Literature DB >> 17946555

Angiographic assessment of the performance of flow divertors to treat cerebral aneurysms.

Chander Sadasivan1, Baruch B Lieber, Liliana Cesar, Laszlo Miskolczi, Jaehoon Seong, Ajay K Wakhloo.   

Abstract

Past clinical and experimental evidence suggests that cerebral aneurysms can be successfully excluded from the circulation solely by the endovascular placement of a flow diverting device across the aneurysm neck. These devices promote intraaneurysmal flow stasis and concomitant thrombosis by redirecting flow away from the aneurysm. To comprehensively test the efficacy of such flow divertors, we are implanting devices with three different porosities in a large cohort of elastase-induced aneurysms in rabbits. Treatment efficacy is quantified by a mathematical model that is fit to aneurysmal angiographic contrast washout curves. Results from three animals implanted with different device porosities are presented here. The model competently captures the behavior of the aneurysmal washout curves and provides reliable indices of device efficacy. Preliminary analysis indicates that immediately after implantation, the device with medium porosity performs better than the devices with lower and higher porosities.

Entities:  

Mesh:

Year:  2006        PMID: 17946555     DOI: 10.1109/IEMBS.2006.260043

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  9 in total

Review 1.  From bench to bedside: utility of the rabbit elastase aneurysm model in preclinical studies of intracranial aneurysm treatment.

Authors:  Waleed Brinjikji; Yong H Ding; David F Kallmes; Ramanathan Kadirvel
Journal:  J Neurointerv Surg       Date:  2015-04-22       Impact factor: 5.836

2.  In vitro angiographic comparison of the flow-diversion performance of five neurovascular stents.

Authors:  Ronak J Dholakia; Ari D Kappel; Andrew Pagano; Henry H Woo; Baruch B Lieber; David J Fiorella; Chander Sadasivan
Journal:  Interv Neuroradiol       Date:  2017-12-14       Impact factor: 1.610

3.  Angiographic CT with intravenous contrast agent application for monitoring of intracranial flow diverting stents.

Authors:  Marc Saake; Tobias Struffert; Philipp Goelitz; Sabine Ott; Frank Seifert; Oliver Ganslandt; Arnd Doerfler
Journal:  Neuroradiology       Date:  2011-10-04       Impact factor: 2.804

4.  Effects of metal coverage rate of flow diversion device on neointimal growth at side branch ostium and stented artery: an animal experiment in rabbit abdominal aorta.

Authors:  Bo Hong; Kuizhong Wang; Qinghai Huang; Yi Xu; Xinggen Fang; Zhen Li; Jianmin Liu
Journal:  Neuroradiology       Date:  2011-12-15       Impact factor: 2.804

5.  Cellular mechanisms of aneurysm occlusion after treatment with a flow diverter.

Authors:  Ramanathan Kadirvel; Yong-Hong Ding; Daying Dai; Issa Rezek; Debra A Lewis; David F Kallmes
Journal:  Radiology       Date:  2013-10-28       Impact factor: 11.105

6.  Early angiographic changes of intra-aneurysmal flow after flow-diverter stent treatment are not predictive of therapeutic success.

Authors:  Paul-Emile Labeyrie; Benjamin Gory; Udi Sadeh-Gonike; Nazyed Huguet; Rotem Sivan-Hoffmann; Roberto Riva; Patrick Courthéoux; Francis Turjman
Journal:  Interv Neuroradiol       Date:  2016-08-10       Impact factor: 1.610

7.  Treatment of rabbit elastase-induced aneurysm models by flow diverters: development of quantifiable indexes of device performance using digital subtraction angiography.

Authors:  Chander Sadasivan; Liliana Cesar; Jaehoon Seong; Ajay K Wakhloo; Baruch B Lieber
Journal:  IEEE Trans Med Imaging       Date:  2009-01-19       Impact factor: 10.048

8.  Analysis of intra-aneurysmal flow for cerebral aneurysms with cerebral angiography.

Authors:  L-D Jou; M E Mawad
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-10       Impact factor: 3.825

9.  Pipeline embolization device for giant internal carotid artery aneurysms: 9-month follow-up results of two cases.

Authors:  Hong-Jun Jeon; Dong-Joon Kim; Byung-Moon Kim; Jae-Whan Lee
Journal:  J Cerebrovasc Endovasc Neurosurg       Date:  2014-06-30
  9 in total