Rectal transection using a curved cutter stapler with an endo-Satinsky clamp during a laparoscopic low anterior resection.

Tsukasa Hotta1, Katsunari Takifuji, Shozo Yokoyama, Kenji Matsuda, Hiroki Yamaue.   

Abstract

PURPOSE: A new rectal transaction method was developed using a combination of the curved cutter stapler and endo-Satinsky clamp because of the difficulty in performing rectal transection in the narrow pelvic cavity.
METHODS: The endo-Satinsky clamp is inserted without a flexible trocar cannula by connecting the handle extra-abdominally with a shaft of the endo-Satinsky clamp through the left higher quadrant port via a retrograde course from a midline incision above the pubis symphysis. The endo-Satinsky clamp is used to clamp the rectal wall horizontally at the distal end of the tumor. The wrist of an elastic surgical glove fixed with the shaft of the curved cutter stapler is covered with a midline incision, and consequently, the stapler is inserted into the pelvic cavity. The curved head of the stapler is rotated to the left at the anal side of the endo-Satinsky clamp to insert the rectum between the jaws of the stapler. The stapler is closed and fired, and a rectal transection is thus performed with one firing using a single cartridge.
RESULTS: This method was performed in 12 patients with rectal cancer. The median value and range of the tumor distance from the anal verge were 7.0 and 4.5-11.0 cm, respectively. The median duration of the operation was 252 min, and the median blood loss was 15 mL. Only one stapling cartridge was used for rectal transection in all cases, and no major complications were observed.
CONCLUSIONS: We herein demonstrated a new transection method for rectal cancer.

Entities:  

Mesh:

Year:  2012        PMID: 22552609     DOI: 10.1007/s00423-012-0955-3

Source DB:  PubMed          Journal:  Langenbecks Arch Surg        ISSN: 1435-2443            Impact factor:   3.445


  8 in total

1.  The application of a new stapling device for open surgery (Contour Curved Cutter Stapler) in the laparoscopic resection of rectal cancer.

Authors:  Y Ishii; H Hasegawa; H Nishibori; T Endo; M Kitajima
Journal:  Surg Endosc       Date:  2006-06-08       Impact factor: 4.584

2.  New laparoscopic double-stapling technique.

Authors:  Madoka Hamada; Yutaka Nishioka; Yohei Kurose; Takao Nishimura; Yoshihito Furukita; Kazuhide Ozaki; Toshio Nakamura; Yasuo Fukui; Toshikatsu Taniki; Tadashi Horimi
Journal:  Dis Colon Rectum       Date:  2007-12       Impact factor: 4.585

3.  Relationship between multiple numbers of stapler firings during rectal division and anastomotic leakage after laparoscopic rectal resection.

Authors:  Masaaki Ito; Masanori Sugito; Akihiro Kobayashi; Yusuke Nishizawa; Yoshiyuki Tsunoda; Norio Saito
Journal:  Int J Colorectal Dis       Date:  2008-04-01       Impact factor: 2.571

4.  Rectal transection by the Nelaton catheter pulling method during a laparoscopic low anterior resection.

Authors:  Tsukasa Hotta; Katsunari Takifuji; Shozo Yokoyama; Kenji Matsuda; Yoshimasa Oku; Tadamichi Hashimoto; Naoyuki Yamamoto; Hiroki Yamaue
Journal:  Dis Colon Rectum       Date:  2011-04       Impact factor: 4.585

5.  Rectal washout and local recurrence of cancer after anterior resection.

Authors:  K Kodeda; E Holmberg; F Jörgren; S Nordgren; G Lindmark
Journal:  Br J Surg       Date:  2010-10       Impact factor: 6.939

6.  Endo-satinsky clamp for rectal transection during laparoscopic total mesorectal excision.

Authors:  Sun Jin Park; Sung Il Choi; Suk Hwan Lee; Kil Yeon Lee
Journal:  Dis Colon Rectum       Date:  2010-03       Impact factor: 4.585

7.  Laparoscopic low rectal anastomosis using a new stapling device: early experience with the Contour stapler.

Authors:  E M Targarona; C Balague; C Martinez; M P Hernandez; M Trias
Journal:  Minim Invasive Ther Allied Technol       Date:  2008       Impact factor: 2.442

8.  Laparoscopic-assisted anterior resection with double-stapling technique anastomosis: safe and feasible for lower rectal cancer?

Authors:  Hiroya Kuroyanagi; Takashi Akiyoshi; Masatoshi Oya; Yoshiya Fujimoto; Masashi Ueno; Toshiharu Yamaguchi; Tetsuichiro Muto
Journal:  Surg Endosc       Date:  2008-12-31       Impact factor: 4.584

  8 in total
  1 in total

1.  Laparoscopic use of the Contour® Curved Cutter Stapler device via a glove port: a modified technique.

Authors:  R Oliphant; G Richardson; A Keshava
Journal:  Tech Coloproctol       Date:  2016-11-25       Impact factor: 3.781

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.