Literature DB >> 22517477

Free-breathing 3D whole-heart black-blood imaging with motion sensitized driven equilibrium.

Subashini Srinivasan1, Peng Hu, Kraig V Kissinger, Beth Goddu, Lois Goepfert, Ehud J Schmidt, Sebastian Kozerke, Reza Nezafat.   

Abstract

PURPOSE: To assess the efficacy and robustness of motion sensitized driven equilibrium (MSDE) for blood suppression in volumetric 3D whole-heart cardiac MR.
MATERIALS AND METHODS: To investigate the efficacy of MSDE on blood suppression and myocardial signal-to-noise ratio (SNR) loss on different imaging sequences, seven healthy adult subjects were imaged using 3D electrocardiogram (ECG)-triggered MSDE-prep T(1) -weighted turbo spin echo (TSE), and spoiled gradient echo (GRE), after optimization of MSDE parameters in a pilot study of five subjects. Imaging artifacts, myocardial and blood SNR were assessed. Subsequently, the feasibility of isotropic spatial resolution MSDE-prep black-blood was assessed in six subjects. Finally, 15 patients with known or suspected cardiovascular disease were recruited to be imaged using a conventional multislice 2D double inversion recovery (DIR) TSE imaging sequence and a 3D MSDE-prep spoiled GRE.
RESULTS: The MSDE-prep yielded significant blood suppression (75%-92%), enabling a volumetric 3D black-blood assessment of the whole heart with significantly improved visualization of the chamber walls. The MSDE-prep also allowed successful acquisition of black-blood images with isotropic spatial resolution. In the patient study, 3D black-blood MSDE-prep and DIR resulted in similar blood suppression in left ventricle and right ventricle walls but the MSDE-prep had superior myocardial signal and wall sharpness.
CONCLUSION: MSDE-prep allows volumetric black-blood imaging of the heart.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22517477      PMCID: PMC3511905          DOI: 10.1002/jmri.23662

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  25 in total

1.  Free-breathing black-blood coronary MR angiography: initial results.

Authors:  M Stuber; R M Botnar; K V Kissinger; W J Manning
Journal:  Radiology       Date:  2001-04       Impact factor: 11.105

2.  Improved efficiency in double-inversion fast spin-echo imaging.

Authors:  Dennis L Parker; K Craig Goodrich; Marilyn Masiker; Jay S Tsuruda; Gregory L Katzman
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

3.  T1-insensitive flow suppression using quadruple inversion-recovery.

Authors:  Vasily L Yarnykh; Chun Yuan
Journal:  Magn Reson Med       Date:  2002-11       Impact factor: 4.668

4.  Volume-selective 3D turbo spin echo imaging for vascular wall imaging and distensibility measurement.

Authors:  Lindsey A Crowe; Peter Gatehouse; Guang Zhong Yang; Raad H Mohiaddin; Anitha Varghese; Clare Charrier; Jennifer Keegan; David N Firmin
Journal:  J Magn Reson Imaging       Date:  2003-05       Impact factor: 4.813

5.  Rapid extended coverage simultaneous multisection black-blood vessel wall MR imaging.

Authors:  Venkatesh Mani; Vitalii V Itskovich; Michael Szimtenings; Juan Gilberto S Aguinaldo; Daniel D Samber; Gabor Mizsei; Zahi A Fayad
Journal:  Radiology       Date:  2004-07       Impact factor: 11.105

Review 6.  Overview of MR of the heart--1986.

Authors:  C B Higgins
Journal:  AJR Am J Roentgenol       Date:  1986-05       Impact factor: 3.959

7.  Diagnosis of arrhythmogenic right ventricular dysplasia: a review.

Authors:  Hein W M Kayser; Ernst E van der Wall; Mohan U Sivananthan; Sven Plein; Timothy N Bloomer; Albert de Roos
Journal:  Radiographics       Date:  2002 May-Jun       Impact factor: 5.333

8.  Magnetic resonance imaging of aortic disease: preliminary results.

Authors:  E G Amparo; C B Higgins; W Hoddick; H Hricak; R K Kerlan; E J Ring; L Kaufman; M W Hedgecock
Journal:  AJR Am J Roentgenol       Date:  1984-12       Impact factor: 3.959

9.  Arrhythmogenic right ventricular dysplasia: ex vivo and in vivo fat detection with black-blood MR imaging.

Authors:  Ernesto Castillo; Harikrishna Tandri; E Rene Rodriguez; Khurram Nasir; Julie Rutberg; Hugh Calkins; João A C Lima; David A Bluemke
Journal:  Radiology       Date:  2004-07       Impact factor: 11.105

10.  Lipid-rich atherosclerotic plaques detected by gadofluorine-enhanced in vivo magnetic resonance imaging.

Authors:  Marc Sirol; Vitalii V Itskovich; Venkatesh Mani; Juan Gilberto S Aguinaldo; John T Fallon; Bernd Misselwitz; Hanns-Joachim Weinmann; Valentin Fuster; Jean-François Toussaint; Zahi A Fayad
Journal:  Circulation       Date:  2004-06-07       Impact factor: 29.690

View more
  5 in total

1.  Black-blood native T1 mapping: Blood signal suppression for reduced partial voluming in the myocardium.

Authors:  Sebastian Weingärtner; Nadja M Meßner; Frank G Zöllner; Mehmet Akçakaya; Lothar R Schad
Journal:  Magn Reson Med       Date:  2016-09-16       Impact factor: 4.668

2.  Black blood myocardial T2 mapping.

Authors:  Chengyan Wang; Jihye Jang; Ulf Neisius; Maryam Nezafat; Ahmed Fahmy; Jinkyu Kang; Jennifer Rodriguez; Beth Goddu; Patrick Pierce; Sophie Berg; Jue Zhang; Xiaoying Wang; Reza Nezafat
Journal:  Magn Reson Med       Date:  2018-07-29       Impact factor: 4.668

3.  Reverse double inversion-recovery: Improving motion robustness of cardiac T2 -weighted dark-blood turbo spin-echo sequence.

Authors:  Chenxi Hu; Steffen Huber; Syed R Latif; Guido Santacana-Laffitte; Hamid R Mojibian; Lauren A Baldassarre; Dana C Peters
Journal:  J Magn Reson Imaging       Date:  2017-11-07       Impact factor: 4.813

4.  Ferumoxytol enhanced black-blood cardiovascular magnetic resonance imaging.

Authors:  Kim-Lien Nguyen; Eun-Ah Park; Takegawa Yoshida; Peng Hu; J Paul Finn
Journal:  J Cardiovasc Magn Reson       Date:  2017-12-28       Impact factor: 5.364

5.  Feasibility of 3D black-blood variable refocusing angle fast spin echo cardiovascular magnetic resonance for visualization of the whole heart and great vessels in congenital heart disease.

Authors:  Markus Henningsson; Riad Abou Zahr; Adrian Dyer; Gerald F Greil; Barbara Burkhardt; Animesh Tandon; Tarique Hussain
Journal:  J Cardiovasc Magn Reson       Date:  2018-11-26       Impact factor: 5.364

  5 in total