Pressurisation leads to better cement penetration into the glenoid bone: a cadaveric study.

P Raiss1, B Sowa, T Bruckner, S Eck, S Woerz, K Rohr, M Rickert, P Kasten.   

Abstract

The aim of this study was to compare a third-generation cementing procedure for glenoid components with a new technique for cement pressurisation. In 20 pairs of scapulae, 20 keeled and 20 pegged glenoid components were implanted using either a third-generation cementing technique (group 1) or a new pressuriser (group 2). Cement penetration was measured by three-dimensional (3D) analysis of micro-CT scans. The mean 3D depth of penetration of the cement was significantly greater in group 2 (p < 0.001). The mean thickness of the cement mantle for keeled glenoids was 2.50 mm (2.0 to 3.3) in group 1 and 5.18 mm (4.4 to 6.1) in group 2, and for pegged glenoids it was 1.72 mm (0.9 to 2.3) in group 1 and 5.63 mm (3.6 to 6.4) in group 2. A cement mantle < 2 mm was detected less frequently in group 2 (p < 0.001). Using the cement pressuriser the proportion of cement mantles < 2 mm was significantly reduced compared with the third-generation cementing technique.

Mesh:

Substances:

Year:  2012        PMID: 22529090     DOI: 10.1302/0301-620X.94B5.28831

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  6 in total

1.  [Glenoid replacement for omarthritis : indications, technique, results and new developments].

Authors:  M Pfahler
Journal:  Orthopade       Date:  2013-07       Impact factor: 1.087

2.  Effect of glenoid perforation during total shoulder arthroplasty on glenoid component cement fixation and suprascapular nerve.

Authors:  Gregory I Pace; Rachel A Thomas; Connor L Zale; Gregory S Lewis; Raymond Y Kim; H Mike Kim
Journal:  Shoulder Elbow       Date:  2020-01-13

3.  Total shoulder replacement using a bone ingrowth central peg polyethylene glenoid component: a prospective clinical and computed tomography study with short- to mid-term follow-up.

Authors:  Giovanni Merolla; Giovanni Ciaramella; Elisabetta Fabbri; Gilles Walch; Paolo Paladini; Giuseppe Porcellini
Journal:  Int Orthop       Date:  2016-08-10       Impact factor: 3.075

4.  Computed tomography quantification of bone density adjacent to cemented pegged polyethylene glenoid components in shoulder arthroplasty.

Authors:  Giovanni Merolla; Barbara Amore; Paolo Paladini; Enrico Cavagna; Giuseppe Porcellini
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-11-26

5.  Cement pressurizing reduces radiolucent lines at glenoid: A randomized, multicentric study.

Authors:  Philip Kasten; Patric Raiss; Felix Zeifang; Richard Stangl; Stefan Greiner; Matthias Zumstein; Jörg Nowotny; Katrin Schmitt; Marc Schnetzke; Falk Reuther; Dirk Frauenschuh
Journal:  Shoulder Elbow       Date:  2019-08-01

6.  An in vitro study comparing limited to full cementation of polyethylene glenoid components.

Authors:  R Andrew Glennie; Joshua W Giles; James A Johnson; George S Athwal; Kenneth J Faber
Journal:  J Orthop Surg Res       Date:  2015-09-17       Impact factor: 2.359