Literature DB >> 22569955

Italian multicenter experience with flow-diverter devices for intracranial unruptured aneurysm treatment with periprocedural complications--a retrospective data analysis.

Francesco Briganti1, Manuela Napoli, Fabio Tortora, Domenico Solari, Mauro Bergui, Edoardo Boccardi, Enrico Cagliari, Lucio Castellan, Francesco Causin, Elisa Ciceri, Luigi Cirillo, Roberto De Blasi, Luigi Delehaye, Francesco Di Paola, Andrea Fontana, Roberto Gasparotti, Giulio Guidetti, Ignazio Divenuto, Giuseppe Iannucci, Maurizio Isalberti, Marco Leonardi, Fernando Lupo, Salvatore Mangiafico, Andrea Manto, Roberto Menozzi, Mario Muto, Nunzio Paolo Nuzzi, Rosario Papa, Benedetto Petralia, Mariangela Piano, Maurizio Resta, Riccardo Padolecchia, Andrea Saletti, Giovanni Sirabella, Luca Piero Valvassori Bolgè.   

Abstract

INTRODUCTION: We report the experiences of 25 Italian centers, analyzing intra- and periprocedural complications of endovascular treatment of intracranial aneurysms using Silk (Balt Extrusion, Montmorency, France) and pipeline embolization devices (EV3 Inc, Irvine California).
METHODS: Two hundred seventy-three patients with 295 cerebral aneurysms, enrolled in 25 centers in Italy and treated with the new flow-diverter devices, were evaluated; 142 patients were treated with Silk and 130 with pipeline (in one case, both devices were used). In 14 (5.2 %) cases devices were used with coils. Aneurysm size was >15 mm in 46.9 %, 5-15 mm in 42.2 %, and <5 mm in 10.8 %. Aneurysm locations were supraclinoid internal carotid artery (ICA) in 163 cases (55.2 %), cavernous ICA in 76 (25.7 %), middle cerebral artery in 11 (3.7 %), PCoA in 6 (2 %), and ACoA in 2 (0.7 %); the vertebrobasilar system accounted for 32 cases (10.8 %) and PCA in 5 (1.7 %).
RESULTS: Technical adverse events occurred with 59 patients (21.6 %); 5 patients died after ischemic events, 10 to hemorrhagic complications, and 1 from external ventricular drain positioning. At 1 month, morbidity and mortality rates were 3.7 % and 5.9 %, respectively
CONCLUSION: Our retrospective study confirms that morbidity and mortality rates in treatment with FDD of unruptured wide-neck or untreatable cerebral aneurysms do not differ from those reported in the largest series.

Entities:  

Mesh:

Year:  2012        PMID: 22569955     DOI: 10.1007/s00234-012-1047-3

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  29 in total

1.  Vascular reconstruction of a fusiform basilar aneurysm with the Silk embolization system.

Authors:  J M Pumar; R Garcia-Dorrego; A Nieto; F Vazquez-Herrero; M Blanco-Ulla; A Vazquez-Martin
Journal:  J Neurointerv Surg       Date:  2010-06-25       Impact factor: 5.836

2.  Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment.

Authors:  Z Kulcsár; E Houdart; A Bonafé; G Parker; J Millar; A J P Goddard; S Renowden; G Gál; B Turowski; K Mitchell; F Gray; M Rodriguez; R van den Berg; A Gruber; H Desal; I Wanke; D A Rüfenacht
Journal:  AJNR Am J Neuroradiol       Date:  2010-11-11       Impact factor: 3.825

3.  The pipeline embolization device for the intracranial treatment of aneurysms trial.

Authors:  P K Nelson; P Lylyk; I Szikora; S G Wetzel; I Wanke; D Fiorella
Journal:  AJNR Am J Neuroradiol       Date:  2010-12-09       Impact factor: 3.825

4.  Treatment of intracranial aneurysms by functional reconstruction of the parent artery: the Budapest experience with the pipeline embolization device.

Authors:  I Szikora; Z Berentei; Z Kulcsar; M Marosfoi; Z S Vajda; W Lee; A Berez; P K Nelson
Journal:  AJNR Am J Neuroradiol       Date:  2010-02-11       Impact factor: 3.825

5.  Reconstruction of the right anterior circulation with the Pipeline embolization device to achieve treatment of a progressively symptomatic, large carotid aneurysm.

Authors:  D Fiorella; F Albuquerque; F Gonzalez; C G McDougall; P K Nelson
Journal:  J Neurointerv Surg       Date:  2009-09-16       Impact factor: 5.836

Review 6.  Advances in interventional neuroradiology.

Authors:  Ajay K Wakhloo; Michael J Deleo; Martin M Brown
Journal:  Stroke       Date:  2009-05       Impact factor: 7.914

7.  Predictors of rehemorrhage after treatment of ruptured intracranial aneurysms: the Cerebral Aneurysm Rerupture After Treatment (CARAT) study.

