Literature DB >> 22612130

Temperature-modulated fluorescence tomography based on both concentration and lifetime contrast.

Yuting Lin1, Tiffany C Kwong, Linden Bolisay, Gultekin Gulsen.   

Abstract

It is challenging to image fluorescence objects with high spatial resolution in a highly scattering medium. Recently reported temperature-sensitive indocyanine green-loaded pluronic nanocapsules can potentially alleviate this problem. Here we demonstrate a frequency-domain temperature-modulated fluorescence tomography system that could acquire images at high intensity-focused ultrasound resolution with use of these nanocapsules. The system is experimentally verified with a phantom study, where a 3-mm fluorescence object embedded 2 cm deep in a turbid medium is successfully recovered based on both intensity and lifetime contrast.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22612130      PMCID: PMC3381013          DOI: 10.1117/1.JBO.17.5.056007

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  23 in total

1.  Fluorescence-enhanced optical imaging in large tissue volumes using a gain-modulated ICCD camera.

Authors:  Anuradha Godavarty; Margaret J Eppstein; Chaoyang Zhang; Sangeeta Theru; Alan B Thompson; Michael Gurfinkel; Eva M Sevick-Muraca
Journal:  Phys Med Biol       Date:  2003-06-21       Impact factor: 3.609

Review 2.  In vivo near-infrared fluorescence imaging.

Authors:  John V Frangioni
Journal:  Curr Opin Chem Biol       Date:  2003-10       Impact factor: 8.822

3.  Ultrasound-modulated fluorescence from rhodamine B aqueous solution.

Authors:  Baohong Yuan; Yuan Liu
Journal:  J Biomed Opt       Date:  2010 Mar-Apr       Impact factor: 3.170

4.  Near infrared dyes as lifetime solvatochromic probes for micropolarity measurements of biological systems.

Authors:  Mikhail Y Berezin; Hyeran Lee; Walter Akers; Samuel Achilefu
Journal:  Biophys J       Date:  2007-06-15       Impact factor: 4.033

5.  A time domain fluorescence tomography system for small animal imaging.

Authors:  Anand T N Kumar; Scott B Raymond; Andrew K Dunn; Brian J Bacskai; David A Boas
Journal:  IEEE Trans Med Imaging       Date:  2008-08       Impact factor: 10.048

6.  Multispectral optoacoustic tomography (MSOT) scanner for whole-body small animal imaging.

Authors:  Rui Ma; Adrian Taruttis; Vasilis Ntziachristos; Daniel Razansky
Journal:  Opt Express       Date:  2009-11-23       Impact factor: 3.894

7.  Time-dependent whole-body fluorescence tomography of probe bio-distributions in mice.

Authors:  Sachin Patwardhan; Sharon Bloch; Samuel Achilefu; Joseph Culver
Journal:  Opt Express       Date:  2005-04-04       Impact factor: 3.894

8.  Fluorescence lifetime spectroscopy of a pH-sensitive dye encapsulated in hydrogel beads.

Authors:  Eddy Kuwana; Feng Liang; Eva M Sevick-Muraca
Journal:  Biotechnol Prog       Date:  2004 Sep-Oct

9.  Pluronic F127-g-poly(acrylic acid) copolymers as in situ gelling vehicle for ophthalmic drug delivery system.

Authors:  Wen-Di Ma; Hui Xu; Chao Wang; Shu-Fang Nie; Wei-San Pan
Journal:  Int J Pharm       Date:  2007-09-07       Impact factor: 5.875

Review 10.  Pre-clinical whole-body fluorescence imaging: Review of instruments, methods and applications.

Authors:  Frederic Leblond; Scott C Davis; Pablo A Valdés; Brian W Pogue
Journal:  J Photochem Photobiol B       Date:  2009-11-26       Impact factor: 6.252

View more
  18 in total

1.  Implementation of a new scanning method for high-resolution fluorescence tomography using thermo-sensitive fluorescent agents.

Authors:  Farouk Nouizi; Tiffany C Kwong; Jaedu Cho; Yuting Lin; Uma Sampathkumaran; Gultekin Gulsen
Journal:  Opt Lett       Date:  2015-11-01       Impact factor: 3.776

2.  High-resolution imaging in a deep turbid medium based on an ultrasound-switchable fluorescence technique.

Authors:  Baohong Yuan; Seiichi Uchiyama; Yuan Liu; Kytai T Nguyen; George Alexandrakis
Journal:  Appl Phys Lett       Date:  2012-07-17       Impact factor: 3.791

3.  Experimental evaluation of the resolution and quantitative accuracy of temperature-modulated fluorescence tomography.

Authors:  Tiffany C Kwong; Farouk Nouizi; Yuting Lin; Jaedu Cho; Yue Zhu; Uma Sampathkumaran; Gultekin Gulsen
Journal:  Appl Opt       Date:  2017-01-20       Impact factor: 1.980

4.  A thermo-sensitive fluorescent agent based method for excitation light leakage rejection for fluorescence molecular tomography.

Authors:  Farouk Nouizi; Tiffany C Kwong; Jessica Ruiz; Jaedu Cho; Yu-Wen Chan; Kenji Ikemura; Hakan Erkol; Uma Sampathkumaran; Gultekin Gulsen
Journal:  Phys Med Biol       Date:  2019-01-22       Impact factor: 3.609

5.  Breaking the acoustic diffraction limit via nonlinear effect and thermal confinement for potential deep-tissue high-resolution imaging.

Authors:  Baohong Yuan; Yanbo Pei; Jayanth Kandukuri
Journal:  Appl Phys Lett       Date:  2013-02-14       Impact factor: 3.791

6.  Feasibility study of high spatial resolution multimodality fluorescence tomography in ex vivo biological tissue.

Authors:  Tiffany C Kwong; Farouk Nouizi; Jaedu Cho; Yuting Lin; Uma Sampathkumaran; Gultekin Gulsen
Journal:  Appl Opt       Date:  2017-10-01       Impact factor: 1.980

7.  Development of Ultrasound-switchable Fluorescence Imaging Contrast Agents based on Thermosensitive Polymers and Nanoparticles.

Authors:  Bingbing Cheng; Ming-Yuan Wei; Yuan Liu; Harish Pitta; Zhiwei Xie; Yi Hong; Kytai T Nguyen; Baohong Yuan
Journal:  IEEE J Sel Top Quantum Electron       Date:  2014 May-Jun       Impact factor: 4.544

8.  Development of ultrasound-assisted fluorescence imaging of indocyanine green.

Authors:  Hiroyasu Morikawa; Shin Toyota; Kenji Wada; Sawako Uchida-Kobayashi; Norifumi Kawada; Hiromichi Horinaka
Journal:  J Med Ultrason (2001)       Date:  2016-08-26       Impact factor: 1.314

9.  Simulation-based evaluation of the resolution and quantitative accuracy of temperature-modulated fluorescence tomography.

Authors:  Yuting Lin; Farouk Nouizi; Tiffany C Kwong; Gultekin Gulsen
Journal:  Appl Opt       Date:  2015-09-01       Impact factor: 1.980

10.  Improving sensitivity and imaging depth of ultrasound-switchable fluorescence via an EMCCD-gain-controlled system and a liposome-based contrast agent.

Authors:  Tingfeng Yao; Yang Liu; Liqin Ren; Baohong Yuan
Journal:  Quant Imaging Med Surg       Date:  2021-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.