Literature DB >> 22642261

Ten years later. Results from a prospective single-centre clinical study on 121 oxidized (TiUnite™) Brånemark implants in 46 patients.

Pär-Olov Östman1, Mats Hellman, Lars Sennerby.   

Abstract

BACKGROUND: Concerns have been raised that use of surface-modified implants may result in peri-implant infection and marked marginal bone loss over time.
PURPOSE: The aim of this prospective study was to evaluate the survival rate, marginal bone, and soft tissue conditions at surface-modified titanium dental implants after 10 years of function.
MATERIAL AND METHODS: Forty-six totally and partially edentulous patients were provided with 121 Brånemark oxidized implants (TiUnite™, Nobel Biocare AB, Gothenburg, Sweden). Twenty-four (20%) implants were immediate loaded and 97 (80%) were placed using a two-stage procedure. A total of 22 single, 23 partial, and 7 total restorations were delivered. Clinical and radiographic checkups were carried out after 3, 6, 12 months, and thereafter annually up to 10 years. At these occasions, oral hygiene was evaluated and peri-implant mucosa examined by probing. If needed, patients were enrolled in an individual program for hygiene controls and professional cleaning. Marginal bone loss was evaluated in intraoral radiographs taken at baseline and after 1, 5, and 10 years of function.
RESULTS: One (0.8%) implant failed after 8 years giving a Survival Rate (SR) of 99.2% after 10 years. A total of 11 sites (9.2%) showed bleeding on probing (BP) at the 10th annual checkup. The mean marginal bone loss was 0.7 ± 1.35 mm based on 106 readable pairs of radiographs from baseline and from the 10th annual examination. Twelve (11.3%) implants showed more than 2 mm bone loss, and five (4.7%) showed more than 3 mm of bone loss after 10 years. For the latter, all patients were smokers and had poor or acceptable oral hygiene. All five implants with >3 mm bone loss showed BP and two (1.9%) showed suppuration from the pocket. For the remaining seven implants with more than 2 mm bone loss, no correlation to smoking, oral hygiene, bleeding, or pus could be seen. Time/marginal bone level plots of the 12 implants with more than 2 mm bone loss after 10 years, showed minor changes from the first annual checkup except for the two infected implants.
CONCLUSIONS: It is concluded that good long-term clinical outcomes can be obtained with oxidized titanium dental implants. Only 1.9% of examined implants showed significant marginal bone loss together with bleeding and suppuration after 10 years of function.
© 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22642261     DOI: 10.1111/j.1708-8208.2012.00453.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  21 in total

Review 1.  Efficacy of autologous stem cells for bone regeneration during endosseous dental implants insertion - A systematic review of human studies.

Authors:  Shailesh Varshney; Anshuman Dwivedi; Vibha Pandey
Journal:  J Oral Biol Craniofac Res       Date:  2020-07-03

Review 2.  How frequent does peri-implantitis occur? A systematic review and meta-analysis.

Authors:  Mia Rakic; Pablo Galindo-Moreno; Alberto Monje; Sandro Radovanovic; Hom-Lay Wang; David Cochran; Anton Sculean; Luigi Canullo
Journal:  Clin Oral Investig       Date:  2017-12-07       Impact factor: 3.573

3.  Spark anodization of titanium-zirconium alloy: surface characterization and bioactivity assessment.

Authors:  Ajay Sharma; A James McQuillan; Lavanya A Sharma; John Neil Waddell; Yo Shibata; Warwick John Duncan
Journal:  J Mater Sci Mater Med       Date:  2015-08-11       Impact factor: 3.896

4.  Prevalence of Peri-Implant Mucositis and Peri-Implantitis in Patients Treated with a Combination of Axial and Tilted Implants Supporting a Complete Fixed Denture.

Authors:  Nicolò Cavalli; Stefano Corbella; Silvio Taschieri; Luca Francetti
Journal:  ScientificWorldJournal       Date:  2015-05-06

5.  A randomized, 12-month controlled trial to evaluate non-inferiority of early compared to conventional loading of modSLA implants in single tooth gaps.

Authors:  Michel Dard; Makoto Shiota; Minoru Sanda; Yasutomo Yajima; Hideshi Sekine; Shohei Kasugai
Journal:  Int J Implant Dent       Date:  2016-04-04

6.  Immediate Function of Anodically Oxidized Surface Implants (TiUnite™) for Fixed Prosthetic Rehabilitation: Retrospective Study with 10 Years of Follow-Up.

Authors:  Paulo Maló; Miguel de Araújo Nobre; Yolande Gonçalves; Armando Lopes; Ana Ferro
Journal:  Biomed Res Int       Date:  2016-12-29       Impact factor: 3.411

7.  Mucositis, peri-implantitis, and survival and success rates of oxide-coated implants in patients treated for periodontitis 3- to 6-year results of a case-series study.

Authors:  Reiner Mengel; Theresa Heim; Miriam Thöne-Mühling
Journal:  Int J Implant Dent       Date:  2017-11-28

8.  Multivariate analysis of the influence of peri-implant clinical parameters and local factors on radiographic bone loss in the posterior maxilla: a retrospective study on 277 dental implants.

Authors:  Mariane B Sordi; Vittoria Perrotti; Flavia Iaculli; Keila C R Pereira; Ricardo S Magini; Stefan Renvert; Stefano Antonio Gattone; Adriano Piattelli; Marco A Bianchini
Journal:  Clin Oral Investig       Date:  2020-11-05       Impact factor: 3.573

9.  Clinical and Radiographic Evaluation of Brånemark Implants with an Anodized Surface following Seven-to-Eight Years of Functional Loading.

Authors:  David Gelb; Bradley McAllister; Pirkka Nummikoski; Massimo Del Fabbro
Journal:  Int J Dent       Date:  2013-03-07

10.  Five-year retrospective radiographic follow-up study of dental implants with sandblasting with large grit, and acid etching-treated surfaces.

Authors:  Hak-Kyun Kim; Eun-Young Lee; Jae-Jin Kim
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2015-12-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.