Literature DB >> 22633017

Utilization of a lower extremity ambulatory feedback system to reduce gait asymmetry in transtibial amputation gait.

L Yang1, P S Dyer, R J Carson, J B Webster, K Bo Foreman, S J M Bamberg.   

Abstract

The goal of our research is to augment gait rehabilitation for persons with gait asymmetry through a real-time feedback system that can be used independently by patients in the community. Our wireless, wearable, real-time gait asymmetry detection system called the lower extremity ambulatory feedback system (LEAFS) is a low-cost, in-shoe gait detection device that provides real-time auditory feedback based on the stance time symmetry ratio between the right and left limbs. This study evaluated the performance of the LEAFS in three study subjects with gait asymmetry secondary to unilateral transtibial amputation. Study subjects used the LEAFS for six 30-min training sessions under the supervision of a physical therapist. Two subjects demonstrated improved gait symmetry, with one subject reducing trunk sway by 85.5%, and the other subject reducing trunk sway by 16.0% and increasing symmetry ratio toward unity by 26.5%, as measured by a clinical motion analysis lab. The third subject did not demonstrate any objective improvements in gait symmetry or trunk sway. While testing with a larger number of subjects is necessary, this initial study using LEAFS with persons with transtibial amputations suggests that it can assist in improving gait symmetry in this population.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22633017     DOI: 10.1016/j.gaitpost.2012.04.004

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  16 in total

1.  Effects of sensory augmentation on postural control and gait symmetry of transfemoral amputees: a case description.

Authors:  Anna Pagel; Alejandro Hernandez Arieta; Robert Riener; Heike Vallery
Journal:  Med Biol Eng Comput       Date:  2015-12-31       Impact factor: 2.602

2.  Gait Training Interventions for Lower Extremity Amputees: A Systematic Literature Review.

Authors:  M Jason Highsmith; Casey R Andrews; Claire Millman; Ashley Fuller; Jason T Kahle; Tyler D Klenow; Katherine L Lewis; Rachel C Bradley; John J Orriola
Journal:  Technol Innov       Date:  2016-09-01

3.  Error-Manipulation Gait Training for Veterans With Nontraumatic Lower Limb Amputation: A Randomized Controlled Trial Protocol.

Authors:  Paul W Kline; Noel So; Thomas Fields; Elizabeth Juarez-Colunga; Cory L Christiansen
Journal:  Phys Ther       Date:  2021-11-01

4.  Gait asymmetry is associated with performance-based physical function among adults with lower-limb amputation.

Authors:  Mayank Seth; Peter C Coyle; Ryan T Pohlig; Emma H Beisheim; John R Horne; Gregory E Hicks; Jaclyn Megan Sions
Journal:  Physiother Theory Pract       Date:  2021-10-17       Impact factor: 2.176

5.  Step length symmetry adaptation to split-belt treadmill walking after acquired non-traumatic transtibial amputation.

Authors:  Paul W Kline; Amanda M Murray; Matthew J Miller; Noel So; Thomas Fields; Cory L Christiansen
Journal:  Gait Posture       Date:  2020-05-31       Impact factor: 2.840

6.  Error-augmentation gait training to improve gait symmetry in patients with non-traumatic lower limb amputation: A proof-of-concept study.

Authors:  Paul W Kline; Amanda M Murray; Matthew J Miller; Thomas Fields; Cory L Christiansen
Journal:  Prosthet Orthot Int       Date:  2019-04-24       Impact factor: 1.895

Review 7.  Control strategies for active lower extremity prosthetics and orthotics: a review.

Authors:  Michael R Tucker; Jeremy Olivier; Anna Pagel; Hannes Bleuler; Mohamed Bouri; Olivier Lambercy; José Del R Millán; Robert Riener; Heike Vallery; Roger Gassert
Journal:  J Neuroeng Rehabil       Date:  2015-01-05       Impact factor: 4.262

8.  Combining Vibrotactile Feedback with Volitional Myoelectric Control for Robotic Transtibial Prostheses.

Authors:  Baojun Chen; Yanggang Feng; Qining Wang
Journal:  Front Neurorobot       Date:  2016-08-22       Impact factor: 2.650

9.  Evaluation of limb load asymmetry using two new mathematical models.

Authors:  Senthil N S Kumar; Baharudin Omar; Leonard H Joseph; Ohnmar Htwe; K Jagannathan; Nor M Y Hamdan; D Rajalakshmi
Journal:  Glob J Health Sci       Date:  2014-09-25

10.  Gait Training in Chronic Stroke Using Walk-Even Feedback Device: A Pilot Study.

Authors:  V Krishnan; I Khoo; P Marayong; K DeMars; J Cormack
Journal:  Neurosci J       Date:  2016-11-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.