Literature DB >> 29181639

Mucositis, peri-implantitis, and survival and success rates of oxide-coated implants in patients treated for periodontitis 3- to 6-year results of a case-series study.

Reiner Mengel1, Theresa Heim2, Miriam Thöne-Mühling3.   

Abstract

AIM: The aim of this case-series study is to evaluate the prevalence of mucositis, peri-implantitis, and survival and success rates of oxide-coated implants in subjects treated for periodontitis.
MATERIALS AND METHODS: Twenty-four subjects treated for generalized chronic periodontitis (GCP) and five treated for generalized aggressive periodontitis (GAP) were orally rehabilitated with a total of 130 dental implants. Subjects were examined 2 to 4 weeks prior to extraction of non-retainable teeth and at insertion of superstructure. Additional examinations were performed during a 3-month recall schedule over a 3- to 6-year follow-up period. Radiographs were taken after insertion of the superstructure and 1, 3, and 5 years later.
RESULTS: The results showed implant survival rates of 97.1% in GCP subjects versus 96.2% in GAP subjects. The implant success rate was 77.9% in GCP subjects and 38.5% in GAP subjects. In GCP subjects, mucositis was present in 7.7% and peri-implantitis in 12.5% of the implants. In GAP subjects, 28.0% of the implants showed mucositis and 32.0% peri-implantitis. Implant failure, mucositis, and peri-implantitis were more evident in GAP subjects. Peri-implantitis was more prevalent for implants in the maxilla and implants >10 mm. After 5 years, the mean peri-implant bone loss in GAP subjects was 2.89 mm and in GCP subjects 1.38 mm.
CONCLUSIONS: Periodontally diseased subjects treated in a supportive periodontal therapy can be successfully rehabilitated with oxide-coated dental implants for a follow-up period of 3- to 6-years. Implants in the maxilla and GAP subjects were more susceptible to mucositis and peri-implantitis, with lower implant survival and success rates.

Entities:  

Keywords:  Dental implants; Mucositis; Peri-implantitis; Periodontitis; Survival rate

Year:  2017        PMID: 29181639      PMCID: PMC5704031          DOI: 10.1186/s40729-017-0110-6

Source DB:  PubMed          Journal:  Int J Implant Dent        ISSN: 2198-4034


Background

In recent years, a great number of different implant systems varying in materials, surface structure, and macroscopic design have been introduced to the dental market [1]. In studies using implants with modified surfaces, it was concluded that rough surfaces induce a stronger initial bone response, achieve stability more rapidly, and integrate more fully with extant bone [2-6]. Dental implants with oxide-coated (anodised) surfaces have demonstrated, in histologic and histomorphometric examinations, that the newly formed bone infiltrates the pores of the surface oxide layer and thereby establishes a strong interlock between the bone and oxidized implant [7-9]. The oxide-coated implant surface is categorized as “moderately rough,” typically with a thickened titanium oxide layer of high crystallinity and phosphorous content. A prospective long-term clinical study on implants with oxide-coated surfaces revealed an implant survival rate of 99.2% and mean marginal bone loss of 0.7 ± 1.35 mm after 10 years of function [10]. Only 1.9% of the implants showed significant marginal bone loss (> 3 mm) together with bleeding on probing and suppuration. In a retrospective study, no difference could be found when comparing the clinical performance (survival rate, marginal bone loss, presence of bleeding, and probing depth) of turned versus oxide-coated surface implants after 5 years of loading [11]. In a 9-year study with an immediate loading protocol, implants with oxide-coated surfaces achieved a 10% higher survival rate compared to turned surface implants [12]. These results indicate that the survival rate of dental implants in long-term studies seems to be high, irrespective of surface type. However, the influence of the implant surface type on the development and progression of mucositis and peri-implantitis especially in periodontally diseased subjects remains largely unknown. In animal studies, it has been suggested that oxide-coated implants are more susceptible to mucositis and peri-implantitis [13-15]. Whether or to what extent these findings might be translated to humans is yet unknown. A Cochrane review found no evidence of a superior long-term success that could be attributed to any one type of implant surface [1]. Furthermore, the review concluded that there are limited data suggesting that implants with relatively smooth surfaces are less susceptible to peri-implantitis-induced bone loss. The aim of this long-term clinical study on partially edentulous subjects treated for periodontal disease was to evaluate the prevalence of mucositis and peri-implantitis and to determine the survival and success rates of dental implants with oxide-coated surfaces.

