Literature DB >> 30079407

In silico assessment of the effects of material on stent deployment.

Georgia S Karanasiou1, Nikolaos S Tachos2, Antonios Sakellarios3, Lampros K Michalis4, Claire Conway5, Elazer R Edelman6, Dimitrios I Fotiadis7.   

Abstract

Coronary stents are expandable scaffolds that are used to widen occluded diseased arteries and restore blood flow. Because of the strain they are exposed to and forces they must resist as well as the importance of surface interactions, material properties are dominant. Indeed, a common differentiating factors amongst commercially available stents is their material. Several performance requirements relate to stent materials including radial strength for adequate arterial support post-deployment. This study investigated the effect of the stent material in three finite element models using different stents made of: (i) Cobalt-Chromium (CoCr), (ii) Stainless Steel (SS316L), and (iii) Platinum Chromium (PtCr). Deployment was investigated in a patient specific arterial geometry, created based on a fusion of angiographic data and intravascular ultrasound images. In silico results show that: (i) the maximum von Mises stress occurs for the CoCr, however the curved areas of the stent links present higher stresses compared to the straight stent segments for all stents, (ii) more areas of high inner arterial stress exist in the case of the CoCr stent deployment, (iii) there is no significant difference in the percentage of arterial stress volume distribution among all models.

Entities:  

Keywords:  finite element model; material; mathematical model; stent

Year:  2018        PMID: 30079407      PMCID: PMC6069522          DOI: 10.1109/BIBE.2017.00-11

Source DB:  PubMed          Journal:  Proc IEEE Int Symp Bioinformatics Bioeng


  21 in total

Review 1.  Computational structural modelling of coronary stent deployment: a review.

Authors:  David Martin; Fergal J Boyle
Journal:  Comput Methods Biomech Biomed Engin       Date:  2011-04       Impact factor: 1.763

2.  Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs.

Authors:  Gerhard A Holzapfel; Michael Stadler; Thomas C Gasser
Journal:  J Biomech Eng       Date:  2005-02       Impact factor: 2.097

3.  The influence of plaque composition on underlying arterial wall stress during stent expansion: the case for lesion-specific stents.

Authors:  Ian Pericevic; Caitríona Lally; Deborah Toner; Daniel John Kelly
Journal:  Med Eng Phys       Date:  2009-01-06       Impact factor: 2.242

4.  On the effects of different strategies in modelling balloon-expandable stenting by means of finite element method.

Authors:  Francesca Gervaso; Claudio Capelli; Lorenza Petrini; Simone Lattanzio; Luca Di Virgilio; Francesco Migliavacca
Journal:  J Biomech       Date:  2008       Impact factor: 2.712

5.  Realistic finite element-based stent design: the impact of balloon folding.

Authors:  Matthieu De Beule; Peter Mortier; Stéphane G Carlier; Benedict Verhegghe; Rudy Van Impe; Pascal Verdonck
Journal:  J Biomech       Date:  2007-10-24       Impact factor: 2.712

6.  Geometry parameterization and multidisciplinary constrained optimization of coronary stents.

Authors:  Sanjay Pant; Neil W Bressloff; Georges Limbert
Journal:  Biomech Model Mechanobiol       Date:  2011-03-04

Review 7.  Global Overview of the Epidemiology of Atherosclerotic Cardiovascular Disease.

Authors:  Simon Barquera; Andrea Pedroza-Tobías; Catalina Medina; Lucía Hernández-Barrera; Kirsten Bibbins-Domingo; Rafael Lozano; Andrew E Moran
Journal:  Arch Med Res       Date:  2015-06-29       Impact factor: 2.235

Review 8.  Apolipoprotein A-I/HDL infusion therapy for plaque stabilization-regression: a novel therapeutic approach.

Authors:  P K Shah
Journal:  Curr Pharm Des       Date:  2007       Impact factor: 3.116

9.  A numerical model to study the interaction of vascular stents with human atherosclerotic lesions.

Authors:  Dimitrios E Kiousis; T Christian Gasser; Gerhard A Holzapfel
Journal:  Ann Biomed Eng       Date:  2007-07-24       Impact factor: 3.934

10.  Simulation of stent deployment in a realistic human coronary artery.

Authors:  Frank J H Gijsen; Francesco Migliavacca; Silvia Schievano; Laura Socci; Lorenza Petrini; Attila Thury; Jolanda J Wentzel; Anton F W van der Steen; Patrick W S Serruys; Gabriele Dubini
Journal:  Biomed Eng Online       Date:  2008-08-06       Impact factor: 2.819

View more
  1 in total

1.  A Three-Dimensional Finite Element Analysis of Aramany Class I Obturator Fabricated with Different Alloys.

Authors:  Kashinath C Arabbi; Takshil D Shah; Mahantesha Sharanappa; Shobha K Subbaiah
Journal:  J Pharm Bioallied Sci       Date:  2019-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.