Literature DB >> 22619314

Cumulative radiation dose from medical imaging in kidney transplant patients.

Andreana De Mauri1, Marco Brambilla, Cristina Izzo, Roberta Matheoud, Doriana Chiarinotti, Alessandro Carriero, Piero Stratta, Martino De Leo.   

Abstract

BACKGROUND: Although many patients undergoing kidney transplant are exposed to multiple examinations that increase cumulative effective doses (CEDs) of ionizing radiation, no data are available characterizing their total longitudinal radiation burden and relating radiation burden with risk factors for more exposure.
METHODS: We did a retrospective cohort study of 92 patients (mean age 52 years; range: 20-75 years) who underwent kidney transplant at University Hospital, Novara, Italy, that evaluated all following medical imaging procedures involving ionizing radiation undergone beginning June 2007, and all subsequent procedures through August 2011, at the centre.
RESULTS: The mean and median annual CED were 17.2 and 4.9 millisieverts (mSv) per patient-year. The mean and median total CED per patient over the study period were 46.1 and 17.3 mSv, respectively. Twenty-eight and 12% of patients had total CED >50 and 100 mSv, values which are associated with a good or strong evidence of an increased cancer mortality risk, respectively. Computed tomography scanning accounted for 73% of the total CED. The annual CED was significantly higher in incident patients and in patients with ischaemic heart disease and cancer.
CONCLUSION: In this institution, multiple testing of kidney transplant patients was common in many patients associated with high cumulative estimated doses of ionizing radiation.

Entities:  

Mesh:

Year:  2012        PMID: 22619314     DOI: 10.1093/ndt/gfs145

Source DB:  PubMed          Journal:  Nephrol Dial Transplant        ISSN: 0931-0509            Impact factor:   5.992


  7 in total

1.  Radiation exposure from medical imaging in dialyzed patients undergoing renal pre-transplant evaluation.

Authors:  Andreana De Mauri; Roberta Matheoud; Alessandro Carriero; Domenico Lizio; Doriana Chiarinotti; Marco Brambilla
Journal:  J Nephrol       Date:  2016-03-02       Impact factor: 3.902

2.  Ionizing radiation exposure among kidney transplant recipients due to medical imaging during the pretransplant evaluation.

Authors:  Kim N Nguyen; Anup M Patel; Francis L Weng
Journal:  Clin J Am Soc Nephrol       Date:  2013-02-07       Impact factor: 8.237

Review 3.  Radiation risk issues in recurrent imaging.

Authors:  Charles Brower; Madan M Rehani
Journal:  Br J Radiol       Date:  2021-06-23       Impact factor: 3.629

4.  Radiation Exposure from Diagnostic Imaging in a Cohort of Pediatric Transplant Recipients.

Authors:  Alexandra Seal; Michael Hawkes; Ravi Bhargava; Michelle Noga; Jutta Preiksaitis; Curtis Mabilangan; Joan Robinson
Journal:  PLoS One       Date:  2017-01-12       Impact factor: 3.240

5.  Tables for effective dose assessment from diagnostic radiology (period 1946-1995) in epidemiologic studies.

Authors:  Merle Friederike Meiboom; Wolfgang Hoffmann; Kerstin Weitmann; Heiner von Boetticher
Journal:  PLoS One       Date:  2021-04-01       Impact factor: 3.240

6.  Multinational data on cumulative radiation exposure of patients from recurrent radiological procedures: call for action.

Authors:  Marco Brambilla; Jenia Vassileva; Agnieszka Kuchcinska; Madan M Rehani
Journal:  Eur Radiol       Date:  2019-12-02       Impact factor: 5.315

Review 7.  Radiation protection perspective to recurrent medical imaging: what is known and what more is needed?

Authors:  Jenia Vassileva; Ola Holmberg
Journal:  Br J Radiol       Date:  2021-06-23       Impact factor: 3.629

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.