Materials and methods

Study population

A total of 29 partially edentulous subjects were consecutively recruited from the Dental School of Medicine, Philipps-University, Marburg, Germany between April 2010 and April 2013 (Table 1). Subjects were excluded for the following reasons: history of systemic disease (e.g., cardiovascular diseases, diabetes mellitus, osteoporosis), pregnancy, untreated caries, current orthodontic treatment, continuous drug administration, and psychiatric disorders. Systemic diseases were assessed by an internist.
Table 1

Implants in study population

GCPGAP
Patient245
Sex
 Female153
 Male92
Age
 < 50 years22
 > 50 years223
Implant system
 Nobelspeedy Replace RP4917
 Nobelspeedy Replace NP164
 Nobel Replace Straight Groovy295
 Nobelspeedy Groovy100
Topography
 Anterior maxilla2612
 Posterior maxilla3610
 Anterior mandible180
 Posterior mandible244
Superstructure
 Single crowns524
 Removable4121
 Fixed bridges110
Bone quality
 13
 29721
 345
Degree of atrophy
 A4112
 B2814
 C35
Implants in study population All subjects were treated for periodontitis at the Dental School of Medicine, Philipps-University, Marburg, Germany. Periodontal treatment was followed by a 3-month recall schedule for 3 to 6 years. Each recall session comprised oral hygiene control with motivation and instruction, subgingival scaling, and root planing at tooth surfaces with probing depth (PDs) > 4 mm, and bleeding on probing (BOP). Preceding implant placement, non-retainable teeth were removed and subgingival scaling and root planing were performed for residual teeth where necessary. Six months after tooth removal, the residual teeth showed healthy periodontal tissue with PDs ≤ 3 mm and no BOP. Periodontal disease was diagnosed according to the criteria of the American Academy of Periodontology [16]. The clinical and radiological findings in the recall schedule before insertion of the implants were the basis to distinguish between generalized chronic periodontitis (GCP) and generalized aggressive periodontitis (GAP). Twenty-four subjects (9 males and 15 females; mean age, 63 years) with GCP displaying more than 30% of sites affected, with bone loss < 0.2 mm per year. Five subjects (two males and three females; mean age, 31 years) with GAP displaying more than 30% of sites affected, with bone loss > 0.2 mm per year.

Implant placement and prosthesis

At total, 130 implants with oxide-coated surfaces (Nobel Replace Straight Groovy; Nobel Speedy Groovy; Nobel Speedy Replace, Nobel Biocare, Zürich, Switzerland) were placed with a length of 10 to 15 mm and a diameter of 3.5 or 4 mm. In GCP subjects 104 implants were inserted, and in GAP subjects, 26 implants (Table 1). In both groups, the bone quality and atrophy of the alveolar bone were classified during implant insertion according to Lekholm and Zarb [17]. Second-stage surgery was performed in the maxilla after 6 months and in the mandible after 3 months. Implant placement and second-stage surgery were performed by a single periodontist (R.M.). About 4 weeks after the final abutments were placed, GCP subjects were rehabilitated with single crowns, implant-supported bridges, or removable superstructures, according to the Marburg double crown system [18] (Table 1). In GAP subjects, single crowns or removable superstructures (Marburg double crown system) were inserted. All prosthetic appliances were provided at the Dental School of Medicine, Philipps-University, Marburg, Germany. All crowns and bridges were cemented and solely porcelain-fused-to-metal restorations.