Authors:  S Claiborne Johnston; Christopher F Dowd; Randall T Higashida; Michael T Lawton; Gary R Duckwiler; Daryl R Gress
Journal:  Stroke       Date:  2007-11-29       Impact factor: 7.914

8.  Endovascular occlusion of intracranial wide-necked aneurysms with stenting (Neuroform) and coiling: mid-term and long-term results.

Authors:  Jacques Sedat; Yves Chau; Lydiane Mondot; Julian Vargas; Jacek Szapiro; Michel Lonjon
Journal:  Neuroradiology       Date:  2009-02-25       Impact factor: 2.804

9.  International subarachnoid aneurysm trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion.

Authors:  Andrew J Molyneux; Richard S C Kerr; Ly-Mee Yu; Mike Clarke; Mary Sneade; Julia A Yarnold; Peter Sandercock
Journal:  Lancet       Date:  2005 Sep 3-9       Impact factor: 79.321

10.  Retreatment of ruptured cerebral aneurysms in patients randomized by coiling or clipping in the International Subarachnoid Aneurysm Trial (ISAT).

Authors:  Adriana Campi; Najib Ramzi; Andrew J Molyneux; Paul E Summers; Richard S C Kerr; Mary Sneade; Julia A Yarnold; Joan Rischmiller; James V Byrne
Journal:  Stroke       Date:  2007-03-29       Impact factor: 7.914

View more
  61 in total

Review 1.  Flow-diverter devices in the treatment of intracranial aneurysms: A meta-analysis and systematic review.

Authors:  Xianli Lv; Hongchao Yang; Peng Liu; Youxiang Li
Journal:  Neuroradiol J       Date:  2016-02-02

Review 2.  Endovascular treatment of cerebral aneurysms using flow-diverter devices: A systematic review.

Authors:  Francesco Briganti; Giuseppe Leone; Mariano Marseglia; Giuseppe Mariniello; Ferdinando Caranci; Arturo Brunetti; Francesco Maiuri
Journal:  Neuroradiol J       Date:  2015-08-27

3.  Initial Experience with p64: A Novel Mechanically Detachable Flow Diverter for the Treatment of Intracranial Saccular Sidewall Aneurysms.

Authors:  S Fischer; M Aguilar-Pérez; E Henkes; W Kurre; O Ganslandt; H Bäzner; H Henkes
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-13       Impact factor: 3.825

Review 4.  Emerging Technologies in Flow Diverters and Stents for Cerebrovascular Diseases.

Authors:  Michael Karsy; Jian Guan; Andrea A Brock; Anubhav Amin; Min S Park
Journal:  Curr Neurol Neurosci Rep       Date:  2017-10-28       Impact factor: 5.081

5.  Periprocedural safety of Pipeline therapy for unruptured cerebral aneurysms: Analysis of 279 Patients in a multihospital database.

Authors:  Robert J McDonald; Jennifer S McDonald; David F Kallmes; Giuseppe Lanzino; Harry J Cloft
Journal:  Interv Neuroradiol       Date:  2015-02       Impact factor: 1.610

6.  Flow-diverter stenting of post-traumatic bilateral anterior cerebral artery pseudoaneurysm: A case report.

Authors:  Andrea Giorgianni; Carlo Pellegrino; Renzo Minotto; Anna Mercuri; Lara Frattini; Fabio Baruzzi; Luca Valvassori
Journal:  Interv Neuroradiol       Date:  2015-02       Impact factor: 1.610

7.  Flow Diversion for Intracranial Aneurysm Management: A New Standard of Care.

Authors:  Fawaz Al-Mufti; Krishna Amuluru; Chirag D Gandhi; Charles J Prestigiacomo
Journal:  Neurotherapeutics       Date:  2016-07       Impact factor: 7.620

8.  Silk flow-diverter stent for the treatment of complex intracranial aneurysms: A one-year follow-up multicenter study.

Authors:  G Foa Torres; F Roca; A Noguera; J Godes; S Petrocelli; I Aznar; S Ales; P Muszynski; R Maehara; M Vicente; J M Pumar
Journal:  Interv Neuroradiol       Date:  2018-05-02       Impact factor: 1.610

Review 9.  [Management of paraophthalmic aneurysms : Review of endovascular treatment strategies].

Authors:  P Bhogal; M Aguilar Pérez; G Sauder; H Bäzner; O Ganslandt; H Henkes
Journal:  Ophthalmologe       Date:  2018-02       Impact factor: 1.059

10.  Treatment of complex intracranial aneurysms using flow-diverting silk® stents. An analysis of 32 consecutive patients.

Authors:  Ramazan Buyukkaya; Hasan Kocaeli; Nalan Yildirim; Hakan Cebeci; Cüneyt Erdogan; Bahattin Hakyemez
Journal:  Interv Neuroradiol       Date:  2014-12-05       Impact factor: 1.610

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.