Literature DB >> 22523931

Blood loss following total knee replacement is reduced when using computer-assisted versus standard methods.

Jamie McConnell1, John Dillon, Andrew Kinninmonth, Martin Sarungi, Frederic Picard.   

Abstract

Perioperative blood loss was compared in 136 patients (2 groups of 68 patients) who underwent total knee arthroplasty (TKA). Blood loss was significantly lower when using a computer-navigated technique in comparison to a method employing intramedullary femoral rods. Total blood loss was calculated from body weight, height and haematocrit change, using a model that has been shown to reliably estimate true blood loss. Average total blood loss was 1362 ml in the standard TKA group, and 1137 ml in the computer navigated TKA group. This difference was statistically significant (p = 0.016). This study, as compared to previous papers assessing the effects of navigation, used a larger sample size and a more reliable method of assessing blood loss, which takes account of "hidden" losses, and confirms their findings.

Entities:  

Mesh:

Year:  2012        PMID: 22523931

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  17 in total

Review 1.  Computer Assisted Total Knee Arthroplasty: Does it Make a Difference?

Authors:  Emil G Haritinian; Ashvin L Pimpalnerkar
Journal:  Maedica (Buchar)       Date:  2013-06

Review 2.  Patient specific instrumentation in total knee arthroplasty: a state of the art.

Authors:  Lorenzo Mattei; Pietro Pellegrino; Michel Calò; Alessandro Bistolfi; Filippo Castoldi
Journal:  Ann Transl Med       Date:  2016-04

3.  Inconsistencies between navigation data and radiographs in total knee arthroplasty are system-dependent and affect coronal alignment.

Authors:  Alberto Carli; Ahmed Aoude; Avishai Reuven; Bogdan Matache; John Antoniou; David J Zukor
Journal:  Can J Surg       Date:  2014-10       Impact factor: 2.089

Review 4.  Current state of the art in total knee arthroplasty computer navigation.

Authors:  Frederic Picard; Kamal Deep; Jean Yves Jenny
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-10-04       Impact factor: 4.342

5.  Computer navigation is effective in reducing blood loss but has no effect on transfusion requirement following primary total knee arthroplasty: a meta-analysis.

Authors:  Seung-Beom Han; Hyun-Jung Kim; Tae-Kyun Kim; Yong In; Kwang-Jun Oh; In-Jun Koh; Dae-Hee Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-02-27       Impact factor: 4.342

Review 6.  [Update on navigation in total knee arthroplasty. Where are we today and what lies in the future?].

Authors:  T Renkawitz; S Winkler; M Weber; F von Kunow; J Grifka; C Baier
Journal:  Orthopade       Date:  2014-05       Impact factor: 1.087

Review 7.  Total knee arthroplasties from the origin to navigation: history, rationale, indications.

Authors:  Dominique Saragaglia; Brice Rubens-Duval; Julia Gaillot; Gabriel Lateur; Régis Pailhé
Journal:  Int Orthop       Date:  2018-03-27       Impact factor: 3.075

8.  Is TKA with computer-assisted navigation associated with less blood loss? A comparative study between computer-navigated and conventional method.

Authors:  Diamantis Mitsiou; Emilios E Pakos; Dimitrios V Papadopoulos; Giorgos Georgiadis; Ioannis D Gelalis; Andreas G Tsantes; Ioannis Gkiatas; Nikos Kalos; Theodoros A Xenakis
Journal:  J Orthop       Date:  2020-01-13

9.  The use of patient-specific instruments does not reduce blood loss during minimally invasive total knee arthroplasty?

Authors:  Emmanuel Thienpont; Irina Grosu; Frederic Paternostre; Pierre-Emmanuel Schwab; Jean Cyr Yombi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-03-27       Impact factor: 4.342

10.  No difference between computer-assisted and conventional total knee arthroplasty: five-year results of a prospective randomised study.

Authors:  Jörg Lützner; Julian Dexel; Stephan Kirschner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-07-14       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.