Literature DB >> 22538132

Accessibility attributes of blood glucose meter and home blood pressure monitor displays for visually impaired persons.

Morgan V Blubaugh1, Mark M Uslan.   

Abstract

The vast majority of diabetes-related self-management technology utilizes small visual displays (SVDs) that often produce a low level of contrast and suffer from high levels of reflection (glare). This is a major accessibility issue for the 3.5 million Americans with diabetes who have reduced vision. The purpose of this article is to gather comparative data on the key display attributes of the SVDs used in blood glucose meters (BGMs) and home blood pressure monitors (HBPMs) on the market today and determine which displays offer the best prospect for being accessible to people with reduced vision. Nine BGMs and eight HBPMs were identified for this study on the basis of amount of devices sold, fullfunctionality speech output, and advanced display technologies. An optical instrumentation system obtained contrast, reflection (glare), and font height measurements for all 17 displays. The contrast, reflection, and font-height values for the BGMs and HBPMs varied greatly between models. The Michelson contrast values for the BGMs ranged from 11% to 98% and font heights ranged 0.39-1.00 in. for the measurement results. The HBPMs had Michelson contrast values ranging 55-96% and font height ranging 0.28-0.94 in. for the measurement results. Due largely to the lack of display design standards for the technical requirements of SVDs, there is tremendous variability in the quality and readability of BGM and HBPM displays. There were two BGMs and one HBPM that exhibited high-contrast values and large font heights, but most of the devices exhibited either poor contrast or exceptionally high reflection.
© 2012 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22538132      PMCID: PMC3380764          DOI: 10.1177/193229681200600206

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  7 in total

Review 1.  Standards of medical care in diabetes--2012.

Authors: 
Journal:  Diabetes Care       Date:  2012-01       Impact factor: 19.112

2.  Summary health statistics for U.S. adults: National Health Interview Survey, 2008.

Authors:  John R Pleis; Jacqueline W Lucas; Brian W Ward
Journal:  Vital Health Stat 10       Date:  2009-12

3.  Spatial frequency sensitivity differences between adults of good and poor reading ability.

Authors:  Geoffrey R Patching; Timothy R Jordan
Journal:  Invest Ophthalmol Vis Sci       Date:  2005-06       Impact factor: 4.799

4.  Blood glucose meters and accessibility to blind and visually impaired people.

Authors:  Darren M Burton; Matthew G Enigk; John W Lilly
Journal:  J Diabetes Sci Technol       Date:  2012-03-01

5.  Accessibility of home blood pressure monitors for blind and visually impaired people.

Authors:  Mark M Uslan; Darren M Burton; Thomas E Wilson; Steven Taylor; Bruce S Chertow; Jack E Terry
Journal:  J Diabetes Sci Technol       Date:  2007-03

6.  Psychophysics of reading. VI--The role of contrast in low vision.

Authors:  G S Rubin; G E Legge
Journal:  Vision Res       Date:  1989       Impact factor: 1.886

7.  Characteristics of AMD patients with low vision receiving visual rehabilitation.

Authors:  R A Schuchard; S Naseer; K de Castro
Journal:  J Rehabil Res Dev       Date:  1999-10
  7 in total
  1 in total

Review 1.  Usability of Medical Devices for Patients With Diabetes Who Are Visually Impaired or Blind.

Authors:  Lutz Heinemann; Diana Drossel; Guido Freckmann; Bernhard Kulzer
Journal:  J Diabetes Sci Technol       Date:  2016-11-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.