Clinical parameters

At each session, the Gingival Index (GI) [19], Plaque Index (PI) [20], PDs, BOP, gingival recession (GR), and clinical attachment level (CAL) were evaluated at four sites (mesial, distal, buccal, and lingual/palatinal) on the teeth and implants. The CAL was measured at the teeth from the cement-enamel junction to the base of the pocket. For implants, the upper edge of the corresponding final abutment served as the top reference point. Trauma to peri-implant tissue was avoided by waiting 1 year after implant placement before measuring probing depths. The clinical examinations were performed by four examiners (all dentists, formally affiliated with the Dental School of Medicine, Philipps-University, Marburg, Germany) before study initiation, each examiner was calibrated for intra- and interexaminer reproducibility using duplicate measurements of a minimum of 50 sites in at least five subjects. The correlation coefficients were 0.90 to 0.99 for intraexaminer reproducibility and 0.91 to 0.95 for interexaminer reproducibility.

Radiographic examination

Standardized radiographs of the teeth and implants were taken by two persons using the parallel technique [21]. These radiographs were obtained immediately after insertion of the superstructure (baseline for mucositis and peri-implantitis evaluation) and at 1, 3, and 5 years thereafter. The digitized radiographs were evaluated using a computer software (Planmeca Romexis Version 3.0.1, Planmeca, Helsinki, Finland). Bone loss was determined in relative terms at the mesial and distal tooth surfaces by measuring the distance from the CEJ to the apex. The distance from the marginal bone level to the upper edge of the implant was measured (in mm) at the mesial and distal implant surfaces and related to the implant thread. All radiographs were analyzed by an independent masked examiner.

Study follow-up schedule

All patients received a supportive periodontal therapy at the Dental School of Medicine, Philipps-University, Marburg, in the course of the observation period. The first clinical examination was 2 to 4 weeks before the non-retainable teeth were extracted. The periodontally healthy residual dentition and the implants were evaluated immediately after the superstructure was inserted. Subsequently, the subjects were followed up at 3-month intervals for 3 to 6 years. At each follow-up session, the clinical parameters were recorded and subjects were remotivated and reinstructed in effective oral hygiene. In addition, the teeth and implants were cleaned professionally. Supragingival deposits were removed, followed by polishing with rubber cups and polishing paste. Subgingival debridement was performed in the teeth and implants with PDs > 4 mm and BOP positive. In the teeth, conventional stainless-steel curettes and ultrasonic devices were used, whereas in implants, plastic curettes and polyether ether ketone-tips for the ultrasonic device were applied to avoid damage of the implant surface. A functional analysis and medical history were performed at the beginning of the study and reviewed annually. Cigarette smoking status was self-reported. Subjects were considered smokers if they had been smoking 10 or more cigarettes a day during the past 5 years [22].

Statistical evaluations

Data analysis was performed with a computerized statistics package (SPSS 12.0.1 for Windows, SPSS). The examined patients were not included in any other publications. Mean values for clinical and radiologic parameters were determined separately for the implants and the teeth, for both patient groups, and for every visit. Four visits were consolidated for analysis. The probability of implant loss (implant survival) at a certain time was computed with reference to previously established criteria using a Kaplan-Meier survival curve. The assessment of implant success, mucositis, and peri-implantitis was performed at the time of radiographic examination 1 year after insertion of the superstructure and 3 and 5 years thereafter. The implant success rate was defined by the following parameters: no implant movement, no discomfort (pain, foreign body sensation etc.), PDs ≤ 5 mm without BOP, no continuous radiologic translucency surrounding implants, and annual peri-implant bone loss ≤ 0.2 mm 1 year after insertion of the superstructure [23]. Implants that did not meet at least one criterion were considered a failure. Peri-implant mucositis was defined as PDs ≥ 5 mm with BOP and no bone loss after the first year of loading. Peri-implantitis was defined as PDs > 5 mm with or without BOP and an annual bone loss of > 0.2 mm after the first year of loading. All technical and surgical complications (e.g., fracture of the abutment screw or superstructure, compromised wound healing) were recorded. The potential risk factors of gender, implant topography, implant length, type of superstructure, and bone quality and atrophy were analyzed for their correlation with the prevalence of mucositis, peri-implantitis, implant success, and survival. At first, the effect of each risk factor was tested with a univariate regression analysis. A multivariate analysis was performed for risk factors with P values of ≤ 0.05 in the univariate analysis. The extent of the effect of a risk factor was indicated with an odds ratio (OR), with a confidence interval (CI) of 95%.

