| Literature DB >> 22621614 |
Tormod Selbekk1, Reidar Brekken, Marit Indergaard, Ole Solheim, Geirmund Unsgård.
Abstract
BACKGROUND: Image contrast between normal tissue and brain tumours may sometimes appear to be low in intraoperative ultrasound. Ultrasound imaging of strain is an image modality that has been recently explored for intraoperative imaging of the brain. This study aims to investigate differences in image contrast between ultrasound brightness mode (B-mode) images and ultrasound strain magnitude images of brain tumours.Entities:
Mesh:
Year: 2012 PMID: 22621614 PMCID: PMC3468395 DOI: 10.1186/1471-2342-12-11
Source DB: PubMed Journal: BMC Med Imaging ISSN: 1471-2342 Impact factor: 1.930
Figure 1Ultrasound B-mode and strain images. The ultrasound B-mode image of a glioblastoma (grade IV) in (a) and the corresponding strain magnitude image (b). For display purposes the delineation of the solid tumour close to the location of the measurements is marked with a bright line in the B-mode image. The B-mode intensity plotted along the lateral direction at a user- selected depth is shown in (c), with the numbers of the x-axis referring to the distance [m] from the lateral midpoint of the image. The strain magnitudes are plotted in similar way and displayed in (d), with the Y-axis showing strain magnitude values from 0–8 ‰. The depth of the plotted magnitudes is for display purposes indicated with a bright arrow in (a) and (b). The values picked for estimation of contrast between tumour tissue and assumed normal tissue are indicated by black arrowheads in (c) and (d).
Strain and B-mode contrast
| low-grade glioma | 1 | 0.55 (0.11) | 0.43 (0.20) |
| | 2 | 0.56 (0.27) | 0.61 (0.20) |
| | 3 | 0.57 (0.08) | 0.27 (0.04) |
| | 4 | 0.58 (0.19) | 0.46 (0.13) |
| | 5 | 0.51 (0.04) | 0.32 (0.06) |
| | 6 | 0.64 (0.12) | 0.36 (0.07) |
| | 7 | 0.66 (0.25) | 0.35 (0.12) |
| | 8 | 0.84 (0.04) | 0.56 (0.11) |
| high-grade glioma | 9 | 0.58 (0.22) | 0.31 (0.06) |
| | 10 | 0.48 (0.21) | 0.24 (0.09) |
| | 11 | 0.58 (0.11) | 0.25 (0.19) |
| | 12 | 0.50 (0.07) | 0.29 (0.06) |
| | 13 | 0.69 (0.17) | 0.42 (0.08) |
| | 14 | 0.65 (0.17) | 0.60 (0.12) |
| | 15 | 0.60 (0.03) | 0.44 (0.24) |
| All data | 0.60 (0.16) | 0.39 (0.16) |
The average and standard deviation (σ) of the three contrast measurements obtained for each patient.
Figure 2Box plot of B-mode and strain contrast. Box plot of brightness mode and strain magnitude contrast for the low-grade glioma samples (a) and the high-grade glioma samples (b). The lower and upper edges of the box represent the first and third quartile respectively, while a horizontal line within the box indicates the median. The vertical length of the box represents the interquartile range (IQR). The most extreme sample values (within a distance of 1.5 IQR from the median) are the endpoints of the lines extending from the box. Possible outliers are shown as circles.