Surgical glove bacterial contamination and perforation during total hip arthroplasty implantation: when gloves should be changed.

J Beldame1, B Lagrave, L Lievain, B Lefebvre, N Frebourg, F Dujardin.   

Abstract

INTRODUCTION: Double gloving is recommended in orthopedic surgery, notably in total hip arthroplasties (THA) to prevent contamination of the surgical site. HYPOTHESIS: Systematic glove changes during the key phases of hip prosthesis implantation reduce the frequency of occult perforations and bacterial loading of glove surfaces. PATIENTS AND METHODS: During 29 THA implantation procedures, we evaluated the bacterial contamination of the outer glove surface and its perforation rate. Contaminations were sought by placing the gloved fingertips on blood geloses (incubation, 48 h at 37°C), and perforations were sought using a water test (NF EN 455-1).
RESULTS: One intervention was excluded from the study because an initial contamination was detected, leaving 28 cases analyzed. Fifteen interventions (53.6%) presented contaminated geloses (26 contaminated glove changes for 3.38% of the gloves used). These contaminations were found on the gloves of all of the gloved personnel, with no distinction as to the right or left side. Thirty-eight percent of the contaminations occurred during joint reduction, whereas the other surgical stages grouped 15-26% of the contaminations (P<0.05). Twenty-nine bacteria were identified: 62% coagulase-negative staphylococci (16% of which were methicillin-resistant). Twenty-eight perforations were identified (3.5% of the gloves used), 67.8% of which were located on the operator and 64.3% on the dominant side. Eighty percent of the perforations occurred during the "surgical incision" and the "cup and stem implantation" stages (respectively, 5.0% and 5.5% of the gloves used during the surgical time) (P<0.05), without being associated with an increased risk of bacterial contamination. At the 12-month clinical follow-up, no infectious complications were found. On the gloves worn by the 20 surgical team members contaminated during these 28 surgical procedures, replacing contaminated gloves with new sterile gloves rendered all the bacteriological samples of the subsequent surgical stages negative in 16 cases (80%). DISCUSSION: Increasing the number of outer glove renewals, notably during certain surgical stages at risk for contamination (prosthesis reduction) or perforation (surgical incision/femoral cementing) can reduce the risk of contamination and perforation. The bacteria isolated suggest a cutaneous origin. Regularly changing gloves has resulted in a sterile state in 80% of cases. LEVEL OF EVIDENCE AND TYPE OF STUDY: Level III prospective diagnostic study.
Copyright © 2012 Elsevier Masson SAS. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22578871     DOI: 10.1016/j.otsr.2011.10.015

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  20 in total

1.  Bacterial contamination of gloves worn by small animal surgeons in a veterinary teaching hospital.

Authors:  Meagan Walker; Ameet Singh; Joyce Rousseau; J Scott Weese
Journal:  Can Vet J       Date:  2014-12       Impact factor: 1.008

2.  Predicting surgical site infections following laparoscopic bariatric surgery: development of the BariWound tool using the MBSAQIP database.

Authors:  Jerry T Dang; Caroline Tran; Noah Switzer; Megan Delisle; Michael Laffin; Karen Madsen; Daniel W Birch; Shahzeer Karmali
Journal:  Surg Endosc       Date:  2019-06-24       Impact factor: 4.584

3.  A prospective study on the risk of glove fingertip contamination during draping in joint replacement surgery.

Authors:  D Makki; K Deierl; A Pandit; S Trakru
Journal:  Ann R Coll Surg Engl       Date:  2014-09       Impact factor: 1.891

Review 4.  Prevention of fracture-related infection: a multidisciplinary care package.

Authors:  Willem-Jan Metsemakers; Jolien Onsea; Emilie Neutjens; Ester Steffens; Annette Schuermans; Martin McNally; Stefaan Nijs
Journal:  Int Orthop       Date:  2017-08-22       Impact factor: 3.075

5.  INTRAOPERATIVE EVALUATION AND LEVEL OF CONTAMINATION DURING TOTAL KNEE ARTHROPLASTY.

Authors:  Abdulaziz Z Alomar; Saud M Alfayez; Ahmad Binnasser; Fawzi F Aljassir
Journal:  Acta Ortop Bras       Date:  2022-07-06       Impact factor: 0.683

6.  Method of intraoperative tissue sampling for culture has an effect on contamination risk.

Authors:  Antonia F Chen; Meredith Menz; Priscilla K Cavanaugh; Javad Parvizi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-09-12       Impact factor: 4.342

7.  High Risk of Surgical Glove Perforation From Surgical Rotatory Instruments.

Authors:  Ashton H Goldman; Emanuel Haug; John R Owen; Jennifer S Wayne; Gregory J Golladay
Journal:  Clin Orthop Relat Res       Date:  2016-06-23       Impact factor: 4.176

8.  Fluid collection bags pose a threat for bacterial contamination in primary total hip arthroplasty: a prospective, internally controlled, non-blinded trial.

Authors:  M M Ploeger; C Jacobs; M Gathen; E Kaup; T M Randau; M J Friedrich; G T Hischebeth; M D Wimmer
Journal:  Arch Orthop Trauma Surg       Date:  2018-06-11       Impact factor: 3.067

Review 9.  Does the type of surgical drape (disposable versus non-disposable) affect the risk of subsequent surgical site infection?

Authors:  David C Kieser; Michael C Wyatt; Andrew Beswick; Setor Kunutsor; Gary J Hooper
Journal:  J Orthop       Date:  2018-05-07

Review 10.  Prevention of Periprosthetic Joint Infection.

Authors:  Alisina Shahi; Javad Parvizi
Journal:  Arch Bone Jt Surg       Date:  2015-04