Results

All 29 subjects were examined over the period of 3 to 6 years (Table 2). For the duration of the observation period, all the remaining teeth were periodontally healthy, with PDs ≤ 3 mm and negative BOP. All subjects were non-smokers, had excellent oral hygiene, attended the follow-up examinations on a regular basis, and had no systemic disease.
Table 2

Observation period (patient and implant related)

YearsPatients (total)GCP patientsGAP patientsImplants (total)Implants maxillaImplants mandible
TotalGCPGAPTotalGCPGAP
32924513084622246424
4221759255342137334
5201558453322131274
6171257450282124204
Observation period (patient and implant related)

Implant survival

In total, four implants (3.1%) were lost during the observation period. In a GAP subject (male), one implant (left upper first bicuspid) was removed during second-stage surgery because of mobility. In two GCP subjects (one male and one female), two implants with single crowns (right upper first bicuspid and left lower first molar) were removed after 53 and 68 months due to peri-implantitis. One implant with a single crown (right lower first molar) of a GCP subject (female) fractured 27 months after loading. The implant survival rate was 96.2% in GAP subjects and 97.1% in GCP subjects.

Mucositis

Nine subjects (31.0%) showed mucositis in 15 implants (11.6%) (Table 3). Three GAP subjects displayed mucositis in seven implants (28.0%), compared to eight implants (7.7%) in six GCP subjects. In more than 70% of the implants, a mucositis was first diagnosed after 3 years of loading.
Table 3

Risk factors for mucositis

Mucositis n Univariate analysesMultivariate analyses
OR(95% CI) P OR(95% CI) P
Subjects
 GAP354.500(0.601; 3.708)0.138n.s.
 GCP624
 Female7182.864(0.473; 17.351)0.231n.s.
 Male211
Implants
 GAP7254.667(1.504; 4.482)0.0104.672(1.447; 15.080)0.012
 GCP8104
 Female13765.269(1.135; 4.393)0.0135.267(1.104; 25.122)0.016
 Male253
Superstructure
 Single crown6560.897(0.509; 1.583)0.708n.s.
 Fixed bridge111
 Removable862
Bone quality
 1032.769(0.506; 15.168)0.203n.s.
 213118
 328
Degree of atrophy
 A8531.609(0.785; 3.298)0.179n.s.
 B541
 C235
Topography
 Ant. maxilla7382.423(0.647; 9.074)0.161n.s.
 Post. maxilla545
 Ant. mandible018
 Post. mandible328
Implant length
 ≥ 10 mm9810.875(0.291; 2.631)0.813n.s.
 < 10 mm648

Logistic regression analyses showed whether differences were significant (p ≤ 0.05)

CI confidence interval, n.s. non-significant, OR odds ratio, p significance

Risk factors for mucositis Logistic regression analyses showed whether differences were significant (p ≤ 0.05) CI confidence interval, n.s. non-significant, OR odds ratio, p significance In the multivariate implant-related analyses, the risk of mucositis was higher in GAP subjects (OR = 4.672 with p = 0.012) and in females (OR = 5.267 with p = 0.016). The uni- and multivariate patient-related analyses did not show significant differences. All other clinical parameters were found to be non-significant in both the implant- and patient-related analyses.

