Literature DB >> 22611340

Quadrature RF Coil for In Vivo Brain MRI of a Macaque Monkey in a Stereotaxic Head Frame.

Colin A Roopnariane1, Yeun-Chul Ryu, Mohammad-Reza Tofighi, Patti A Miller, Sukhoon Oh, Jianli Wang, Bu Sik Park, Lukas Ansel, Christopher A Lieu, Thyagarajan Subramanian, Qing X Yang, Christopher M Collins.   

Abstract

We present a quadrature volume coil designed for brain imaging of a macaque monkey fixed in a sphinx position (facing down the bore) within a stereotactic frame at 3 T, where the position of the monkey and presence of the frame preclude use of existing coils. Requirements include the ability to position and remove the coil without disturbing the position of the monkey in the frame. A saddle coil and a solenoid were combined on a modified cylindrical former and connected in quadrature as to produce a homogeneous circularly polarized field throughout the brain. To allow the loops of the saddle coil to encompass the ear posts, partial disassembly and reassembly were facilitated by embedding pin and socket contacts into separate pieces of the former. Coil design included simulation of the electromagnetic fields for the coil containing a 3D model of a monkey's head. The resulting coil produced adequate homogeneity and signal-to-noise ratio throughout the brain.

Entities:  

Year:  2012        PMID: 22611340      PMCID: PMC3354963          DOI: 10.1002/cmr.b.21205

Source DB:  PubMed          Journal:  Concepts Magn Reson Part B Magn Reson Eng        ISSN: 1552-5031            Impact factor:   1.176


  6 in total

1.  Anesthetic protocol: propofol use in Rhesus macaques (Macaca mulatta) during magnetic resonance imaging with stereotactic head frame application.

Authors:  K A Fowler; M J Huerkamp; J K Pullium; T Subramanian
Journal:  Brain Res Brain Res Protoc       Date:  2001-06

2.  Magnetic resonance imaging of the rhesus monkey brain: use for stereotactic neurosurgery.

Authors:  R C Saunders; T G Aigner; J A Frank
Journal:  Exp Brain Res       Date:  1990       Impact factor: 1.972

3.  MRI guidance improves accuracy of stereotaxic targeting for cell transplantation in parkinsonian monkeys.

Authors:  Thyagarajan Subramanian; Milind Deogaonkar; Marijn Brummer; Roy Bakay
Journal:  Exp Neurol       Date:  2005-05       Impact factor: 5.330

4.  A non-invasive, relocatable stereotactic frame for fractionated radiotherapy and multiple imaging.

Authors:  J D Graham; A P Warrington; S S Gill; M Brada
Journal:  Radiother Oncol       Date:  1991-05       Impact factor: 6.280

5.  Method of construction of a MRI-based tabular database of 3D stereotaxic co-ordinates for individual structures in the basal ganglia of Macaca mulatta.

Authors:  Milind Deogaonkar; Marcel Heers; Supriya Mahajan; Marijn Brummer; Thyagarajan Subramanian
Journal:  J Neurosci Methods       Date:  2005-08-03       Impact factor: 2.390

6.  A 4-channel 3 Tesla phased array receive coil for awake rhesus monkey fMRI and diffusion MRI experiments.

Authors:  Mark Haig Khachaturian
Journal:  J Biomed Sci Eng       Date:  2010-01-01
  6 in total