Literature DB >> 22520428

Influence of geometrical parameters on radial force during self-expanding stent deployment. Application for a variable radial stiffness stent.

A García1, E Peña, M A Martínez.   

Abstract

The goal of this work is to study the influence of the main geometrical parameters on the radial force of a self-expanding stent, and using them to advance towards a new design of a variable radial force stent to improve the interaction vessel-device. Using finite element simulations, a parametric analysis of a commercial stent model (Acculink, Abbot Vascular) was developed to estimate the influence of geometrical variables, mainly radial and circumferential strut thicknesses and the initial diameter of the stent. The radial expansion force was compared for the different values of each geometrical variable. The previous results were used to propose a new stent design with variable radial stiffness. Their effects on healthy and atheromatous vessels were studied and compared for both stent models, constant and variable radial stiffness respectively. The developed analysis reveals a notable decrease of the contact pressure over the inner arterial wall in healthy areas using a variable radial force (VF) stent with respect to the same model with a constant expansion force (CF) stent. In the case of a vessel model with a fibrotic core plaque, the lumen healthy areas that suffer a contact pressure higher than 0.25 MPa are reduced from 36.86% to 22.38% for the left healthy area (LHA), and from 40.13% to 21.36% in the right healthy area (RHA). Furthermore, this pressure reduction in the healthy areas does not cause a decrease in the expansion pressure in an atheromatous section, where it is necessary to maintain a recovery of the lumen section. In the case of lipid core, the flow section with plaque is 70.8% of the healthy flow section using a VF stent, and 70.9% with a CF stent, while 66.87% and 66.89% were found respectively in the case of a calcified core.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22520428     DOI: 10.1016/j.jmbbm.2012.02.006

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  10 in total

1.  Carotid endarterectomy versus stenting: Does the flow really change? An Echo-Color-Doppler analysis.

Authors:  Pierleone Lucatelli; Fabrizio Fanelli; Carlo Cirelli; Beatrice Sacconi; Michele Anzidei; Roberto Montisci; Roberto Sanfilippo; Elisabetta Tamponi; Carlo Catalano; Luca Saba
Journal:  Int J Cardiovasc Imaging       Date:  2015-02-20       Impact factor: 2.357

2.  Mathematical modelling of the restenosis process after stent implantation.

Authors:  Javier Escuer; Miguel A Martínez; Sean McGinty; Estefanía Peña
Journal:  J R Soc Interface       Date:  2019-08-14       Impact factor: 4.118

3.  Cross-sectional pinching in human femoropopliteal arteries due to limb flexion, and stent design optimization for maximum cross-sectional opening and minimum intramural stresses.

Authors:  Anastasia Desyatova; William Poulson; Jason MacTaggart; Kaspars Maleckis; Alexey Kamenskiy
Journal:  J R Soc Interface       Date:  2018-08       Impact factor: 4.118

Review 4.  Microstructure-based biomechanics of coronary arteries in health and disease.

Authors:  Huan Chen; Ghassan S Kassab
Journal:  J Biomech       Date:  2016-03-20       Impact factor: 2.712

5.  Realistic computer modelling of stent retriever thrombectomy: a hybrid finite-element analysis-smoothed particle hydrodynamics model.

Authors:  S Mostafa Mousavi J S; Danial Faghihi; Kelsey Sommer; Mohammad M S Bhurwani; Tatsat R Patel; Briana Santo; Muhammad Waqas; Ciprian Ionita; Elad I Levy; Adnan H Siddiqui; Vincent M Tutino
Journal:  J R Soc Interface       Date:  2021-12-15       Impact factor: 4.118

6.  A Computational Framework Examining the Mechanical Behaviour of Bare and Polymer-Covered Self-Expanding Laser-Cut Stents.

Authors:  Ciara G McKenna; Ted J Vaughan
Journal:  Cardiovasc Eng Technol       Date:  2021-11-30       Impact factor: 2.305

7.  In silico assessment of the effects of material on stent deployment.

Authors:  Georgia S Karanasiou; Nikolaos S Tachos; Antonios Sakellarios; Lampros K Michalis; Claire Conway; Elazer R Edelman; Dimitrios I Fotiadis
Journal:  Proc IEEE Int Symp Bioinformatics Bioeng       Date:  2018-01-11

8.  Mechanical response of cardiovascular stents under vascular dynamic bending.

Authors:  Jiang Xu; Jie Yang; Nan Huang; Christopher Uhl; Yihua Zhou; Yaling Liu
Journal:  Biomed Eng Online       Date:  2016-02-20       Impact factor: 2.819

9.  Multi-objective optimisation of material properties and strut geometry for poly(L-lactic acid) coronary stents using response surface methodology.

Authors:  Ross W Blair; Nicholas J Dunne; Alex B Lennon; Gary H Menary
Journal:  PLoS One       Date:  2019-08-26       Impact factor: 3.240

10.  Evaluation of a New Approach for Modeling Full Ring Stent Bundles with the Inclusion of Manufacturing Strains.

Authors:  Faidon Kyriakou; David Bow; William Dempster; Robbie Brodie; David Nash
Journal:  Ann Biomed Eng       Date:  2019-07-17       Impact factor: 3.934

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.