Peri-implantitis

Seven subjects (24.1%) with 21 implants (16.3%) showed peri-implantitis (Table 4). Three GAP subjects displayed peri-implantitis in 8 implants (32.0%) compared to 13 implants (12.5%) in four GCP subjects. In about 60% of the implants, a peri-implantitis was first diagnosed after 3 years of loading.
Table 4

Risk factors for peri-implantitis

Peri-implantitis n Univariate analysesMultivariate analyses
OR(95% CI) P OR(95% CI) P
Subjects
 GAP357.500(0.931; 60.427)0.054n.s.
 GCP424
 Female4180.762(0.135; 4.301)0.759n.s.
 Male311
Implants
 GAP8253.294(1.186; 9.151)0.0272.596(0.720; 9.352)0.149
 GCP13104
 Female9760.459(0.178; 1.184)0.105n.s.
 Male1253
Superstructure
 Single crown7560.881(0.538; 1.442)0.613n.s.
 Fixed bridge411
 Removable1062
Bone quality
 10321.200(3.915; 114.798)0.00030.896(5.178; 0.868)0.056
 216118
 368
Degree of atrophy
 A5530.716(0.404; 1.269)0.252n.s.
 B1041
 C635
Topography
 Ant. maxilla93814.286(1.849; 110.358)0.00015.680(1.914; 128.455)0.001
 Post. maxilla1145
 Ant. mandible018
 Post. mandible128
Implant length
 ≥ 10 mm9817.048(1.563; 31.782)0.0029.555(1.900; 48.051)0.001
 < 10 mm648

Logistic regression analyses showed whether differences were significant (p ≤ 0.05)

CI confidence interval, n.s. non-significant, OR odds ratio, p significance

Risk factors for peri-implantitis Logistic regression analyses showed whether differences were significant (p ≤ 0.05) CI confidence interval, n.s. non-significant, OR odds ratio, p significance In the multivariate implant-related analyses, the risk of peri-implantitis was higher in the maxilla (OR = 15.680 with p = 0.001) and implants >10 mm (OR = 9.555 with p = 0.001). All other clinical parameters were found to be non-significant. The univariate analyses showed a significantly higher risk for peri-implantitis in GAP subjects (OR = 3.294 with p = 0.027) and at implants with bone quality grade 3 (OR = 21.200 with p = 0.000). However, these differences were not significant in multivariate analyses. Both the uni- and multivariate patient-related analyses were non-significant.

Implant success

The implant success rate was 77.9% for GCP implants and 38.5% for GAP implants. Twenty-two implants (21.2%) failed in 10 GCP subjects (41.7%), and 16 implants (61.5%) failed in (all) GAP subjects (100.0%). In the multivariate implant-related analyses, implants placed in the maxilla (OR = 3.241 with p = 0.022), and in GAP subjects (OR = 4.218 with p = 0.006), had a significantly higher risk of failure. The multivariate patient-related analyses showed a higher risk of implant failure in GAP subjects (OR = 3.032 with p = 0.004) (Table 5).
Table 5

Implant failure rates

Failure rate n Univariate analysesMultivariate analyses
OR(95% CI) P OR(95% CI) P
Subjects
 GAP552.400(1.495; 3.853)0.0063.0320.004
 GCP1024(1.131; 8.123)
 Female11180.364(0.077; 1.716)0.194n.s.
 Male411
Implants
 GAP16265.964(2.378; 14.959)0.0004.218(1.515; 1.746)0.006
 GCP22104
 Female23761.128(0.522; 2.439)0.758n.s.
 Male1554
Superstructure
 Single crown15560.952(0.854; 1.062)0.368n.s.
 Fixed bridge511
 Removable1862
Bone quality
 1034.172(3.038; 5.731)0.000n.s.
 230118
 399
Degree of atrophy
 A14530.912(0.330; 2.496)0.156n.s.
 B1742
 C835
Topography
 Ant. maxilla16385.306(1.901; 14.810)0.0003.241(1.105; 9.512)0.022
 Post. maxilla1746
 Ant. mandible018
 Post. mandible628
Implant length
 ≥ 10 mm9820.485(0.211; 1.115)0.080n.s.
 < 10 mm648

