Literature DB >> 18609003

Laparoscopic low rectal anastomosis using a new stapling device: early experience with the Contour stapler.

E M Targarona1, C Balague, C Martinez, M P Hernandez, M Trias.   

Abstract

Rectal cancer was initially considered a contraindication for the laparoscopic approach to low rectal resection due to the greater difficulty of deep pelvic dissection, but several studies have demonstrated its potential clinical advantages. The currently accepted technique for this intervention includes total mesorectal excision, which entails complete dissection of the mesorectum followed by low transection of the rectum. The laparoscopic approach provides good visualization and magnification of the operative field, but transection of the rectum may be more difficult. This is illustrated by the conversion rate of around 15% in most series, mainly due to technical difficulties. Contour placement may overcome these difficulties. Two key points support the interest in the use of devices with the features of the Contour. First, the current feeling and evidence indicate that with presently available laparoscopic devices, the section of the low rectum in selected patients (males and mid-third rectal tumors) is often difficult. Secondly, although the Contour device was designed for open surgery, surgeons have the intuitive perception that it perfectly accomplishes the functions an ideal laparoscopic stapler should include. There is clearly a need for more appropriate laparoscopic instruments for low rectal transection. The Contour device could be considered a prototype because it meets the surgeon's requirements when operating on the low rectum, providing one shot, simultaneous sewing and cutting function and a symmetric rectum section. However, a number of technical modifications would enhance the utility of the instrument in this setting.

Entities:  

Mesh:

Year:  2008        PMID: 18609003     DOI: 10.1080/13645700802103340

Source DB:  PubMed          Journal:  Minim Invasive Ther Allied Technol        ISSN: 1364-5706            Impact factor:   2.442


  2 in total

1.  Rectal transection using a curved cutter stapler with an endo-Satinsky clamp during a laparoscopic low anterior resection.

Authors:  Tsukasa Hotta; Katsunari Takifuji; Shozo Yokoyama; Kenji Matsuda; Hiroki Yamaue
Journal:  Langenbecks Arch Surg       Date:  2012-05-03       Impact factor: 3.445

2.  Association of Complications with Healthcare Utilization and Hospital-Borne Costs Among Patients Undergoing Open Low Anterior Resection Using Curved Cutter Staplers.

Authors:  Pragya Rai; Stephen S Johnston; Rusha Chaudhuri; Elena Naoumtchik; Esther Pollack
Journal:  Med Devices (Auckl)       Date:  2021-03-31
  2 in total