Wear performance of dental ceramics after grinding and polishing treatments.

Verena Preis1, Michael Behr, Gerhard Handel, Sibylle Schneider-Feyrer, Sebastian Hahnel, Martin Rosentritt.   

Abstract

AIM: The aim of this in vitro study was to determine the two-body wear resistance of different dental ceramics after grinding and polishing treatments.
MATERIAL AND METHODS: Standardized specimens were prepared from three zirconia and two veneering ceramics and were subjected to different surface treatments. Zirconia ceramics were polished, ground and repolished, veneering ceramics were ground and repolished. One zirconia ceramic was investigated with a superficial glaze. Human enamel was used for reference. Surface roughness R(a) was determined using a profilometric contact surface measurement device. Two-body wear tests were performed in a chewing simulator with steatite and enamel antagonists, respectively. Specimens were loaded pneumatically in a pin-on-block design for 1.2x10(5) mastication cycles (50 N, 1.2 Hz, lateral movement: 1 mm, mouth opening: 2 mm) under simultaneous thermal cycling (600 cycles, 5/55 °C). Wear depths of specimens were determined using a 3D laser scanning device, wear areas of steatite antagonists were measured by means of light-optical micrographs. Means and standard deviations were calculated, and statistical analysis was performed using one-way analysis of variance (ANOVA) and the Bonferroni multiple comparison test for post hoc analysis (α=0.05). Scanning electron microscopy was applied for evaluating the wear performance of ceramics and antagonists.
RESULTS: No wear was found for polished, ground and repolished zirconia. Compared to the wear depths of the enamel reference with 274.1±187.4 μm versus steatite and 123.3±131.0 μm versus enamel, relative wear depths of porcelains ranged between 0.54±0.07 and 0.62±0.09 with steatite antagonists and between 0.66±0.26 and 1.04±0.27 with enamel antagonists. Relative wear areas of steatite antagonists (enamel reference: 1.25 mm(2)) varied between 0.84±0.13 and 1.90±0.29 for zirconia and between 1.97±0.38 and 2.47±0.40 for porcelains. Enamel antagonists generally showed wear, cracks or even fractures, but revealed smooth surfaces when opposed to polished/ground/repolished zirconia and ploughed surfaces when opposed to ground/repolished porcelains or glaze.
CONCLUSIONS: Zirconia ceramics yielded superior wear behavior and lower antagonistic wear compared to porcelains. A trend to higher ceramic and antagonistic wear was shown after grinding treatments.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22520415     DOI: 10.1016/j.jmbbm.2012.03.002

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  21 in total

1.  Influence of cusp inclination and curvature on the in vitro failure and fracture resistance of veneered zirconia crowns.

Authors:  Verena Preis; Thomas Dowerk; Michael Behr; Carola Kolbeck; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2013-07-12       Impact factor: 3.573

2.  Surface roughness and wear behavior of occlusal splint materials made of contemporary and high-performance polymers.

Authors:  Merve Benli; Beril Eker Gümüş; Yusuf Kahraman; Bilge Gökçen-Rohlig; Gülümser Evlioğlu; Olivier Huck; Mutlu Özcan
Journal:  Odontology       Date:  2019-10-14       Impact factor: 2.634

3.  Polishing effects and wear performance of chairside CAD/CAM materials.

Authors:  Mike Matzinger; Sebastian Hahnel; Verena Preis; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2018-05-16       Impact factor: 3.573

4.  Effect of finishing/polishing techniques and low temperature degradation on the surface topography, phase transformation and flexural strength of ultra-translucent ZrO2 ceramic.

Authors:  Taciana Emília Leite Vila-Nova; Isabelle Helena Gurgel de Carvalho; Dayanne Monielle Duarte Moura; André Ulisses Dantas Batista; Yu Zhang; Carlos Alberto Paskocimas; Marco Antonio Bottino; Rodrigo Othávio de Assunção E Souza
Journal:  Dent Mater       Date:  2020-01-31       Impact factor: 5.304

5.  Antagonist wear of monolithic zirconia crowns after 2 years.

Authors:  Ulrich Lohbauer; Sven Reich
Journal:  Clin Oral Investig       Date:  2016-06-09       Impact factor: 3.573

6.  Novel Testing for Corrosion of Glass-Ceramics for Dental Applications.

Authors:  J F Esquivel-Upshaw; F Ren; S M Hsu; F Y Dieng; D Neal; A E Clark
Journal:  J Dent Res       Date:  2017-09-18       Impact factor: 6.116

7.  Wear behavior of pressable lithium disilicate glass ceramic.

Authors:  Zhongxiao Peng; Muhammad Izzat Abdul Rahman; Yu Zhang; Ling Yin
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2015-05-15       Impact factor: 3.368

8.  Wear behavior and abrasiveness of monolithic CAD/CAM ceramics after simulated mastication.

Authors:  Ahmed Mahmoud Fouda; Osama Atta; Amr Shebl Kassem; Mohamed Desoky; Christoph Bourauel
Journal:  Clin Oral Investig       Date:  2022-07-11       Impact factor: 3.606

9.  The effect of adjustment and finishing procedure on roughness, strength, and phase transformation of monolithic zirconia.

Authors:  Isıl Ozturk; Ipek Caglar; Zeynep Yesil Duymus
Journal:  Clin Oral Investig       Date:  2022-03-16       Impact factor: 3.606

10.  Maxillary cement retained implant supported monolithic zirconia prosthesis in a full mouth rehabilitation: a clinical report.

Authors:  Ramtin Sadid-Zadeh; Perng-Ru Liu; Ruth Aponte-Wesson; Sandra J O'Neal
Journal:  J Adv Prosthodont       Date:  2013-05-30       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.