Logistic regression analyses showed whether differences were significant (p ≤ 0.05)

CI confidence interval, n.s. non-significant, OR odds ratio, p significance

Implant failure rates Logistic regression analyses showed whether differences were significant (p ≤ 0.05) CI confidence interval, n.s. non-significant, OR odds ratio, p significance

Radiological evaluation

The mean mesial and distal marginal bone loss after 5 years was 2.19 mm (SD 1.85) in both patient groups. Peri-implant bone loss in GAP subjects was 2.89 mm (SD 1.90) and that in GCP subjects 1.38 mm (SD 1.05).

Complications

Mechanical complications were observed in two implants in two GAP subjects and in six implants in five GCP subjects. One abutment screw fractured, as well as the veneers of four ceramic crowns, and three abutments loosened and unscrewed. Surgical complications were not seen.

Discussion

The present study examines the success rates of oxide-coated implants in subjects with treated periodontal disease. Several long-term clinical studies on periodontally healthy subjects have revealed survival rates of 97.1 to 99.2% for oxide-coated implants [10, 24, 25]. The results of the present study show a comparable implant survival rate (96.2% in GAP and 97.1% in GCP subjects) for subjects with treated periodontal disease. These findings confirm numerous studies indicating that implants with different surfaces in subjects with generalized chronic periodontitis have a survival rate of over 90% after 5 years [23, 26–31]. In a prospective study with GCP subjects, implants with rough surfaces showed a survival rate of 96.0% after an observation period of 11.6 years [32]. However, the implant survival rate for GAP subjects was 80.0%, after a follow-up period of 8.3 years. The lower survival rate of implants in patients with GAP was also present on implants with turned surfaces. In a prospective 5- to 16-year study, the survival rate was only 83.3% [23]. When reflecting the higher survival rate of implants in GAP subjects in the present study, one has to consider the small number of subjects in this group as well as the short follow up of 6 years. In a systematic review, comparing implant survival rates for GAP subjects in long-term studies, it was shown that survival rates ranged from 97.4 to 100% in studies with a follow-up period of < 5 years, falling to 83.3 to 96.0% for studies with longer observation periods [33]. Although implant survival rates given in different studies are comparable, analyzing mucositis and peri-implantitis prevalence is challenging. In the present study, GCP subjects showed mucositis in 7.7% and peri-implantitis in 12.5% of the implants. The GAP group displayed mucositis in 28.0% and peri-implantitis in 32.0% of the implants. A prospective 10-year study that examined GCP subjects with rough surface implants revealed a slightly higher peri-implantitis rate (28.6%) [31]. In a 3- to 16-year study, GAP subjects with turned surfaces implants displayed a higher mucositis (56.0%) and a comparable peri-implantitis rate (26.0%) [23]. These results from long-term clinical studies indicate that oxide-coated implants achieve equivalent survival rates and prevalence of mucositis and peri-implantitis when compared to implants with other surface characteristics. They support the assumption that the implant surface has little influence on the development of mucositis or peri-implantitis. This was subsequently confirmed in a Cochrane review, where in clinical long-term studies no evidence could be found that any specific type of implant system or surface modification conferred superior long-term success [1]. The findings of the present clinical study also allow us to put the previous results obtained from animal studies into context [13-15]. These studies analyzed the effects of ligature-induced peri-implantitis in implants with different surface characteristics placed in Labrador dogs. The results revealed increased marginal bone loss and more soft tissue destruction surrounding oxide-coated implants as compared to implants with other surfaces. These animal studies were subject to critical review [34], with the authors identifying shortcomings pertaining to the statistical analyses. Due to the small number of animals examined (six dogs), it is not possible to draw any valid conclusion regarding clinical application in human subjects. It is also apparent that the results of such animal studies are not wholly predictive of the human scenario [35].

