Ceramic-on-ceramic bearings in hip arthroplasty: state of the art and the future.

J R T Jeffers1, W L Walter.   

Abstract

This systematic review of the literature summarises the clinical experience with ceramic-on-ceramic hip bearings over the past 40 years and discusses the concerns that exist in relation to the bearing combination. Loosening, fracture, liner chipping on insertion, liner canting and dissociation, edge-loading and squeaking have all been reported, and the relationship between these issues and implant design and surgical technique is investigated. New design concepts are introduced and analysed with respect to previous clinical experience.

Entities:  

Mesh:

Year:  2012        PMID: 22628586     DOI: 10.1302/0301-620X.94B6.28801

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  27 in total

1.  Squeaking: Current knowledge and how to avoid it.

Authors:  Arjuna M Imbuldeniya; Simon J Pearce; William L Walter; Bernard A Zicat; William K Walter
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

2.  Experience with sandwich liner and its high rate of failure.

Authors:  John Junghun Shin; Ji-Soo Shin; Jae-Hyun Kim; Sung Kwan Hwang
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-07-16

3.  Catastrophic ceramic liner failure-The subtle signs of a non-engaged ceramic liner.

Authors:  Andrew Walls; Adam Tucker; David S Warnock; David Beverland
Journal:  J Orthop       Date:  2018-02-20

4.  Ceramic bearings with bilayer coating in cementless total hip arthroplasty. A safe solution. A retrospective study of one hundred and twenty six cases with more than ten years' follow-up.

Authors:  André Ferreira; Thierry Aslanian; Thibaud Dalin; Jean Picaud
Journal:  Int Orthop       Date:  2016-08-20       Impact factor: 3.075

5.  Joint replacement surgery and the innate immune system.

Authors:  Stuart B Goodman; Yrjo T Konttinen; Michiaki Takagi
Journal:  J Long Term Eff Med Implants       Date:  2014

6.  Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA?

Authors:  Seung-Hoon Baek; Won Keun Kim; Jun Young Kim; Shin-Yoon Kim
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

7.  Navigated Acetabular Cup Fixation for Acetabular Deformity or Revision Total Hip Arthroplasty.

Authors:  Ho Hyun Yun; Jung-Ro Yoon; Jung Jin Yu; Hyo-Sung Seo
Journal:  Hip Pelvis       Date:  2014-09-29

8.  An adhesive bone marrow scaffold and bone morphogenetic-2 protein carrier for cartilage tissue engineering.

Authors:  Jacob A Simson; Iossif A Strehin; Qiaozhi Lu; Manuel O Uy; Jennifer H Elisseeff
Journal:  Biomacromolecules       Date:  2013-02-04       Impact factor: 6.988

9.  Can patients return to high-impact physical activities after hip resurfacing? A prospective study.

Authors:  Julien Girard; Bruno Miletic; Anthony Deny; Henri Migaud; Nicolas Fouilleron
Journal:  Int Orthop       Date:  2013-03-02       Impact factor: 3.075

Review 10.  Review on squeaking hips.

Authors:  Yadin David Levy; Selin Munir; Shane Donohoo; William Lindsay Walter
Journal:  World J Orthop       Date:  2015-11-18
View more