A non-invasive, relocatable stereotactic frame for fractionated radiotherapy and multiple imaging.

J D Graham1, A P Warrington, S S Gill, M Brada.   

Abstract

A non-invasive relocatable stereotactic frame has been developed for fractionated stereotactic external beam radiotherapy (SRT) by linear accelerator. Fixation is via the upper dentition and tests of repositioning have shown mean antero-posterior and lateral displacements of 1.0 mm. The relocatable frame allows accurate 3-dimensional target localisation by CT, MRI, PET and cerebral angiography and precise isocentric positioning for radiotherapy. This method of immobilisation is ideal for fractionated SRT as well as for other techniques requiring high precision localisation and treatment delivery.

Mesh:

Year:  1991        PMID: 1852920     DOI: 10.1016/0167-8140(91)90342-e

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  8 in total

1.  Quadrature RF Coil for In Vivo Brain MRI of a Macaque Monkey in a Stereotaxic Head Frame.

Authors:  Colin A Roopnariane; Yeun-Chul Ryu; Mohammad-Reza Tofighi; Patti A Miller; Sukhoon Oh; Jianli Wang; Bu Sik Park; Lukas Ansel; Christopher A Lieu; Thyagarajan Subramanian; Qing X Yang; Christopher M Collins
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2012-02-18       Impact factor: 1.176

Review 2.  Recent trends in the radiotherapy of pediatric gliomas.

Authors:  N J Tarbell; J S Loeffler
Journal:  J Neurooncol       Date:  1996 May-Jun       Impact factor: 4.130

3.  Preliminary Evaluation of a Novel Thermoplastic Mask System with Intra-fraction Motion Monitoring for Future Use with Image-Guided Gamma Knife.

Authors:  Winnie Li; Gregory Bootsma; Oscar Von Schultz; Per Carlsson; Normand Laperriere; Barbara-Ann Millar; David Jaffray; Caroline Chung
Journal:  Cureus       Date:  2016-03-13

4.  Analysis of patient repositioning accuracy in precision radiation therapy using automated image fusion.

Authors:  James L Robar; Brenda G Clark; Jason W Schella; Chang Seon Kim
Journal:  J Appl Clin Med Phys       Date:  2005-01-12       Impact factor: 2.102

5.  To frame or not to frame? Cone-beam CT-based analysis of head immobilization devices specific to linac-based stereotactic radiosurgery and radiotherapy.

Authors:  Steven Babic; Young Lee; Mark Ruschin; Fiona Lochray; Alex Lightstone; Eshetu Atenafu; Nic Phan; Todd Mainprize; May Tsao; Hany Soliman; Arjun Sahgal
Journal:  J Appl Clin Med Phys       Date:  2018-01-24       Impact factor: 2.102

6.  Fractionated stereotactic radiotherapy for skull base tumors: analysis of treatment accuracy using a stereotactic mask fixation system.

Authors:  Giuseppe Minniti; Maurizio Valeriani; Enrico Clarke; Marco D'Arienzo; Michelangelo Ciotti; Roberto Montagnoli; Francesca Saporetti; Riccardo Maurizi Enrici
Journal:  Radiat Oncol       Date:  2010-01-13       Impact factor: 3.481

7.  Towards a noninvasive intracranial tumor irradiation using 3d optical imaging and multimodal data registration.

Authors:  R Posada; Ch Daul; D Wolf; P Aletti
Journal:  Int J Biomed Imaging       Date:  2007

8.  Importance of CBCT setup verification for optical-guided frameless radiosurgery.

Authors:  Lei Fu; Harold Perera; Xiao Ying; Yan Yu
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102