Conclusions

The results of the present case series study should be interpreted in a critical light because of the small study population. However, it can be concluded that periodontally diseased subjects treated in a supportive periodontal therapy can be successfully rehabilitated with oxide-coated dental implants for a follow-up period of 3 to 6 years. The results suggest that implants in the maxilla and in subjects treated for generalized aggressive periodontitis were more susceptible to developing mucositis and peri-implantitis, with lower implant survival and success rates.
  33 in total

1.  PERIODONTAL DISEASE IN PREGNANCY. II. CORRELATION BETWEEN ORAL HYGIENE AND PERIODONTAL CONDTION.

Authors:  J SILNESS; H LOE
Journal:  Acta Odontol Scand       Date:  1964-02       Impact factor: 2.331

2.  A retrospective comparison of oxidized and turned implants with respect to implant survival, marginal bone level and peri-implant soft tissue conditions after at least 5 years in function.

Authors:  Måns Jungner; Peter Lundqvist; Stefan Lundgren
Journal:  Clin Implant Dent Relat Res       Date:  2012-06-21       Impact factor: 3.932

3.  Spontaneous progression of peri-implantitis at different types of implants. An experimental study in dogs. I: clinical and radiographic observations.

Authors:  Jean-Pierre Albouy; Ingemar Abrahamsson; Leif G Persson; Tord Berglundh
Journal:  Clin Oral Implants Res       Date:  2008-10       Impact factor: 5.977

4.  Comments on the letter from Kjell Pettersson and Reiner Mengel by the editorial team of EJOI.

Authors:  Marco Esposito; Michele Nieri; Jerome Lindeboom
Journal:  Eur J Oral Implantol       Date:  2011       Impact factor: 3.123

5.  Mucositis, peri-implantitis, implant success, and survival of implants in patients with treated generalized aggressive periodontitis: 3- to 16-year results of a prospective long-term cohort study.

Authors:  Katrin Swierkot; Peer Lottholz; Lavin Flores-de-Jacoby; Reiner Mengel
Journal:  J Periodontol       Date:  2012-01-20       Impact factor: 6.993

6.  The effect of smoking on mechanical and antimicrobial periodontal therapy.

Authors:  D F Kinane; M Radvar
Journal:  J Periodontol       Date:  1997-05       Impact factor: 6.993

7.  Biomechanical and histomorphometric study of dental implants with different surface characteristics.

Authors:  In-Sung Yeo; Jung-Suk Han; Jae-Ho Yang
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2008-11       Impact factor: 3.368

8.  A telescopic crown concept for the restoration of partially edentulous patients with aggressive generalized periodontitis: a 3-year prospective longitudinal study.

Authors:  Reiner Mengel; Gerd Kreuzer; Klaus M Lehmann; Lavin Flores-de-Jacoby
Journal:  Int J Periodontics Restorative Dent       Date:  2007-06       Impact factor: 1.840

9.  Outcomes of dental implant treatment in patients with generalized aggressive periodontitis: a systematic review.

Authors:  Kyoung-Kyu Kim; Hun-Mo Sung
Journal:  J Adv Prosthodont       Date:  2012-11-29       Impact factor: 1.904

10.  In vitro and in vivo studies of surface-structured implants for bone formation.

Authors:  Lu Xia; Bo Feng; Peizhi Wang; Siyang Ding; Zhiyuan Liu; Jie Zhou; Rong Yu
Journal:  Int J Nanomedicine       Date:  2012-09-11
View more
  1 in total

1.  Long-term follow-up of full-arch immediate implant-supported restorations in edentulous jaws: a clinical study.

Authors:  Laura Werbelow; Michael Weiss; Alexander Schramm
Journal:  Int J Implant Dent       Date:  2020-07-30
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.