Literature DB >> 22547276

Harmonic spatial coherence imaging: an ultrasonic imaging method based on backscatter coherence.

Jeremy Dahl1, Marko Jakovljevic, Gianmarco F Pinton, Gregg E Trahey.   

Abstract

We introduce a harmonic version of the short-lag spatial coherence (SLSC) imaging technique, called harmonic spatial coherence imaging (HSCI). The method is based on the coherence of the second-harmonic backscatter. Because the same signals that are used to construct harmonic B-mode images are also used to construct HSCI images, the benefits obtained with harmonic imaging are also obtained with HSCI. Harmonic imaging has been the primary tool for suppressing clutter in diagnostic ultrasound imaging, however secondharmonic echoes are not necessarily immune to the effects of clutter. HSCI and SLSC imaging are less sensitive to clutter because clutter has low spatial coherence. HSCI shows favorable imaging characteristics such as improved contrast-to-noise ratio (CNR), improved speckle SNR, and better delineation of borders and other structures compared with fundamental and harmonic B-mode imaging. CNRs of up to 1.9 were obtained from in vivo imaging of human cardiac tissue with HSCI, compared with 0.6, 0.9, and 1.5 in fundamental B-mode, harmonic B-mode, and SLSC imaging, respectively. In vivo experiments in human liver tissue demonstrated SNRs of up to 3.4 for HSCI compared with 1.9 for harmonic B-mode. Nonlinear simulations of a heart chamber model were consistent with the in vivo experiments.

Entities:  

Mesh:

Year:  2012        PMID: 22547276      PMCID: PMC3342045          DOI: 10.1109/TUFFC.2012.2243

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  27 in total

1.  Adaptive imaging using the generalized coherence factor.

Authors:  Pai-Chi Li; Meng-Lin Li
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-02       Impact factor: 2.725

2.  Spatial and temporal aberrator stability for real-time adaptive imaging.

Authors:  Jeremy J Dahl; Mary S Soo; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-09       Impact factor: 2.725

3.  Finite amplitude distortion-based inhomogeneous pulse echo ultrasonic imaging.

Authors:  T Christopher
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1997       Impact factor: 2.725

4.  Time reversal of ultrasonic fields. I. Basic principles.

Authors:  M Fink
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

5.  Speckle coherence and implications for adaptive imaging.

Authors:  W F Walker; G E Trahey
Journal:  J Acoust Soc Am       Date:  1997-04       Impact factor: 1.840

6.  Effect of obesity on image quality: fifteen-year longitudinal study for evaluation of dictated radiology reports.

Authors:  Raul N Uppot; Dushyant V Sahani; Peter F Hahn; Mannudeep K Kalra; Sanjay S Saini; Peter R Mueller
Journal:  Radiology       Date:  2006-06-26       Impact factor: 11.105

7.  Factors affecting image quality and diagnostic efficacy in abdominal sonography: a prospective study of 140 patients.

Authors:  A Shmulewitz; S A Teefey; B S Robinson
Journal:  J Clin Ultrasound       Date:  1993 Nov-Dec       Impact factor: 0.910

8.  Sources of image degradation in fundamental and harmonic ultrasound imaging: a nonlinear, full-wave, simulation study.

Authors:  Gianmarco F Pinton; Gregg E Trahey; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-06       Impact factor: 2.725

9.  The impact of maternal obesity on satisfactory detailed anatomic ultrasound image acquisition.

Authors:  Fadi R Khoury; Hugh M Ehrenberg; Brian M Mercer
Journal:  J Matern Fetal Neonatal Med       Date:  2009-04

10.  A heterogeneous nonlinear attenuating full-wave model of ultrasound.

Authors:  Gianmarco F Pinton; Jeremy Dahl; Stephen Rosenzweig; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-03       Impact factor: 2.725

View more
  23 in total

1.  Synthetic aperture focusing for short-lag spatial coherence imaging.

Authors:  Nick Bottenus; Brett C Byram; Jeremy J Dahl; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-09       Impact factor: 2.725

2.  Frequency-sum beamforming for passive cavitation imaging.

Authors:  Shima H Abadi; Kevin J Haworth; Karla P Mercado-Shekhar; David R Dowling
Journal:  J Acoust Soc Am       Date:  2018-07       Impact factor: 1.840

3.  Coherent flow power Doppler (CFPD): flow detection using spatial coherence beamforming.

Authors:  You Leo Li; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-06       Impact factor: 2.725

4.  Effects of dual apodization with cross-correlation on tissue harmonic and pulse inversion harmonic imaging in the presence of phase aberration.

Authors:  Junseob Shin; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-03       Impact factor: 2.725

5.  Visualization of Small-Diameter Vessels by Reduction of Incoherent Reverberation With Coherent Flow Power Doppler.

Authors:  You Leo Li; Dongwoon Hyun; Lotfi Abou-Elkacem; Juergen Karl Willmann; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-11       Impact factor: 2.725

6.  Coherence-based quantification of acoustic clutter sources in medical ultrasound.

Authors:  James Long; Will Long; Nick Bottenus; Gregg Trahey
Journal:  J Acoust Soc Am       Date:  2020-08       Impact factor: 1.840

7.  Improved Sensitivity in Ultrasound Molecular Imaging With Coherence-Based Beamforming.

Authors:  Dongwoon Hyun; Lotfi Abou-Elkacem; Valerie A Perez; Sayan Mullick Chowdhury; Juergen K Willmann; Jeremy J Dahl
Journal:  IEEE Trans Med Imaging       Date:  2018-01       Impact factor: 10.048

8.  In vivo application of short-lag spatial coherence and harmonic spatial coherence imaging in fetal ultrasound.

Authors:  Vaibhav Kakkad; Jeremy Dahl; Sarah Ellestad; Gregg Trahey
Journal:  Ultrason Imaging       Date:  2014-08-12       Impact factor: 1.578

9.  Short-lag spatial coherence imaging on matrix arrays, part 1: Beamforming methods and simulation studies.

Authors:  Dongwoon Hyun; Gregg E Trahey; Marko Jakovljevic; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-07       Impact factor: 2.725

10.  In vivo application of short-lag spatial coherence imaging in human liver.

Authors:  Marko Jakovljevic; Gregg E Trahey; Rendon C Nelson; Jeremy J Dahl
Journal:  Ultrasound Med Biol       Date:  2013-01-21       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.