Literature DB >> 20040770

Sonoelastographic strain index for differentiation of benign and malignant nonpalpable breast masses.

Nariya Cho1, Woo Kyung Moon, Ha Young Kim, Jung Min Chang, Sang Hee Park, Chae Yeon Lyou.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate the diagnostic potential of the sonoelastographic strain index for differentiation of nonpalpable breast masses.
METHODS: Ninety-nine nonpalpable breast masses (79 benign and 20 malignant) in 94 women (mean age, 45 years; range, 21-68 years) who had been scheduled for a sonographically guided core biopsy were examined with B-mode sonography and sonoelastography. Radiologists who had performed the biopsies analyzed the B-mode sonograms and provided American College of Radiology Breast Imaging Reporting and Data System categories. The strain index (fat to lesion strain ratio) was calculated by dividing the strain value of the subcutaneous fat by that of the mass. The histologic result from the sonographically guided core biopsy was used as a reference standard. The diagnostic performance of the strain index and that of B-mode sonography were compared by receiver operating characteristic (ROC) curve analysis.
RESULTS: The mean strain index values +/- SD were 6.57 +/- 6.62 (range, 1.29-28.69) in malignant masses and 2.63 +/- 4.57 (range, 0.54-38.76) in benign masses (P = .019). The area under the ROC curve values were 0.835 (95% confidence interval [CI], 0.747-0.902) for B-mode sonography and 0.879 (95% CI, 0.798-0.936) for the strain index (P = .490). The sensitivity, specificity, positive predictive value, and negative predictive value were 95% (19 of 20), 75% (59 of 79), 48% (19 of 39), and 98% (59 of 60), respectively, when a best cutoff point of 2.24 was used.
CONCLUSIONS: The strain index based on the fat to lesion strain ratio has diagnostic performance comparable with that of B-mode sonography for differentiation of benign and malignant breast masses.

Entities:  

Mesh:

Year:  2010        PMID: 20040770     DOI: 10.7863/jum.2010.29.1.1

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  42 in total

1.  Harmonic Motion Imaging (HMI) for Tumor Imaging and Treatment Monitoring.

Authors:  Elisa E Konofagou; Caroline Maleke; Jonathan Vappou
Journal:  Curr Med Imaging Rev       Date:  2012

2.  Can strain elastography combined with ultrasound breast imaging reporting and data system be a more effective method in the differentiation of benign and malignant breast lesions?

Authors:  Serdar Arslan; Nihal Uslu; Funda Ulu Ozturk; Eda Yilmaz Akcay; Tugan Tezcaner; Ahmet Muhtesem Agildere
Journal:  J Med Ultrason (2001)       Date:  2017-02-02       Impact factor: 1.314

3.  Real-time tissue elastography assessment of skin and subcutaneous tissue strains in legs with lymphedema.

Authors:  Kotaro Suehiro; Kaori Nakamura; Noriyasu Morikage; Masanori Murakami; Osamu Yamashita; Koshiro Ueda; Makoto Samura; Kimikazu Hamano
Journal:  J Med Ultrason (2001)       Date:  2014-03-04       Impact factor: 1.314

4.  Ultrasonographic elastography of the breast using acoustic radiation force impulse technology: preliminary study.

Authors:  Mitsuhiro Tozaki; Sachiko Isobe; Miki Yamaguchi; Yukari Ogawa; Kanako Homma; Masahiro Saito; Chanwoong Joo; Eisuke Fukuma
Journal:  Jpn J Radiol       Date:  2011-07-24       Impact factor: 2.374

5.  Ultrasonographic tissue quantification of the breast using acoustic radiation force impulse technology: phantom study and clinical application.

Authors:  Mitsuhiro Tozaki; Masahiro Saito; Chanwoong Joo; Miki Yamaguchi; Sachiko Isobe; Yukari Ogawa; Kanako Homma; Eisuke Fukuma
Journal:  Jpn J Radiol       Date:  2011-09-17       Impact factor: 2.374

6.  Sonoelastography findings for idiopathic granulomatous mastitis.

Authors:  Afak Durur-Karakaya; Irmak Durur-Subasi; Mufide Nuran Akcay; Sare Sipal; Bülent Guvendi
Journal:  Jpn J Radiol       Date:  2014-12-03       Impact factor: 2.374

7.  Breast elastography: A literature review.

Authors:  A Goddi; M Bonardi; S Alessi
Journal:  J Ultrasound       Date:  2012-06-30

8.  Prospective evaluation in 123 patients of strain ratio as provided by quantitative elastosonography and multiparametric ultrasound evaluation (ultrasound score) for the characterisation of thyroid nodules.

Authors:  Vito Cantisani; Vito D'Andrea; Ester Mancuso; Elena Maggini; Mattia Di Segni; Matteo Olive; Pietro Lodise; Silvio Palermo; Sergio De Antoni; Adriano Redler; Gregorio Patrizi; Andrea Porfiri; Giovanna Panzironi; Paolo Ricci
Journal:  Radiol Med       Date:  2013-06-26       Impact factor: 3.469

9.  Effects of compression force on elasticity index and elasticity ratio in ultrasound elastography.

Authors:  A Imaizumi; Y Sasaki; J Sakamoto; T Kamio; K Nishikawa; M Otonari-Yamamoto; M Wako
Journal:  Dentomaxillofac Radiol       Date:  2014-02-07       Impact factor: 2.419

10.  Modeling Uncertainty of Strain Ratio Measurements in Ultrasound Breast Strain Elastography: A Factorial Experiment.

Authors:  David Rosen; Jingfeng Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-09-23       Impact factor: 2.725

View more