Literature DB >> 17195111

Microtubule transport, concentration and alignment in enclosed microfluidic channels.

Ying-Ming Huang1, Maruti Uppalapati, William O Hancock, Thomas N Jackson.   

Abstract

The kinesin-microtubule system has emerged as a versatile model system for biologically-derived microscale transport. While kinesin motors in cells transport cargo along static microtubule tracks, for in vitro transport applications it is preferable to invert the system and transport cargo-functionalized microtubules along immobilized kinesin motors. However, for efficient cargo transport and to enable this novel transport system to be interfaced with traditional microfluidics, it is important to fabricate enclosed microchannels that are compatible with kinesin motors and microtubules, that enable fluorescence imaging of microtubule movement, and that provide fluidic connections for sample introduction. Here we construct a three-tier hierarchical system of microfluidic channels that links microscale transport channels to macroscopic fluid connections. Shallow microchannels (5 microm wide and 1 microm deep) are etched in a glass substrate and bonded to a cover glass using PMMA as an adhesive, while intermediate channels (approximately 100 microm wide) serve as reservoirs and connect to 250 microm deep microchannels that hold fine gauge tubing for fluid injection. To demonstrate the utility of this device, we first show the performance of a directional rectifier that redirects 96% of moving microtubules and, because any microtubules that detach rapidly rebind to the motor-coated surface, suffers no microtubule loss over time. Second, we develop an approach, using a headless kinesin construct, to eliminate gradients in motor adsorption and microtubule binding in the enclosed channels, which enables precise control of kinesin density in the microchannels. Finally, we show that a 60 microm diameter circular ring functionalized with motors concentrates and aligns bundles of approximately 3000 uniformly oriented microtubules, while suffering negligible ATP depletion. These aligned isopolar microtubules are an important tool for microscale transport applications and can be employed as a model in vitro system for studying kinesin-driven microtubule organization in cells.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17195111     DOI: 10.1007/s10544-006-9019-1

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  3 in total

1.  High-performance microfluidic rectifier based on sudden expansion channel with embedded block structure.

Authors:  Chien-Hsiung Tsai; Che-Hsin Lin; Lung-Ming Fu; Hui-Chun Chen
Journal:  Biomicrofluidics       Date:  2012-04-13       Impact factor: 2.800

2.  Surface-bound casein modulates the adsorption and activity of kinesin on SiO2 surfaces.

Authors:  Tomomitsu Ozeki; Vivek Verma; Maruti Uppalapati; Yukiko Suzuki; Mikihiko Nakamura; Jeffrey M Catchmark; William O Hancock
Journal:  Biophys J       Date:  2009-04-22       Impact factor: 4.033

3.  Transportation of nanoscale cargoes by myosin propelled actin filaments.

Authors:  Malin Persson; Maria Gullberg; Conny Tolf; A Michael Lindberg; Alf Månsson; Armagan Kocer
Journal:  PLoS One       Date:  2013-02-21       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.