to induce two vortex structures at the end of the microchannel under reverse flow conditions. The vortices reduce the hydraulic diameter of the microchannel and, therefore, increase the flow resistance. The rectification performance of the proposed device is evaluated by both experimentally and numerically. The experimental and numerical values of the rectification performance index (i.e., the diodicity, Di) are found to be 1.54 and 1.76, respectively. Significantly, flow rectification is achieved without the need for moving parts. Thus, the proposed device is ideally suited to the high pressure environment characteristic of most micro-electro-mechanical-systems (MEMS)-based devices. Moreover, the rectification performance of the proposed device is superior to that of existing valveless rectifiers based on Tesla valves, simple nozzle/diffuser structures, or cascaded nozzle/diffuser structures.

Year:  2012        PMID: 22655019      PMCID: PMC3360723          DOI: 10.1063/1.4704504

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  28 in total

1.  A microfluidic rectifier: anisotropic flow resistance at low Reynolds numbers.

Authors:  Alex Groisman; Stephen R Quake
Journal:  Phys Rev Lett       Date:  2004-03-04       Impact factor: 9.161

2.  On-chip collection of particles and cells by AC electroosmotic pumping and dielectrophoresis using asymmetric microelectrodes.

Authors:  Elizabeth M Melvin; Brandon R Moore; Kristin H Gilchrist; Sonia Grego; Orlin D Velev
Journal:  Biomicrofluidics       Date:  2011-08-10       Impact factor: 2.800

3.  Fluid flow due to collective non-reciprocal motion of symmetrically-beating artificial cilia.

Authors:  S N Khaderi; J M J den Toonder; P R Onck
Journal:  Biomicrofluidics       Date:  2012-01-20       Impact factor: 2.800

4.  Microtubule transport, concentration and alignment in enclosed microfluidic channels.

Authors:  Ying-Ming Huang; Maruti Uppalapati; William O Hancock; Thomas N Jackson
Journal:  Biomed Microdevices       Date:  2007-04       Impact factor: 2.838

5.  Syringe-vacuum microfluidics: A portable technique to create monodisperse emulsions.

Authors:  Adam R Abate; David A Weitz
Journal:  Biomicrofluidics       Date:  2011-03-16       Impact factor: 2.800

6.  Whole blood pumping with a microthrottle pump.

Authors:  M J Davies; I D Johnston; C K L Tan; M C Tracey
Journal:  Biomicrofluidics       Date:  2010-12-23       Impact factor: 2.800

7.  Review Article: Recent advancements in optofluidic flow cytometer.

Authors:  Sung Hwan Cho; Jessica M Godin; Chun-Hao Chen; Wen Qiao; Hosuk Lee; Yu-Hwa Lo
Journal:  Biomicrofluidics       Date:  2010-12-30       Impact factor: 2.800

8.  Characterization of a microflow cytometer with an integrated three-dimensional optofluidic lens system.

Authors:  M Rosenauer; M J Vellekoop
Journal:  Biomicrofluidics       Date:  2010-12-30       Impact factor: 2.800

9.  High-throughput size-based rare cell enrichment using microscale vortices.

Authors:  Soojung Claire Hur; Albert J Mach; Dino Di Carlo
Journal:  Biomicrofluidics       Date:  2011-06-29       Impact factor: 2.800

10.  Swimming direction reversal of flagella through ciliary motion of mastigonemes.

Authors:  S Namdeo; S N Khaderi; J M J den Toonder; P R Onck
Journal:  Biomicrofluidics       Date:  2011-07-29       Impact factor: 2.800

View more
  6 in total

1.  Experimental characterisation of a novel viscoelastic rectifier design.

Authors:  Kristian Ejlebjerg Jensen; Peter Szabo; Fridolin Okkels; M A Alves
Journal:  Biomicrofluidics       Date:  2012-12-10       Impact factor: 2.800

2.  A hydrodynamic focusing microchannel based on micro-weir shear lift force.

Authors:  Ruey-Jen Yang; Hui-Hsiung Hou; Yao-Nan Wang; Che-Hsin Lin; Lung-Ming Fu
Journal:  Biomicrofluidics       Date:  2012-08-06       Impact factor: 2.800

3.  Microfluidic rectifier based on poly(dimethylsiloxane) membrane and its application to a micropump.

Authors:  Yao-Nan Wang; Chien-Hsiung Tsai; Lung-Ming Fu; Lung-Kai Lin Liou
Journal:  Biomicrofluidics       Date:  2013-08-14       Impact factor: 2.800

4.  Lattice Boltzmann numerical simulation and experimental research of dynamic flow in an expansion-contraction microchannel.

Authors:  Di Jiang; Dongke Sun; Nan Xiang; Ke Chen; Hong Yi; Zhonghua Ni
Journal:  Biomicrofluidics       Date:  2013-06-26       Impact factor: 2.800

5.  Optimization of microfluidic microsphere-trap arrays.

Authors:  Xiaoxiao Xu; Pinaki Sarder; Zhenyu Li; Arye Nehorai
Journal:  Biomicrofluidics       Date:  2013-02-27       Impact factor: 2.800

6.  Convenient quantification of methanol concentration detection utilizing an integrated microfluidic chip.

Authors:  Yao-Nan Wang; Ruey-Jen Yang; Wei-Jhong Ju; Ming-Chang Wu; Lung-Ming Fu
Journal:  Biomicrofluidics       Date:  2012-08-13       Impact factor: 2.800

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.