Monte Carlo simulated correction factors for machine specific reference field dose calibration and output factor measurement using fixed and iris collimators on the CyberKnife system.

P Francescon1, W Kilby, N Satariano, S Cora.   

Abstract

Monte Carlo (MC) simulation of dose to water and dose to detector has been used to calculate the correction factors needed for dose calibration and output factor measurements on the CyberKnife system. Reference field ionization chambers simulated were the PTW 30006, Exradin A12, and NE 2571 Farmer chambers, and small volume chambers PTW 31014 and 31010. Correction factors for Farmer chambers were found to be 0.7%-0.9% larger than those determined from TRS-398 due mainly to the dose gradient across the chamber cavity. For one microchamber where comparison was possible, the factor was 0.5% lower than TRS-398 which is consistent with previous MC simulations of flattening filter free Linacs. Output factor detectors simulated were diode models PTW 60008, 60012, 60017, 60018, Sun Nuclear edge detector, air-filled microchambers Exradin A16 and PTW 31014, and liquid-filled microchamber PTW 31018 microLion. Factors were generated for both fixed and iris collimators. The resulting correction factors differ from unity by up to +11% for air-filled microchambers and -6% for diodes at the smallest field size (5 mm), and tend towards unity with increasing field size (correction factor magnitude <1% for all detectors at field sizes >15 mm). Output factor measurements performed using these detectors with fixed and iris collimators on two different CyberKnife systems showed initial differences between detectors of >15% at 5 mm field size. After correction the measurements on each unit agreed within ∼1.5% at the smallest field size. This paper provides a complete set of correction factors needed to apply a new small field dosimetry formalism to both collimator types on the CyberKnife system using a range of commonly used detectors.

Entities:  

Mesh:

Year:  2012        PMID: 22617842     DOI: 10.1088/0031-9155/57/12/3741

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Evaluation of a synthetic single-crystal diamond detector for relative dosimetry measurements on a CyberKnife.

Authors:  A Chalkley; G Heyes
Journal:  Br J Radiol       Date:  2014-03       Impact factor: 3.039

Review 2.  Stereotactic radiosurgery alone for multiple brain metastases? A review of clinical and technical issues.

Authors:  Arjun Sahgal; Mark Ruschin; Lijun Ma; Wilko Verbakel; David Larson; Paul D Brown
Journal:  Neuro Oncol       Date:  2017-04-01       Impact factor: 12.300

3.  Comparative analysis between 5 mm and 7.5 mm collimators in CyberKnife radiosurgery for trigeminal neuralgia.

Authors:  H Sudahar; P G G Kurup; V Murali; J Velmurugan
Journal:  J Med Phys       Date:  2013-07

4.  Feasibility of using glass-bead thermoluminescent dosimeters for radiotherapy treatment plan verification.

Authors:  Shakardokht M Jafari; Tom J Jordan; Gail Distefano; David A Bradley; Nicholas M Spyrou; Andrew Nisbet; Catharine H Clark
Journal:  Br J Radiol       Date:  2015-08-10       Impact factor: 3.039

5.  Variation of kQclin,Qmsr (fclin,fmsr) for the small-field dosimetric parameters percentage depth dose, tissue-maximum ratio, and off-axis ratio.

Authors:  Paolo Francescon; Sam Beddar; Ninfa Satariano; Indra J Das
Journal:  Med Phys       Date:  2014-10       Impact factor: 4.071

6.  Measurement of percentage dose at the surface for a 6 MV photon beam.

Authors:  O O Galván De la Cruz; M A Rodríguez-Ávila; T Rivera-Montalvo; O A García Garduño
Journal:  Rep Pract Oncol Radiother       Date:  2019-10-18

7.  Tumor-dose-rate variations during robotic radiosurgery of oligo and multiple brain metastases.

Authors:  Maria-Lisa Wilhelm; Mark K H Chan; Benedikt Abel; Florian Cremers; Frank-Andre Siebert; Stefan Wurster; David Krug; Robert Wolff; Jürgen Dunst; Guido Hildebrandt; Achim Schweikard; Dirk Rades; Floris Ernst; Oliver Blanck
Journal:  Strahlenther Onkol       Date:  2020-06-25       Impact factor: 3.621

8.  Small field detector correction factors: effects of the flattening filter for Elekta and Varian linear accelerators.

Authors:  Madelaine K Tyler; Paul Z Y Liu; Christopher Lee; David R McKenzie; Natalka Suchowerska
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

9.  Characterization of a new commercial single crystal diamond detector for photon- and proton-beam dosimetry.

Authors:  Yuichi Akino; Archana Gautam; Len Coutinho; Jan Würfel; Indra J Das
Journal:  J Radiat Res       Date:  2015-08-12       Impact factor: 2.724

10.  Characterization of recombination effects in a liquid ionization chamber used for the dosimetry of a radiosurgical accelerator.

Authors:  Antoine Wagner; Frederik Crop; Thomas Lacornerie; Nick Reynaert
Journal:  J Vis Exp       Date:  2014-05-09       Impact factor: 1.355

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.